1/37
Looks like no tags are added yet.
What does CCD stand for?
a. capture- connection device
b. charged-couple device
c. computerized capturing device
d. computer charging device
b. charged-couple device
PACS stands for
a. pictures accessed by computers
b. picture access computer system
c. picture archiving and communication system
d. patient access computer system
c. picture archiving and communication system
Which of the following refers to adding text to a digital image?
a. verbalize
b. delete
c. worklist
d. annotate
d. annotate
The histogram is used to automatically rescale the image to proper brightness. Which of the following could cause an error with the histogram analysis?
1. Incorrect algorithm
2. Positioning error
3. Centering error
a. 1,2
b. 1,3
c. 2,3
d. 1,2,3
d. 1,2,3
Thin film transistors (TFT) are found in which type of digital system
a. computed radiography
b. direct flat panel
c. CCD
d. film screen radiography
b. direct flat panel
Edge enhancement can be applied to digital images to improve which of the following:
a. the black border around the edge of the image
b. incorrect amount of mAS
c. scatter radiation
d. contrast along the edge of a structure
d. contrast along the edge of a structure
_____ releases electrons when struck by light photons and ____ releases electrons when struck by x-ray photons.
a. gadolinium oxysulfide, cesium iodide
b. amorphous silicon, amorphous selenium
c. amorphous selenium, amorphous silicon
d. silver bromide, zinc lead sulfide
b. amorphous silicon, amorphous selenium
Which of the following is true concerning direct flat panel radiography compared to indirect flat panel radiography?
a. less resolution
b. more resolution
c. more distortion
b. more resolution
What is the definition of amorphous?
a. noncrystalline state of an otherwise crystalline material
b. the process of emitting light when stimulated by x-rays
c. converting x-rays to light
d. storing electrical charge for digital viewing
a. noncrystalline state of an otherwise crystalline material
A picture archiving and communication system (PACS)/MIMPS is best defined as a;
a. computer assisted file and storage system for digital images
b. digital method of recording radiographic images
c. light stimulated method of image production
d. satellite transmission network for analog images
a. computer assisted file and storage system for digital images
A graph of signal values that corresponds to a spectrum of pixel values (gray scale) called:
a. dynamic range algorithm
b. histogram
c. bit map
d. grayscale analog
b. histogram
With either an amorphous selenium or cesium iodide amorphous silicon digital radiographic imaging, the latent image is formed as an electronic signal by;
a. an array of thin-film transistors (TFTs)
b. an array of photodiodes
c. a vidicon television camera tube
d. delayed acquisition time
a. an array of thin-film transistors (TFTs)
_____ removes superimposed structures so anatomical areas of interest are more visible
a. subtraction
b. image stitching
c. edge enhancement
d. black/white reversal
a. subtraction
_____ reverses the gray scale from the original radiograph
a. subtraction
b. image stitching
c. edge enhancement
d. black/white reversal
d. black/white reversal
___ is the formation of a long body part image from a series of overlapping of images.
a. subtraction
b. image stitching
c. edge enhancement
d. black/white reversal
b. image stitching
The technique by digital images may be transmitted over phone lines for remote viewing is termed;
a. computed radiography
b. subtraction radiology
c. teleradiography
d. information radiology
c. teleradiography
Each component making up a MIMPS/PACS or a connection in a network is called;
a. PC link
b. Node
c. LAN
d. archival medium
b. Node
Visually, dynamic range refers to which of the following:
a. number of shades of gray that can be represented
b. number of pixels in a matrix
c. the range of numbers in a computer's memory
d. the size and area of an image intensifier tube
a. number of shades of gray (or signal value) that can be represented
Detective Quantum Efficiency is a measure of the receptor's ability to create:
a. a range of numbers in a computer's memory
b. output signal that accurately represents the input signal
c. increases contrast as the edge of a structure
d. teleradiography
b. output signal that accurately represents the input signal
Use non-scintillator Direct flat panel detector will ____ resolution compared to IDFP and CR
increase
Use non-scintillator flat panel Direct detector will ___ patient dose when compared to CR
decrease
Use non-scintillator flat panel Direct detector will ___ Detective quantum efficiency (DQE) compared to CR
increase
Use flat panel detector ____ patient throughput
increases
Use digital imaging as compared to film screen imaging will ___ dynamic range
increase
Use digital imaging as compared to film screen imaging will ____ number of repeat exams
decrease

Which of these histograms has the most shades of gray?
A

Which of these histograms has the highest sampling frequency?
A

Which of these histograms has the most SNR (signal to noise ratio)?
A

Which of these histograms has the best spatial resolution?
A
Flat panel indirect digital steps are as follows:
1. scintillation phosphor (fluorescent layer) or cesium iodide or rare earth phosphor converts x-rays to light
2. amorphous silicon photoconductor (photodiode) converts light from phosphor into electrons
3. TFT
4. directly to computer for processing
Flat panel direct digital steps are as follows:
1. amorphous selenium photoconductor or photodetector converts x-rays directly into electronic signal (electrons)
2. TFT
3. directly to computer for processing
histogram
graph of the grey scales constructed of the number of pixels in the entire image having the same grey levels
dynamic range
range of shades of grey displayed by pixels
detective quantum efficiency (DQE)
measure of receptor's ability to create an output signal that accurately represents the input signal
subtraction
removes superimposed structures so anatomical area of interest is more visible
edge enhancement
improves visibility of small, high contrast structures
black/white reversal
reverses the grey scale from original radiograph
image stitching