1/61
Looks like no tags are added yet.
What is the normal pH?
7.35–7.45
What is the principal buffer of plasma?
Bicarbonate/carbonic acid buffer system (HCO₃⁻/H₂CO₃).
What is a weak/strong acid and why?
Strong acid: completely dissociates (e.g., HCl).
Weak acid: partially dissociates (e.g., carbonic acid).
Strength depends on the degree of ionization.
Why do we use HCl to adjust pH solutions?
Because it is a strong acid that dissociates completely and predictably.
Three reasons bicarbonate/carbonic acid is the best buffer system
Present in high concentration in ECF.
Lungs can regulate CO₂ rapidly.
Kidneys can regulate HCO₃⁻.
What else buffers?
Hemoglobin
Plasma proteins
Phosphate buffer
Ammonia buffer (urine)
What is the end product of aerobic respiration?
CO₂ and H₂O. CO₂ enters blood, forms carbonic acid, dissociates to H⁺ and HCO₃⁻. In lungs the reaction reverses and CO₂ is exhaled.
Why does chloride move into the cell?
To maintain electrical neutrality (chloride shift).
Where did the hydrogen end up?
Buffered primarily by hemoglobin or excreted by kidneys
What if lungs cannot remove CO₂ at rate of production?
Respiratory acidosis.
What if removal is faster than production?
Respiratory alkalosis.
First line of defence for acid-base balance?
Chemical buffers.
Kidney's role?
Reabsorb HCO₃⁻
Excrete H⁺
Generate new HCO₃⁻
Why can't passive reabsorption of HCO₃⁻ occur?
HCO₃⁻ is charged and does not readily cross cell membranes.
How much bicarbonate is reabsorbed?
About 99%.
Minimum possible urine pH?
About 4.5.
Maximum possible urine pH?
About 8.0.
Two buffering systems of urine?
Phosphate
Ammonia
Ratio of HCO₃⁻ to H₂CO₃ normally?
20:1.
Acid-base status if ratio is 30:1?
Alkalosis.
ABG reference ranges
pH: 7.35–7.45
pCO₂: 35–45 mmHg
HCO₃⁻: 22–29 mmol/L
pO₂: 85–105 mmHg
All values normal but pO₂=45 mmHg. What would you question?
Whether it is actually an arterial sample or if there was a collection/identification issue.
Partial vs full compensation for metabolic acidosis
Partial:
pH 7.25
HCO₃⁻ 15
pCO₂ 30
Full:
pH 7.36
HCO₃⁻ 15
pCO₂ 28
Body's compensation for metabolic acidosis?
Hyperventilation to lower CO₂.
Causes of metabolic acidosis?
DKA
Renal failure
Diarrhoea
Lactic acidosis
Kussmaul breathing?
Deep, rapid breathing seen in severe metabolic acidosis.
Cause of increased anion gap acidosis?
Accumulation of unmeasured acids:
Lactate
Ketones
Uraemic acids
Cause of normal anion gap acidosis?
Loss of bicarbonate: Diarrhoea
Renal tubular acidosis
Causes of respiratory acidosis?
Hypoventilation, COPD, airway obstruction, respiratory depression.
Causes of metabolic alkalosis?
Vomiting
Diuretics
Excess antacids
Compensation for metabolic alkalosis?
Hypoventilation (retain CO₂).
Causes of respiratory alkalosis?
Hyperventilation
Anxiety
Hypoxia
High altitude
How does body compensate?
Kidneys excrete bicarbonate.
Three most common causes of metabolic acidosis
Diabetic ketoacidosis
Lactic acidosis
Renal failure
Two most common causes of metabolic alkalosis
Vomiting
Diuretics
Seven requirements for adequate tissue oxygenation
Adequate ventilation
Adequate oxygen diffusion
Adequate hemoglobin
Adequate cardiac output
Normal Hb affinity
Good circulation/perfusion
Adequate oxygen saturation
What is oxygen saturation?
Percentage of hemoglobin binding sites occupied by oxygen.
How is oxygen saturation measured?
By co-oximetry or pulse oximetry.
What is FO₂Hb?
Fraction of total hemoglobin present as oxyhemoglobin.
What does hemoglobin affinity for oxygen depend on?
pH
pCO₂
Temperature
2,3-DPG
Why do smokers get more winded?
Carbon monoxide forms carboxyhemoglobin and reduces oxygen delivery.
Which way is the curve shifted in a newborn?
Left shift (fetal hemoglobin).
What does a blood gas analyser measure and calculate?
Measures:
pH
pCO₂
pO₂
Calculates:
HCO₃⁻
Base excess
O₂ saturation
45. Other analytes incorporated?
Na⁺
K⁺
Ca²⁺
Glucose
Lactate
Provides rapid critical-care testing.
Which electrode is the Clarke electrode?
pO₂ electrode.
Primary source of error for pO₂?
Air bubbles.
Source of pre-analytical error?
Delayed analysis, air contamination, improper mixing, clots.
Reference electrode of pH electrode?
Ag/AgCl (silver-silver chloride) reference electrode.
How is pCO₂ electrode similar/different from pH electrode?
Both are potentiometric; pCO₂ electrode indirectly measures CO₂ through a pH change.
Is protein buildup an issue?
Yes, it can affect electrode performance and require maintenance.
How do you calibrate a blood gas analyser?
Using calibration gases, buffers and automated internal calibration.
Are blood gas analysers sensitive to temperature?
Yes.
What is the Nernst equation?
Equation relating electrode potential to ion concentration/activity.
Should blood gas results be corrected for temperature?
Generally reported at 37°C, though temperature-corrected values may be available.
What is base excess?
Amount of acid or base needed to return blood to normal pH.
How do you collect a proper blood gas specimen?
Heparinized syringe
Remove air bubbles
Mix thoroughly
Analyse promptly
Keep on ice if delayed >30 min
Sources of blood gas collection error?
Air bubbles
Clots
Hemolysis
Delayed testing
Inadequate mixing
Excess liquid heparin
Incorrect patient/sample identification
Limitations of QC for blood gases?
QC material is aqueous and does not perfectly mimic whole blood.
Benefit of proficiency testing?
Verifies accuracy and inter-laboratory performance.
Large bubble in syringe. Acceptable?
No. Remove bubble immediately if possible. Air contamination can:
Increase pO₂
Decrease pCO₂
Alter pH
Sample found 1 hour later. Acceptable?
Generally reject or recollect. Cellular metabolism causes:
↓ pO₂
↑ pCO₂
↓ pH
How often should QC be performed?
Follow manufacturer and laboratory policy; typically multiple levels performed daily and after maintenance.
Repeat critical result: verify first or second run?
Accept/report the first run if technically valid because delay allows ongoing sample metabolism and can worsen accuracy.