ECE BME QUIZ 3

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/278

encourage image

There's no tags or description

Looks like no tags are added yet.

279 Terms

1
New cards

[10a] Name the 4 main non-blood diagnostic samples listed

Urine, bone marrow, tissue samples (biopsy), plus emerging ones (saliva, nasopharyngeal swab, breath, tears, stool)

2
New cards

[10a] Urine is used to diagnose

Prostate cancer, urinary tract infection (UTI), drug monitoring

3
New cards

[10a] Bone marrow is

Semi-solid tissue; primary site of new blood cell production. Used for childhood cancers, myeloid and lymphoid leukemia

4
New cards

[10a] Tissue samples are collected by

Biopsy; used for cancer diagnostics

5
New cards

[10a] Saliva is used for

Oral health and respiratory infections

6
New cards

[10a] Nasopharyngeal swab is used for

Respiratory infections (COVID-19, influenza), whooping cough, diphtheria

7
New cards

[10a] Breath samples are used for

Cancer biomarkers, e.g. lung cancer

8
New cards

[10a] Tears are used for

Eye health diagnostics

9
New cards

[10a] Stool is used for

Microbiome and cancer diagnostics

10
New cards

[10a] Whole blood is collected mainly by

Venipuncture or finger prick

11
New cards

[10a] List whole blood biomarkers

Blood cells, circulating proteins, cytokines, miRNA, cfRNA, cfDNA, pathogens, exosomes, circulating tumor cells (CTCs), antibodies, other molecules (lactate, glucose, drugs)

12
New cards

[10a] cfDNA stands for

Circulating free DNA

13
New cards

[10a] cfRNA stands for

Circulating free RNA

14
New cards

[10a] CTC stands for

Circulating tumor cell

15
New cards

[10b] Why do we collect blood?

Diagnostics, therapy monitoring, blood transfusion

16
New cards

[10b] Venipuncture is

Process of obtaining intravenous access to collect venous blood

17
New cards

[10b] Vacutainer tubes are coated with

Additives (anticoagulants) to prevent clotting, e.g. EDTA and heparin

18
New cards

[10b] Anticoagulant examples

EDTA and heparin

19
New cards

[10b] Purpose of anticoagulants in collection tubes

Prevent blood clotting

20
New cards

[10b] Rotisserie is used to

Mix blood samples after collection in a vacutainer tube

21
New cards

[10b] New venipuncture technology

Automated robotic arm with multiple degrees of freedom (DOF) to control the needle, plus near-infrared (NIR) imaging to find veins

22
New cards

[10b] NIR imaging in automated venipuncture is used to

Find/locate veins

23
New cards

[10b] Finger prick is

Pricking a finger with a lancet to get a small quantity of capillary blood (also called finger stick)

24
New cards

[10b] Best fingers for finger prick

3rd and 4th fingers

25
New cards

[10b] Where NOT to prick the finger

Do not use the tip or center; avoid the side of the finger

26
New cards

[10b] Avoid pricking a finger that is

Cold or blue, swollen, scarred, or covered with a rash

27
New cards

[10b] How to warm a cold finger before pricking

Wrap a warm cloth or rub the finger with your hand

28
New cards

[10b] Finger prick site is cleaned with

Alcohol swab; let it air dry completely before pricking

29
New cards

[10b] After the finger prick, what do you do with the first drop?

Wipe it off with dry clean cotton wool

30
New cards

[10b] Finger prick requires what kind of lancet

Sterile lancet with full skin penetration for adequate blood flow

31
New cards

[10b] Neonatal heel prick volume

About 300-500 uL using multiple blood drops

32
New cards

[10b] Main way to collect blood from neonates

Heel prick (others: venous or arterial needle sticks)

33
New cards

[10b] Finger prick vs venous: parameter with the highest correlation listed (PCT)

PCT (plateletcrit) r = 0.999; MCV also very high (0.996); total WBC 0.991

34
New cards

[10b] Finger prick vs venous: basophil percentage correlation

Essentially none (r = 0.002)

35
New cards

[10b] Finger prick vs venous CD4 study

110 HIV-infected Malawian adults; bias 6.6 cells/uL (limits -50.7 to 63.7) for absolute counts; 0.71% bias for %CD4/lymphocyte

36
New cards

[10b] Whole blood composition: plasma fraction

55% of whole blood

37
New cards

[10b] Whole blood: platelets per uL and size

3 x 10^5 per uL; 1-2 um

38
New cards

[10b] Whole blood: RBC per uL and size (per slide)

5 x 10^6 per uL; 4-5 um

39
New cards

[10b] Whole blood: WBC per uL and size

7 x 10^3 per uL; 7-14 um

40
New cards

[10b] Whole blood: granulocytes + monocytes per uL and size

4 x 10^3 per uL; 9-14 um

41
New cards

[10b] Whole blood: lymphocytes per uL and size

3 x 10^3 per uL; 7-8 um

42
New cards

[10b] Most abundant cell in blood

RBCs (about 5 x 10^6 per uL)

43
New cards

[10b] Where are proteins, cytokines, antibodies, cfDNA, cfRNA, microRNA found?

Blood plasma

44
New cards

[10b] Two main divisions of whole blood biomarkers

Cell biomarkers and plasma biomarkers

45
New cards

[10b] Cell biomarkers include

Cell counts, surface protein expression, morphological changes, mechanical properties, cellular contents (e.g. pro-viral load), circulating tumor cells

46
New cards

[10b] Plasma biomarkers include

Proteins, cytokines, antibodies, cfDNA, cfRNA, microRNAs and others

47
New cards

[10b] If you want to count RBCs, you need

Blood dilution (RBCs are highly abundant)

48
New cards

[10b] If you want WBCs and their subtypes, you need

RBC lysis (to remove highly abundant RBCs)

49
New cards

[10b] If you want plasma biomarkers, you need

Plasma separation

50
New cards

[10b] To quantify both cell and plasma biomarkers

Integrate plasma separation + RBC lysis modules (and possibly blood dilution)

51
New cards

[10b] Hemolysis

Rupturing (lysis) of RBCs and release of their contents into surrounding fluid

52
New cards

[10b] Osmosis

Spontaneous net movement of solvent through a selectively permeable membrane into a region of HIGHER solute concentration

53
New cards

[10b] Isotonic solution effect on RBC

Cells keep normal size/shape (no net osmosis)

54
New cards

[10b] Hypertonic solution effect on RBC

Cells lose water and shrink (crenate)

55
New cards

[10b] Hypotonic solution effect on RBC

Cells take on water, swell and burst (lyse)

56
New cards

[10b] RBC lysis by osmotic swelling works by

Making the solution hypotonic: lower solute concentration outside the cell creates inward osmotic pressure, cell swells and bursts

57
New cards

[10b] ACK lysing buffer: blood to buffer ratio

1 mL EDTA whole blood into 10-20 mL ACK buffer at room temp

58
New cards

[10b] ACK lysing incubation time

3-5 minutes at room temperature

59
New cards

[10b] ACK protocol centrifugation

300 x g for 5 minutes (room temp first, then 2-8 C after PBS wash)

60
New cards

[10b] ACK protocol: leave how much supernatant

About 50 uL to avoid disturbing the pellet

61
New cards

[10b] ACK protocol: wash solution

5 mL cold phosphate buffered saline (PBS)

62
New cards

[10b] ACK protocol: blood collection tube type

EDTA-treated tubes (venipuncture)

63
New cards

[10b] Microfluidic RBC lysis: lysis solution

0.12% (v/v) formic acid + 0.05% (w/v) saponin in DI water

64
New cards

[10b] Microfluidic RBC lysis: quenching solution

0.6% (w/v) sodium carbonate + 3% (w/v) sodium chloride in DI water

65
New cards

[10b] Why use a quenching solution?

Stops lysis so WBCs are not damaged/permeabilized

66
New cards

[10b] Microfluidic lysis time scale

Seconds (RBC lysis seen over about 0.5 to 5.5 s) vs minutes for traditional ACK

67
New cards

[10b] Microfluidic lysis: 3 s vs 8 s

At 3 s cells are not permeabilized; at 8 s lymphocytes start to permeabilize and shift left on the plot

68
New cards

[10b] Why optimize lysis time?

To prevent WBCs from becoming permeabilized

69
New cards

[10b] Impedance at low frequency (500 kHz) measures

Cell size

70
New cards

[10b] Impedance at high frequency (1.7 MHz) measures

Cell morphology, granularity and permeabilization

71
New cards

[10b] Opacity vs output voltage plot axes

Opacity (y) vs output voltage at low frequency (x)

72
New cards

[10b] Traditional plasma separation

Centrifugation of whole blood

73
New cards

[10b] After centrifugation: layers

Plasma (about 55%) on top, buffy coat (leukocytes + platelets, under 1%) in the middle, erythrocytes (about 45%) at the bottom

74
New cards

[10b] Buffy coat contains

Leukocytes and platelets (<1% of whole blood)

75
New cards

[10b] Plasma composition

About 91% water, about 7% proteins, plus traces of bacteria, viruses, metabolites, circulating nucleic acids

76
New cards

[10b] Parameters to consider in microfluidic plasma separation

Initial blood dilution, rate of plasma collection, overall assay time, fraction of plasma separated, possible hemolysis

77
New cards

[10b] Microfluidic plasma separation principle

Cells migrate toward channel walls, leaving a low-cell region near the axial center where plasma is collected

78
New cards

[10b] Microfluidic plasma separation device geometry

Serpentine channels; plasma collected at the middle outlet branch, cells at the side branches

79
New cards

[10b] Microfluidic plasma separation result

With 25x dilution in 1x PBS, over 90% plasma purity

80
New cards

[14a] Hemocytometer is

Thick glass slide with a rectangular indentation (counting chamber) with a known gridded area and known depth, used to count cells

81
New cards

[14a] Hemocytometer uses

Counting cells, live/dead analysis, efficacy of cell culture

82
New cards

[14a] Hemocytometer chamber depth

0.1 mm

83
New cards

[14a] Hemocytometer: 1 x 1 mm square volume

1 mm^2 area, 100 nL at 0.1 mm depth

84
New cards

[14a] Hemocytometer: 0.25 x 0.25 mm square volume

0.0625 mm^2, 6.25 nL

85
New cards

[14a] Hemocytometer: 0.25 x 0.20 mm square volume

0.05 mm^2, 5 nL

86
New cards

[14a] Hemocytometer: 0.20 x 0.20 mm square volume

0.04 mm^2, 4 nL

87
New cards

[14a] Hemocytometer: 0.05 x 0.05 mm square volume

0.0025 mm^2, 0.25 nL

88
New cards

[14a] How many 1 x 1 mm squares in the gridded area?

Nine

89
New cards

[14a] Central 1 mm square is further subdivided into

0.05 x 0.05 mm squares (0.0025 mm^2)

90
New cards

[14a] Hemocytometer counting steps

Pre-process sample (lysis, dilution) > pipette onto hemocytometer > image under microscope > count cells in specific regions > calculate concentration (cells per unit volume)

91
New cards

[14a] Concentration from hemocytometer count

cells counted divided by volume of counted region (count / (area x depth)), corrected for dilution

92
New cards

[14a] Cell viability formula

Live cells / (live + dead cells)

93
New cards

[14a] Dye used for viability on a hemocytometer

Trypan blue

94
New cards

[14a] Viable cells with trypan blue

Intact membranes, do NOT take up dye, appear bright/clear

95
New cards

[14a] Dead cells with trypan blue

Damaged membranes take up dye, appear blue

96
New cards

[14b] Blood cell biomarkers (flow cytometry)

Size, numbers and types, surface proteins (CD4, CD8, CD64, CD11b), expression of surface proteins

97
New cards

[14b] Flow cytometry is the ___ in health-care settings

Current standard; optical based with fluorescence detection

98
New cards

[14b] Flow cytometry identifies cell types by

Tagging with conjugated fluorescent antibodies

99
New cards

[14b] Flow cytometry drawbacks

Expensive ($50k to over $125k), about $10k/year maintenance contracts, trained technicians necessary

100
New cards

[14b] Four parts of a flow cytometer

Fluidics system, lasers, optics, detectors, plus electronics and computer system