GCAMS Block 2

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/53

encourage image

There's no tags or description

Looks like no tags are added yet.

54 Terms

1
New cards

Definition of A Transmissom Line

a device that guides electrical energy from one point to another

2
New cards

Purpose of a Transmission Line

to connect a signal source to a load

3
New cards

Source

generator or sending end

4
New cards

Load

output or receiving end

5
New cards

Impedance

comparable to resistance

6
New cards

Parallel Wire

also called two-wire or ribbon line. spaced from 1/4 of an inch to several feet apart

7
New cards

Twisted Pair

two insulated wires twisted together. Flexible. Not used for higher frequencies.

8
New cards

Shielded Pair

parallel conductors surrounded by a solid dielectric

9
New cards

Rigid Coax

CENTRAL INNER CONDUCTOR is surrounded by solid dielectric. The dielectric is mounted inside a rigid non-flexible outer conductor.

10
New cards

Flexible Coax

shielding has a rubber composition coating

11
New cards

Wave Guide

Rigid, hollow metal or dielectric tube. Allow the transmission of high frequencies with least amount of loss.

12
New cards

Transmission Line Impedance

effect of impedance on RF energy transmission is comparable to resistance

13
New cards

Characteristic Impedance

ratio of E to I, ratio will. ratio will be equal at every point along the line

14
New cards

Effect of Characteristic Impedance

maximum power and minimal losses

15
New cards

Incident

source to load

16
New cards

Reflected

load to source

17
New cards

Standing Wave

results from the algebraic addition of the incident wave to the reflected wave

18
New cards

Resonant

standing waves are present; not terminated in its Zo, also called a TUNED line

19
New cards

Non-resonant

no standing waves present; is terminated in Zo, also called an UNTUNED line, theoretically a perfect line

20
New cards

Effect of Standing Waves on energy transmission

maximum power will NOT be transmitted

21
New cards

Standing Wave Ratio

Ideal ratio is 1:1

22
New cards

Forms of SWR

VSWR, PSWR, ISWR

23
New cards

Power Loss

energy dissipated as heat

24
New cards

Induction loss

Current induced in nearby metal object, power dissipated

25
New cards

Radiation Loss

Magnetic lines of force projected into space resulting in power loss

26
New cards

Transmission Line Terminated in Zo

no reflections, no standing waves, and 100% power

27
New cards

Transmission Line Not Terminated in Zo

has reflections, standing waves, maximum power will NOT be transmitted

28
New cards

Termination

impedance matching, RF loading

29
New cards

Attenuator

Reduces power level of transmitted signal at a specified frequency

30
New cards

Mismatch/Offset Termination

Insert a known amount of SWR into a transmission line

31
New cards

Directional Coupler

sample incident and reflected microwave, minimal disturbance

32
New cards

Isolator

allows max forward conduction while eliminating reverse conduction

33
New cards

RF Filter

allows certain frequencies to pass while rejecting other frequencies

34
New cards

Impedance Matching

feed through termination

35
New cards

RF load

power is dissipated as heat, dummy load

36
New cards

Mismatch/Offset Termination

adds a known amount of SWR into transmission line; calibrated with a known amount of SWR

37
New cards

Attentuators

reduce the power of the transmitted signal

38
New cards

Attenuation Of RF Signals

reduction of the signal amplitude to a measurable level

39
New cards

Termination

constructed of resistive material at a predetermined resistance sealed

40
New cards

Fixed Attenuator

Constructed of fixed graphitized sand

41
New cards

Variable Attenuator

a resistive rod or vane is placed at the center of an electric field

42
New cards

Isolator

a non-reciprocal device employing ferries biased

43
New cards

Attenuators and Terminations

clearly marked to show the level of attenuation or resistance; specified frequency range

44
New cards

Correction Graph

provided to show actual attenuation factor at specified frequencies

45
New cards

Pin Depth

measured with a dial indicator

46
New cards

Signal Source

Standard signal generator

47
New cards

Slotted Line

consists of a probe that samples the electric field

48
New cards

SWR Meter

High gain tuned audio amp

49
New cards

Impedance Bridge

consists of three connectors; RF input, reflected RF output, and Device under Test (D.U.T.)

50
New cards

Scalar Analyzer

an automated system

51
New cards

Using a Slotted Line and SWR meter

signal source injects modulated signal

52
New cards

Cleanliness

contaminated connectors will cause unwanted VSWR

53
New cards

Attenuator Cables

use as few cables as possible, use short cable, higher frequencies require shielded cable

54
New cards

Attenuator Adjustments

none are possible