1
New cards

Histogram

A smoothed bar graph plotting the frequency of pixel values or values of interest from raw image data, which functions alongside the lookup table to control image brightness and contrast.

2
New cards

Lookup Table (LUT)

An algorithmic mathematical formula of binary numbers (ones and zeros) that converts rescaled image pixel values into new numbers to refine image brightness and the scale of contrast.

3
New cards

Raw Data

The unprocessed data collected directly by the image receptor from the patient, encompassing all values located both inside and outside the collimation borders.

4
New cards

Values of Interest (VOI)

The specific numerical pixel values located inside the collimated exposure field that are extracted and utilized to generate the final image.

5
New cards

Rescaled Histogram

A blended histogram created when the computer algorithm merges the patient's actual raw values of interest with a preprogrammed anatomical model.

6
New cards

Region of Interest (ROI)

The collimated anatomical area identified by the computer where image data is collected and processed while excluding outside background data.

7
New cards

Spatial Resolution

The sharpness or ability of an imaging system to record small anatomical structures in fine detail, governed by matrix size, pixel size, field of view, and detector element size.

8
New cards

Matrix

A checkerboard-like arrangement of rows and columns composed of individual pixels used to construct a digital image.

9
New cards

Pixel

A picture element, typically square, that is assigned a specific numeric value corresponding to a distinct shade of gray.

10
New cards

Voxel

A three-dimensional volume element that represents the thickness of an anatomical slice, used predominantly in computed tomography (CT\text{CT}).

11
New cards

Pixel Pitch

The physical distance measured from the center of one pixel to the center of an adjacent pixel, where a shorter distance corresponds to higher spatial resolution.

12
New cards

Field of View (FOV)

The usable anatomical viewing area displayed on the monitor after cropping or collimating away unneeded outer margins.

13
New cards

Detector Element (DEL)

A microscopic hardware unit within a digital radiography detector containing a thin-film transistor (TFT\text{TFT}), capacitor, and readout electronics that corresponds to an image pixel.

14
New cards

Modulation Transfer Function (MTF)

A measurement evaluating how accurately all parts of an imaging system work together to preserve anatomical detail and sharpness, rated on a scale from 00 to 1.01.0 (or 0%0\% to 100%100\%).

15
New cards

Spatial Frequency

A metric representing spatial resolution expressed in line pairs per millimeter (lp/mm\text{lp/mm}) that is evaluated when assessing Modulation Transfer Function (MTF\text{MTF}).

16
New cards

Quantization

The digital processing step in which the computer assigns a specific numerical value corresponding to a shade of gray to a pixel based on the captured X-ray signal strength.

17
New cards

Pixel Bit Depth

The total pool or range of numbers and shades of gray available to be assigned to pixels during quantization, determined by the binary numbering system of the system's CPU.

18
New cards

Grayscale

The comprehensive range of shades of gray established by an imaging system's bit depth from which pixels are displayed.

19
New cards

Contrast Resolution

The ability of a detector element to distinguish between anatomical structures that exhibit small changes in signal intensity from the exit beam, accurately recording subtle differences in subject contrast.

20
New cards

Dynamic Range

The range of X-ray exposure intensities that a detector element can accurately capture and convert into usable image data, spanning from minimally exposed to highly exposed regions.

21
New cards

Exposure Latitude

The margin of error or range of exposure factors at the radiographer's disposal that will produce a diagnostic-quality image at an appropriate patient dose.

22
New cards

Detective Quantum Efficiency (DQE)

A measure evaluating how effectively an imaging system converts the exit radiation beam into a diagnostic image while preserving an optimal signal-to-noise ratio.

23
New cards

Signal-to-Noise Ratio (SNR)

The proportion of useful diagnostic image information compared to the combined background quantum noise and electronic interference present in the captured signal.

24
New cards

Window Level

A post-processing control that adjusts image brightness by shifting the displayed range of numerical pixel values up or down.

25
New cards

Window Width

A post-processing control that adjusts image contrast by expanding or narrowing the total span of pixel values mapped across the displayed grayscale.

26
New cards

Edge Enhancement

A post-processing algorithm that artificially increases contrast along structural boundaries to sharpen demarcation, though excessive use can introduce noise and halo artifacts.

27
New cards

Smoothing

A post-processing filtering operation applied to suppress low-level digital noise, which concurrently reduces the overall scale of image contrast.

28
New cards

Equalization

An algorithm—also known as dynamic range compression—that alters overall contrast and compresses file size by subtracting the extreme light and dark areas of an image.

29
New cards

Flat-fielding

An automated preprocessing calibration technique applied to remove fixed-pattern noise and irregularities across the detector field, such as the anode heel effect.

30
New cards

Dead Pixel Correction

A preprocessing operation that assigns interpolated numerical values to defective or unresponsive detector elements by averaging data from neighboring functioning pixels.

31
New cards

Saturation

A gross overexposure artifact resulting from receiving 88 to 1010 times the normal radiation exposure, producing completely flat, black anatomical areas incapable of post-processing recovery.

32
New cards

Shuttering

A post-processing manipulation technique also known as masking or cropping, where excess bright white light around collimated borders is replaced with a black background to eliminate veil glare.