Sinus rhythm
The SA node sends out electrical impulses in a coordinated manner
P wave
Represents atrial contraction
Q wave
Represents the electrical impulse leaving the Bundle of His and the beginning of the interventricular septum depolarizing from left to right
R wave
Represents the electrical impulse passing through the ventricles
S wave
Represents the electrical impulse leaving the ventricles
T wave
Represents the ventricles in the recovery phase in order to being the next cardiac cycle
PR interval
0.12 and 0.22 sec
Regularly irregular
Rhythm is irregular on a regular basis
Irregularly irregular
Abnormalities in the atria cause no consistent patterns between R-R peaks, no similarities between PR intervals or QRS complexes, and ventricular rate varies
Sinus tachycardia
Regularly irregular sinus rhythm
Notify if HR is in 140s
Sinus bradycardia
Regularly irregularly sinus rhythm
Notify if HR is in 40s
Supraventricular tachycardia (SVT)
Electrical impulse originates at or above the AV node, causing a regularly irregular HR between 150 and 200 BPM
Why is the AV node the primary pacemaker in SVT?
The SA node is dysfunctioning, preventing the normal resting delay that allows the chambers to fill with blood
SVT P waves
Absent or merged with T waves due to the rapid HR
SVT QRS complex
Narrow due to the absence of a normal resting delay that allows the chambers to fill with blood
A-fib
Rapid and chaotic quivering of the atria, causing an irregular rhythm that is out of sync with the ventricles and blood pooling in the atria
A-fib P waves
Indistinguishable, instead there is a small wavy line before each QRS complex
A-fib QRS complex
Usually normal, but can be wide if there are conduction delays
Atrial flutter
Rapid but regular atrial beating, causing a sawtooth pattern (F waves)
F waves
Each QRS complex has more than one P waves, causing a sawtooth pattern formed by the atria beating too rapidly but regularly
Junctional rhythm
The AV node generates the electrical impulses because the SA node is slowed down, fails, or is blocked, causing the HR to be too slow or too fast
Junctional rhythm P waves
Inverted or hidden within the QRS complex
Multifocal PVCs
Multiple areas within the ventricles become irritated by the electrical impulses, which does not follow the normal pathway from either node, causing out of sync contractions
Multifocal PVCs P waves
Absent before the QRS complex or are retrograde (appear after the QRS), distorting the ST segment
Multifocal PVCs QRS complexes
Wide and have an abnormal appearance
Multifocal PVCs T waves
Point in the opposite direction from the QRS complex
PVCs
Absent P waves due to the atria and ventricles beating out of sync from each other
V-fib
An erratic pattern of electrical activity in which electrical impulses originate from many different focus points in the ventricles or Purkinje fibers
V-fib EKG morphology
No P waves, QRS complexes, PR intervals, or QT segments
Monomorphic ventricular tachycardia (V-tach)
The ventricles beat at a dangerously rapid pace of 130 to 250 BPM and all of the waves have the same consistent shape
V-tach morphology
Wide QRS complexes with distinct tall “left rabbit ear” shape
Idioventricular rhythm (IVR)
The ventricles take over as the primary pacemaker because the SA node fails or is blocked, causing the ventricles to beat at a dangerously low rate between 20 and 40 BPM
IVR P waves
Absent due to the SA node not functioning properly
IVR QRS complexes
Wide (similar to V-tach) due to the electrical impulses spreading abnormally through the ventricles, instead of the usual pathways
1st degree AV block
Mild heart condition in which electrical signals slowly pass from the atria to the ventricles
1st degree AV block PR intervals
Prolonged due to the electrical signal moving slowly
2nd degree AV block Mobitz type I (Wenckerbach)
Electrical signals from the atria are delayed longer and longer until a beat is dropped
2nd degree AV block Mobitz type I PR intervals
Become progressively longer until a QRS complex is missed, then the cycle repeats
2nd degree AV block Mobitz type II (Hay Block)
Electrical signals from the atria are intermittently blocked in the His-Purkinje system below the AV node, causing dropped QRS complexes
2nd degree AV block Mobitz type II QRS complexes
Appearance varies and are dropped suddenly without prior PR interval changes
Complete heart block
Electrical signals from the atria are completely blocked from reaching the ventricles, so each pacemaker works independently and causes slow ventricular contractions
Complete heart block P waves
May appear before or after a QRS complex and look normal
May be hidden within QRS complex
May be mixed with T waves
Complete heart block PR intervals
Inconsistent due to the atria and ventricles beating out of sync