1/54
Purpose of masking
for obtaining ear specific information
Make sure response are from TE and not NTE
When do we usually mask?
usually for unilateral or asymmetric loss or bone conduction testing when there is an air bone gap
air bone gap for masking
15 dB or more
What is cross over
sound from TE crosses over to NTE and is heard
earphone vibrates and acts like bone oscillator
When does cross over typically occur
BC more than AC
intramural attenuation
the amount of energy that is reduced as sound travels from TE to NTE
different value for headphones, inserts, and BC oscillator
Intramural attenuation equation
IA= dB HL(TE) - dB HL(BTE)
not thresholds
actual intensity of sound
Result of IA when NTE is not good and TE good
threshold of TE not accurate
Rule of thumb for AC
IA for headphones 40 dB HL
IA for inserts 1k, 500, 250 use 85 dB HL
2k, 4k, and 8k use 50 dB HL
what do we use in clinic for inserts
60 dB HL
what do we use in clinic for headphones
40 dB HL
when to mask for AC
difference between AC threshold of test ear at that frequency and BC threshold of NTE at that frequency is greater than IA
Equation for when to mask for AC
AC(TE) - BC(NTE) greater than or equal to IA
What if you don’t know BC thresholds yet?
estimate BC for NTE
at most BC will be 10 dB better than air of NTE
describe masking noise
pure tone stimuli
narrow band noise
use enough to make threshold on NTE less than IA
Masking for BC
IA for bone oscillator
when do you need to mask for bone?
whenever unmasked bone suggests air bone gap of 15 dB HL or more in TE
Where does the sound go during BC?
tone through bone oscillator on mastoid of test ear
masking noise through insert or headphone on NTE
Minimum masking level
minimum amount of energy of masking noise needed to isolate the response of the TE
Minimum masking level equation
Presentation level (TE)- IA + airborne gap (NTE)
Initial masking level
1st amount of masking presented to NTE
sometimes initial masking level is not enough
Initial masking level for AC
AC(NTE)+ 10 dB
Initial masking level for BC
AC (NTE) + occlusion effect + 10 dB
Occlusion effect for headphones for BC
30 dB @250 Hz
20 dB @500 Hz
10 dB @1k Hz
Occlusion effect for inserts for BC
10 dB @250 Hz
10 dB @500 Hz
0 dB @1K Hz
Maximum masking level
maximum amount of masking that will not change the threshold of the test ear
masking noise you can present without over masking
equation for maximum masking level
BC(TE) + IA- 5
Plateau method
common in clinic
looks at relationship between masking level and threshold in TE
establish threshold w/o masking
introduce masking
goal of plateau method
find level where threshold doesn’t change with incremental increase in masking level
15-20 dB increase in masking level
shadow curve
when it appears a patient has better hearing than they actually have
result of crossover
may result in incorrect diagnosis and inappropriate HA fitting
Red flags of shadow curves
shape of poor ear thresholds are the same as good ear thresholds
thresholds of each ear are separated by IA
IA for speech
40 or 50 dB for headpohnes
60 dB for inserts
When do we mask for speech (suprathreshold speech testing)
presentation level (TE) - speech threshold (NTE) greater than or equal to IA
When do we mask for speech (threshold speech testing)?
speech threshold (TE) - speech threshold (NTE) greater than or equal to IA
does the plateau method work for speech testing?
no
how much masking do we use for speech testing?
between minimum and maximum masking level
Minimum masking level for speech
presentation level (TE)- IA + largest air bone gap (NTE)
maximum masking level for speech
best BC (TE) + IA - 5 dB
overmasking
It is possible to present too much masking noise and shift the threshold of the TE
this happens when masking noise from NTE crosses over to the TE
Results of overmasking
masking dilemma
Masking dilemma
amount of masking needed to get a true threshold in the TE will be overmasking
masking efficiency
determined by the amount of masking obtained relative to the total amount of noise
related to concept of critical band
2 components of critical band
only frequencies within a restricted band with the test tone as the characteristic frequency will have a masking effect
threshold is related to the amount of energy in the critical band
broadband noise
acoustic spectrum is determined by frequency response of transducer
most transducers have flat frequency response through 6k Hz
white noise can be shaped like speech
Parts of narrow band noise
center frequency
bandwidth
rejection rate
center frequency
most sound eneryg
bandwidth
span of frequency whose intensities are no more than 3 dB below the peak component of the band
rejection rate
decrease in intensity over a range of one octave on each side of the band
other aspects of narrow band noise
most efficient noise
bandwidth slightly wider than the critical band
easily distinguished from pure tones
for pure tones use?
narrow band noise (white noise second choice)
for speech use?
weighted noise
weighted noise
white noise that has beens shaped to match the long term spectrum of speech
instruction for masking
tell patients they will hear noise and respond to test signal
should you report your masking levels on an audiogram?
yes
find a spot if there isn’t a dedicated one
how do you mark a masking dilemma on an audiogram
report unmasked levels with a *
leave a note stating *masknig dilemma in comments