1/25
Looks like no tags are added yet.
Positioning the ENG 1 hydraulic pump switch to OFF isolates fluid flow from the system components and the pump ____ to rotate. a) ceases b) continues
b) continues
If a leak develops in the A system hydraulic electric motor-driven pump or its related lines: a) a standpipe in the reservoir prevents a total system fluid loss b) the quantity in the reservoir steadily decreases to zero and all system pressure is lost c) The system quantity will steadily decrease to 15%
b) the quantity in the reservoir steadily decreases to zero and all system pressure is lost
The purpose of the PTU is to supply the additional volume of hydraulic fluid needed to operate the autoslats or the leading edge flaps and slats at the normal rate when: a) the standby system volume is lost b) system A engine-driven pump volume is lost c) system B engine-driven pump volume is lost
c) system B engine-driven pump volume is lost
The purpose of the landing gear transfer unit is to raise the landing gear at the normal rate when: a) system A engine-driven pump volume is lost due to a #1 engine failure b) the standby system volume is lost c) system B engine-driven pump volume is lost due to a #2 engine failure
a) system A engine-driven pump volume is lost due to a #1 engine failure
If a leak develops in either pump, line, or component of System B: a) the quantity in the reservoir steadily decreases to approximately zero, system B pressure and the standby system pressure is lost b) the quantity in the reservoir steadily decreases to approximately zero and system B pressure is lost, however the power transfer unit is still operational c) The system quantity will steadily decrease to 15%
b) the quantity in the reservoir steadily decreases to approximately zero and system B pressure is lost, however the power transfer unit is still operational
The standby system _______ and uses a single electric motor-driven pump. a) can only be activated by placing the ALTERNATE FLAPS Master Switch to ARM b) can be activated manually or automatically c) can only be activated by positioning either FLIGHT CONTROL switch to STBY RUD
b) can be activated manually or automatically
Pulling an engine fire warning switch shuts off the hydraulic fluid flow to the related engine-driven pump and: a) engages the standby hydraulic system b) deactivates the ENG # hydraulic LOW PRESSURE light c) activates the ENG # hydraulic LOW PRESSURE light
b) deactivates the ENG # hydraulic LOW PRESSURE light
The landing gear transfer unit operates when airborne, the No. 1 engine RPM drops below a limit value, ______________. a) the landing gear is positioned up, and either main landing gear is not up and locked b) the landing gear is positioned up, and both main landing gear are not up and locked and a main landing gear is not up and locked
a) the landing gear is positioned up, and either main landing gear is not up and locked
Automatic operation of the standby hydraulic pump is initiated when loss of hydraulic system A or B, and: a) flaps extended; and airborne, or wheel speed greater than 60 knots b) flaps retracted and airborne c) all answers are correct
a) flaps extended; and airborne, or wheel speed greater than 60 knots
If a leak develops in the A system hydraulic engine-driven pump or its related lines: a) the system quantity will steadily decrease to 15% b) the quantity in the reservoir steadily decreases to zero and all system pressure is lost c) a standpipe in the reservoir prevents a total system fluid loss
c) a standpipe in the reservoir prevents a total system fluid loss
_______ hydraulic system is capable of providing full power control to the ailerons. a) Only the A b) Only the B c) Either
c) Either
The aircraft has ______ hydraulic systems. a) two b) three c) four
b) three
______ can power all flight controls with no decrease in aircraft controllability. a) The RAT b) The standby hydraulic system c) Either A or B hydraulic system
c) Either A or B hydraulic system
Normal operating pressure for each hydraulic system is ______ psi. a) 2,000 b) 3,000 c) 3,500
b) 3,000
The minimum fuel for ground operation of electric hydraulic pumps is _____ in the related main tank. a) 1000 lbs. b) 1675 lbs. c) 2000 lbs.
b) 1675 lbs.
A leak in hydraulic system B ______ the operation of the standby hydraulic system. a) inhibits b) does not affect
b) does not affect
A leak in hydraulic system A ______ the operation of the standby hydraulic system. a) inhibits b) does not affect
b) does not affect
The standby hydraulic system powers the thrust reversers, rudder, and: a) leading edge flaps and slats (extend only) and the standby yaw damper b) leading edge flaps and slats (extend and retract) and the standby yaw damper c) leading edge flaps and slats (extend only), autobrakes and the standby yaw damper
a) leading edge flaps and slats (extend only) and the standby yaw damper
Positioning the ALTERNATE FLAPS master switch to ARM:
b) activates the standby electric motor-driven pump
An amber illuminated Electric Hydraulic Pump OVERHEAT light indicates: a) the hydraulic fluid used to cool and lubricate the corresponding electric motor driven pump has overheated b) the pump itself has overheated c) all answers are correct
c) all answers are correct
Positioning the ELECTRIC HYDRAULIC PUMP Switch to ON: a) allows for transfer of hydraulic system fluid between system A and the standby system b) controls the related electric motor-driven pump c) allows for transfer of hydraulic system fluid between system B and A with the parking brake set
b) controls the related electric motor-driven pump
The HYDRAULIC System QUANTITY is shown on the DU, and indicates digital ______ of hydraulic quantity. a) gallons b) quarts c) percentage
c) percentage
An illuminated amber Flight Control LOW PRESSURE light indicates low hydraulic system A or B pressure to: a) ailerons and elevator b) rudder c) all answers are correct
c) all answers are correct
An illuminated amber standby hydraulic LOW QUANTITY light indicates low quantity in standby hydraulic reservoir, and is: a) armed only when the standby hydraulic pump operation has been selected or automatic standby pump operation is activated b) deactivated when Engine 2 fire switch has been pulled c) always armed
c) always armed
An illuminated amber standby hydraulic LOW PRESSURE light indicates low output pressure, and is: a) armed only when the standby hydraulic pump operation has been selected or automatic standby pump operation is activated b) deactivated when Engine 2 fire switch has been pulled c) always armed
a) armed only when the standby hydraulic pump operation has been selected or automatic standby pump operation is activated
On the PFD/ND, hydraulic system quantity is displayed: a) on the Upper Display Unit b) at all times with the secondary engine indications c) by pushing the MFD System (SYS) switch
c) by pushing the MFD System (SYS) switch