1/114
Looks like no tags are added yet.
most commonly used displays in olden days
tv (most common) or cathode ray tube
why was tv most commonly used before
excellent gray scale rendition at low cost
advantages of crt monitors (4)
-better viewing angles
-brighter image
-more robust
-cheaper
crt monitor scanning
rapid left to right or raster scan sequence
crt monitor has how many display lines and fps
525 horizontal display lines and 30 fps
crt form of display is called
interlaced
televisions are interlaced to eliminate
flicker
humans can detect flicker in noninterlaced displays with frame rates of _ but not with interlaced display with rates of _
30 hz, 60hz
most us systems use _ display
lcd
in an analog system the electrical voltage/current is generated that is _ to the quantity being observed
proportional
in a digital system the quantity being observed is expressed as a
number
image processor performs what functions (4)
-scan conversion
-preprocessing
-storing image frames
-post processing
receiver is the _ end and scan converter is the _ end of the system
front, back
receiver is where all processing takes place [before or after] signal is sent to back end for conversion and storage
before
scan converter two roles
stores and performs scan conversion for image to be viewed on video monitors (raster scanning)
grayscale imaging was initially made possible with the use of _
scan converters
storage of image info in the scan converter is called
writing
scan converter translates the info from _ format into _ format
spoke, video
2 types of scan conversion
analog, digital
first form of scan converter
analog
primary method of storing data for analog scan converters
videocassettes
analog number can have _
unlimited and continuous range of values
analog numbers are _ numbers
“real world”
how are analog scan converters shaped and how do they work
funnel shaped vacuum tube w/ electron gun located w/in its smaller end and electrons that contain image information are shot out of the electron gun
analog scan converters store
electrical charges
the greater the stored charge the greater the _ of the echo
amplitude
limitations of scan converters (9)
-image fade
-image flicker
-instability
-deterioration
-bad detail resolution
-limited frame rate
-difficult and time consuming to copy
-poor video quality if heads of the player get dirty
-rollers wear out
advantage of analog scan converters
good spatial resolution/image detail bc there is a large number of storage elements w/in matrix
digital scan converters use tech to convert images into _, and it is called
numbers, digitizing
digital numbers are associated with/ computer devices and have only _ values
discrete
digital scan converters store an image in computer memory as a series of
0s and 1s
advantages of digital scan converters (5)
-uniformity consistent gray scale quality
-stability
-durability
-speed
-accuracy
digital info is far less susceptible to _
contamination
why is converting info from analog to digital advantageous
digital info is less susceptible to contamination
before the image is displayed on a monitor the digital information must be converted back to _
analog form
5 step process of analog to digital conversion
electrical signals created by transducer during reception are converted from analog to digital by the analog to digital (A-D) converter
digital info is stored in scan converter’s computer memory
image info still in digital form continues to be processed by the ultrasound system’s computer
digital signals are translated back into analog form by a digital to analog (D-A) converter to be able to be displayed on conventional tv (which are analog)
signal in analog form is presented on the video display for interpretation
any processing of reflected signals before storage is called
pre processing
any processing after storage in the digital scan converter is called
post processing
in digital format, values are represented in _ with fixed _ between levels
discrete levels (more specific), steps
two important elements of a digital scan converter
pixel, bit
pixel def
smallest building block of a digital picture
each pixel’s shade of gray is determined by the cluster of _ assigned to it
bits
more shades of gray appear on an image with _ bits per pixel
more
images with many gray shades have superior _ resolution
contrast
pixel density def
number of picture elements per inch
higher pixel density is achieved with _ pixels
smaller
_ resolution improves with higher pixel density and creates a greater detailed image
spatial
how to determine number of shades of gray
2^n ; n = number of bits
most instruments use at least _ bits to represent _ in each pixel location
8, echo amplitude
8 bits provides _ amplitude levels at each pixel location
256
gray scale encodes each pixel value to a
brightness level
the gray scale map is selectable by the
operator
human eye is capable of seeing fewer than _ shades of gray so the minimum number of gray levels on the monitor should be _ and how many bits is that
64, 6 bits
BIT comes from the term
binary digit
BIT is
smallest amount of computer memory, can be either 0 or 1
byte is
a group of eight bits
a word is made up of
two bytes or 16 bits
who controls preprocessing
sonographer
can preprocessing be reversed
no
all receiver functions are [pre, post] processing
pre
preprocessing buttons you can change (6)
-tgc/amplification/gray scale maps
-log compression/dynamic range/compression/reject/power/persistence
-write magnification
-edge enhancement
-image updating
-write zoom
the purpose of tgc and amplification are to compensate for
a loss of energy in the reflected signal caused by attenuation
magnification/zoom magnifies structures by
making region of interest (roi) appear bigger
two different forms of magnification used in us
write, read
write zoom tries to _ maintain by _
maintain pixel density, zooming the image live which produces better spatial resolution
read zoom relies on _ which enlarges the _ in that region
stored images, pixel density
is write or read zoom better
write
write zoom ins aka
acoustic approach
write zoom is done _ data acquisition
during (live)
with write zoom, the number of pixels or scan lines in the roi image is _ than that in the roi portion of the original image
greater
increased number of pixels and line density in write zoom roi improves _ resolution
spatial
how does pixel size change with write zoom
stays the same
you need a _ image to use write zoom
live
who controls post processing
sonographer
can post processing changes be reversed
yes
posit processing we can changes (6)
-any change after freeze frame
-read magnification
-black and white inversion
-contrast variation
-measurements on some machines
-grey scale color maps on some machines
read zoom is aka
non acoustic zoom
the number of pixels or scan lines in read zoom magnified image is _ as the original image
the same
advantage of read magnification
can be used on a frozen image
disadvantage of read zoom
potential for data to appear coarse bc pixels are enlarged (resolution is somewhat compromised, but spatial resolution is still same)
when you apply the freeze button, the scanner
stops acquiring image data and the last values written in memory are frozen
persistence uses _ to create an image that is _
frame averaging, smoother and has less noise
smoothing/spatial averaging is a processing technique used to reduce
noise
disadvantage of smoothing/spatial averaging
lose spatial detail (bc pixels nearby have been averaged into surrounding pixels)
temporal compounding/persistence/temporal averaging is an image processing technique that continues to
display information from older images
edge enhancement is an image processing method that makes pictures look
sharper
edge enhancement works by
increasing image contrast in the area immediately around the edge
edge enhancement creates subtle _ on either side of boundaries to make them appear more defined
bright and dark highlights
bi stable images are composed of what two shades
black and white
contrast determines the range of _ w/in the image
brilliancies
brightness determines the _ of the displayed image
brilliance
what is coded excitation
sophisticated method of improving image quality; creates long sound pulses containing wide ranges of frequency
coded excitation was developed within the context of
bio effects (fda established max peak intensities)
coded pulse is _ but still keeps intensities below the fda limit, giving improved _
strong, penetration
coded excitation happens where
in the pulseer
spatial compounding is a method of
using sonographic info from several different imaging angles to produce a single image
spatial compounding works by acquiring
multiple frames from different viewing angles and then combined (overlapped or compounded) to form a single real time image
the more frames in the compound acquisition sequence the better the
compound image quality
compound imaging reduces
speckle and shadowing artifact
limitations of compound imaging
reduced frame rates/temporal resolution