How do you distinguish flammable and inflammable gases?
From Slide: Flammable and inflammable can be used interchangeably; flammable gases require ignition, while the slide describes inflammable gases as capable of combustion without an ignition source.
In simple words: Both terms describe gases that can burn. The slide distinguishes whether an ignition source is needed.
Slide 3
What are the three medical gas flammability classifications?
From Slide: All medical gases can be classified as flammable, inflammable, or nonflammable.
In Simple words: Medical gases are grouped by whether they can burn or not.
What is a nonflammable gas, and what are four examples?
From Slide: Nonflammable gases do not burn. Examples: nitrogen, oxygen, carbon dioxide, helium.
In simple words: These gases cannot catch fire themselves, including oxygen.
Slide 4
What does it mean that medical gases are dry?
From slide: Medical gases are dry: no water vapor is present. Humidity is sometimes added.
In Simple Words: Medical gas starts without moisture; water vapor may be added for patients.
Slide 6
How does oxygen and air support life?
From Slide: Oxygen and air support metabolic production of energy in carbon-based organisms.
In simple words: Our cells need oxygen from air to make energy.
Slide 6
How is compressed air used to adjust delivered oxygen?
From Slide: Compressed air dilutes 100 percent O2 to provide O2 levels between 22% and 99%; ventilators use air and O2 hoses and a blender.
In simple words: A ventilator mixes air with pure oxygen to set the desired oxygen percentage.
Slide 8
When is compressed air used to power breathing devices?
From Slide: Compressed air is used as a driving pressure for breathing devices when patients do not require supplemental O2.
In simple words: Air can power respiratory equipment without wasting pure oxygen.
Slide 8
How do piped medical air systems maintain 50 psi?
From Slide: Large compressors supply piped air; a pressure-sensitive switch turns the compressor on/off to maintain 50 psi line pressure.
In simple words: Hospital compressors automatically keep the medical air supply near 50 psi.
Slide 9
How do portable compressors prepare air for home use?
From Slide: Small portable compressors are available for home use; condensers and filters remove dust and water.
In simple words: Home compressors provide clean, dry air; they keep dust out of the machine.
Slide 9
Why does oxygen increase fire risk if it is nonflammable?
From Slide: Oxygen is colorless, transparent, odorless, tasteless, and nonflammable; it vigorously accelerates and supports combustion.
In simple words: Oxygen does not burn, but makes other materials burn faster and hotter.
Slide 10
At what temperature does oxygen liquefy at atmospheric pressure?
From Slide: Gaseous O2 can be liquefied at -182.9 C, its boiling point: liquid O2 remains liquid below its boiling point.
Simple words: Cool oxygen below -182.9 C to keep it liquid
Ch 13 Slide 11
How does pressure and temperature affect liquid oxygen?
From Slide: O2 can liquefy under sufficient pressure at -118.6 C; liquid O2 has a pale-blue color.
In simple words: Pressure and cold can turn oxygen into a pale-blue liquid.
Ch 13 Slide 11
What are the four methods of oxygen production?
From Slide: Photosynthesis; electrolysis of water; fractional distillation of air; molecular filtration.
In simple words: Plants make oxygen; electricity splits water; distillation separates liquefied air; filters remove nitrogen.
Ch 13 Slide 12
How does photosynthesis and electrolysis produce oxygen?
From Slide: Photosynthesis is the main source and regulator of atmospheric O2/ electrolysis separates H2O into H and O2 using electricity and is impractical commercially.
In simple words: Plants naturally replenish oxygen. Electric current can split water, but it is not practical for large-scale oxygen production.
ch 13 slide 12
Which method produces bulk O2 and home-concentrator O2?
From Slide: Fractional distillation liquefies, filters, dries, pressurizes, and cools air to mass-produce O2; molecular filtration removes N2 from compressed room air in home care.
ch 13 slide 12
How does fractional distillation separate nitrogen from oxygen?
N2 and O2 have different boiling points; N2 evaporates, O2 collects at the tank bottom, and distillation continues until liquid is 99% O2.
In Simple Words: Nitrogen boils off first, leaving highly concentrated liquid oxygen.
ch 13 slide 13
What role does crystallized zeolite play in O2 concentrators?
From Slide: Home O2 concentrators use molecular filtration; crystallized zeolite filters nitrogen from compressed room air.
In Simple words:
Zeolite traps nitrogen so oxygen-rich gas can be delivered.
ch 13 slide 14
What flow rate and oxygen concentration do most home concentrators provide?
From Slide: Most concentrators run 1-5 LPM and deliver FiO2 of about 95-98%
In Simple words: Typical output is 1-5 liters per minute of roughly 95-98% oxygen.
ch 13 slide 14
What maintenance and backup precautions do home O2 concentrators need?
From Slide: Check routinely with an O2 analyzer and flow-measuring device; patients need a plan for power failure and spare O2 cylnders.
ch 13 slide 14
What are the combustion and metabolic properties of CO2?
From Slide: CO2 is nonflammable and does not support combustion or animal life/ it is a by-product of metabolism and burning carbonaceous fuels.
In simple words: CO2 will not burn or support breathing; bodies and burning fuels produce it.
ch 13 slide 15
Is pure CO2 therapeutic, and what are its other uses?
From slide: Pure CO2 is not used therapeutically; it can be used in carbonated drinks, fire extinguishers, or refrigerators.
In simple words: Pure CO2 is used in products and equipment, not as a breathing treatment.
ch 13 slide 15
What properties makes helium an important medical gas?
From Slide : Helium is rare, nonflammable, and the second lightest element; it is inert and does not cross the alveolar-capillary membrane.
In simple words: Helium is very light and does not readily move from alveoli into blood.
Why is helium considered a limited resource?
From Slide: Helium cannot be manufactured; its fixed quantity on Earth has been identified as a future critical shortage.
In simple words: Helium is a limited natural resource that may become scarce.
ch 13 slide 18
What are the two Heliox mixtures and the minimum O2 content?
From Slide: Heliox is helium mixed with oxygen; therapeutic mixtures are 70/30 or 80/20 He/O2, with at least 20 % oxygen.
ch 13 slide 19
When would we use heliox?
From Slide: Because of its light weight, heliox relieves work of breathing in severe bronchospasm (asthma) or upper airway obstruction.
IN simple words: Heliox helps air move through narrowed airways so breathing takes less effort.
ch 13 slide 19
How is nitric oxide (NO) characterized?
From Slide: Nitric oxide, or nitrogen monoxide, is nonflammable, supports combustion, and is not life-supporting; do not confuse with nitrous oxide.
In simple words: NO is a different gas from nitrous oxide; it cannot support breathing by itself.
ch 13 slide 20
What is the clinical purpose of inhaled nitric oxide?
From Slide: NO is used for selective pulmonary vasodilation, usually in neonates; it may be used off-label in adults.
In simple words: Inhaled NO relaxes blood vessels in the lungs, especially in newborn care.
ch 13 slide 20
What are the half-life and hemoglobin-related properties of NO?
From Slide: NO is highly diffusible and lipid-soluble, has a half-life of 3-50 seconds, and has a high affinity for hemoglobin.
In simple words: NO spreads quickly, acts briefly, and interacts strongly with hemoglobin.
ch 13 slide 20
How are medical gases stored in cylinders?
From slide: Steel or aluminum cylinders store and transport medical gases; some gases are stored as liquids or gases, and CO2 may liquefy under cylinder pressure.
In simple words: Gas cylinders come in different sizes; some contain compressed gas, and others contain liquid.
ch 13 slide 21
How do you calculate gas cylinder duration?
Slide: (tank pressure x tank factor) / flow rate
Simple: Multiply psi by the cylinder factor, then divide by L/min to get minutes.
ch 13 slide 4
How is remaining liquefied gas determined?
Slide: Cylinder weight is used because the gauge shows constant pressure.
Simple: Weigh a liquid-gas cylinder; its pressure gauge cannot show how much remains.
ch 13 slide 4
What does a cylinder conversion factor do?
Slide: Converts pressure reading (psi) to volume remaining (L).
Simple: It tells you how many liters of gas correspond to the cylinder pressure.
ch 13 slide 5
What are the O2 conversion factors for E and H/K cylinders?
Slide: E: 0.28, H or K: 3.14
Simple: Use 0.28 for E tanks and 3.14 for large H/K oxygen tanks.
ch 13 slide 5
What measures support safe medical gas cylinder use?
Slide: CGA guidelines, color-coding, markings, testing, standardized valves, indexing, and regulated filling.
Simple: Use clear identification, regular checks, correct connections, and safe handling rules.
ch 13 slide 9
How should medical gas cylinders be stored?
Slide: Cool, dry, ventilated, fire-resistant, secured storage; protected from weather and unauthorized access.
Simple: Keep cylinders in a safe, ventilated, locked area away from heat and hazards.
ch 13 slide 10
How should full and empty cylinders be organized?
Slide: Provide segregated, clearly labeled locations for full and empty cylinders.
Simple: Separate full tanks from empty ones so they cannot be mixed up.
ch 13 slide 10
How should large and small cylinders be secured?
Slide: Large cylinders upright with protective caps and restraints; small cylinders secured in racks, holders, or carts.
Simple: Keep big tanks upright and chained; secure smaller tanks so they cannot roll or fall.
ch 13 slide 10
How should E and H/K tanks be transported?
Slide: E tank: pull behind; H/K tank: push in front with chain in position.
Simple: Pull a small E-cylinder cart; push a secured large-cylinder cart ahead of you.
ch 13 slide 11
What safety precautions apply when handling cylinders?
Slide: Use lifting precautions; the regulator is not a handle.
Simple: Lift carefully and never carry a tank by its regulator.
ch 13 slide 11
How does a direct-acting cylinder valve work?
Slide: Turning the handle moves the stem and seat up or down, allowing gas through the port.
Simple: Turning the handle opens or closes the path for gas to escape.
What is the purpose of a pressure-relief device?
Slide: Controlled release of excess pressure; typically opens at 1.5 x normal filling pressure.
Simple: It vents dangerously high pressure to help prevent cylinder rupture.
ch 13 slide 17
What are the three types of safety relief valves?
Slide: Spring-loaded safety valve, frangible disc, and fusible plug.
ch 13 slide 18
How does a spring-loaded safety valve work?
Slide: When pressure exceeds the spring tension, gas is released through vents.
Simple: High pressure pushes against the spring, venting gas.
ch 13 slide 18
How do frangible discs and fusible plugs work?
Slide: Frangible disc breaks at excess pressure; fusible plug melts at excess temperature.
Simple: One bursts when pressure is too high; the other melts when too hot.
ch 13 slide 18
What are the two functions of a gas regulator?
Slide: Reduce tank pressure to working pressure; control O2 flow from the tank.
Simple: It lowers the pressure and lets you adjust oxygen flow.
How do single-stage and multistage regulators differ?
Slide: Most RT regulators are single-stage; multistage are less common and used for precise pressure and flow.
Simple: Single-stage is typical; multistage is for tighter control.
ch 13 slide 20
What happens inside a single-stage regulator?
Slide: Pressure is reduced in the pressure chamber so outlet pressure is 50 psi.
ch 13 slide 21
What are the three connection index safety systems?
Slide: Pin Index Safety System (PISS), American Standard Safety System (ASSS), Diameter index Safety System (DISS).
ch 13 slide 22
Which cylinder sizes use PISS and ASSS?
Slide: PISS: E tanks and smaller; ASSS: tanks larger than E.
ch 13 slide 22
What connections use DISS?
Slide: Low-pressure connections and fittings under 200 psi
ch 13 slide 22
What is the American Standard Safety System (ASSS)?
Slide: Threaded outlets of faucet-like valves on cylinders larger than E tanks.
ch 13 slide 25
What features make ASSS connections gas-specific?
Slide: Outlet diameter, threads/inch, Thread direction, internal/external threads, and regulator shape.
Simple: Each gas has a particular thread and fitting pattern to avoid mix-ups.
ch 13 slide 25
Why do facilities use bulk liquid oxygen?
Slide: Liquid oxygen stores a large volume; 1 L liquid O2 = 861 L gaseous O2
ch 13 slide 28
What conditions maintain bulk oxygen as a liquid?
Slide -118 C and 716 psi.
ch 13 slide 28
How is liquid oxygen converted to gas?
Slide: It passes through evaporator coils that warm it above its boiling point.
ch 13 slide 28
How much reserve oxygen should a facility have?
Slide: Reserve supply equal to one day of average O2 use.
cha 13 slide 29
What should facilities plan for oxygen supply failure?
Slide: Procedures and emergency protocols for response to O2 supply failure.
ch 13 slide 29
How is medical gas distributed within a facility?
Slide: Through pipes, valves, and outlets; pipes labeled at regular intervals.
ch 13 Slide 31
What pressure must the gas piping system maintain?
Slide: 50 psi throughout the entire system
ch 13 slide 31
How do primary shuttoff and zone valves differ?
Slide: Primary: where the main pipe leaves the bulk supply; zone: isolate specific areas for fire, maintenance, or construction.
ch 13 s;ode 31
How many one-way valves are on a true non-rebreather?
Slide: Three: two on the mask and one between the O2 reservoir and mask.
ch 14 slide 37
What do the two mask valves do on a true NRB?
Slide: Close on inhalation to decrease room air entrainment and open on exhalation.
Simple: They keep room air out when breathing in and out.
ch 14 slide 37
What does the reservoir valve do on a true NRB?
Slide: Opens on inhalation to breathe from reservoir; closes on exhalation to force air through mask valves.
Simple: It lets oxygen in from the bag and prevents exhaled gas from entering the bag.
ch 14 slide 37
What makes a partial non-rebreather different?
Slide: At least one mask one-way valve is removed; potentially no one-way valves remain.
Simple: A partial NRB has fewer valves than a true NRB.
ch 14 Slide 38
What valve configurations can a partial NRB have?
Slide: Examples: one valve between the bag and mask, or one mask valve plus one bag-to-mask valve.
ch 14 slide 38
What flow rate and claimed FiO2 does an OxyMask provide?
Slide: Flow rate 1-15 LPM; claims FiO2 25-90%
Why is OxyMask FiO2 variable?
Slide: It is a low-flow device with no O2 reservoir and large holes that dilute FiO2 with room air.
ch 14 Slide 42
What defines a high-flow oxygen device?
Slide: Total flow meets or exceeds the patient’s inspiratory flow rate.
ch 14 slide 44
Why can high-flow devices deliver accurate FiO2?
Slide: Correct setup prevents dilution of FiO2 with room air.
ch 14 slide 44
What are three indications for high-flow oxygen?
Slide: pts have increased inspiratory flow with need for accurate FiO2; flow-hungry patients (typically COPD); humidity via LVN.
ch 14 Slide 44
How do you titrate high-flow oxygen for oxygenation?
Slide: Adjust FiO2 per ABG or pulse ox; recalculate total flow after each change and keep it at or under 30 LPM.
ch 14 Slide 45
How do you titrate high-flow oxygen for comfort?
Slide: Increase the flowmeter to increase total flow without changing FiO2; minimum total flow: 30 LPM.
Simple: Give a flow-hungry patient more gas without raising the oxygen percentage.
ch 14 slide 45
How do air-entrainment devices increase total flow?
Slide: Venturi principle: O2 through the venturi draws room air through a port; window/restriction size affects entrainment.
What minimum total flow is needed for adult air-entrainment devices?
Slide: At least 30 LPM; use the magic box to calculate total flow.
ch 14 Slide 46
How is total flow calculated at 60% Fi02?
Slide: 60% Fi02 yields a 1:1 air-to-O2 ratio; total flow is twice the flowmeter setting
Rule of thumb: For an FiO2 of 60%, always set flowmeter at 15LPM or greater
ch 14 slide 49
What flowmeter setting is recommended at 60% FiO2?
Slide: Always set the flowmeter at 15 LPM or greater.
How do you check adequate flow when FiO2 exceeds 60%?
Slide: Increase flow until the aerosol is constant during inspiration and expiration; one setup cannot calculate total flow.
Simple: if mist disappears during inhalation, the patient needs more flow.
ch 14 slide 49
What is the function of an oxygen analyzer?
Slide: Analyzes FiO2 to determine accuracy of FiO2 delivered to the patient.
ch 14 Slide 51
How do you calibrate an oxygen analyzer?
Slide: Two-point calibration before use: room air and 100% O2.
ch 14 Slide 51
Where should the oxygen analyzer be placed?
Slide: Near the patient, with 6 inches of large-bore tubing between analyzer and patient.
ch 14 slide 51
When is a Venturi mask indicated and what is its FiO2 range?
Slide: For flow-hungry patients; FiO2 24%-50% (sometimes 55%, depending on brand).
ch 14 slide 52
What are key considerations when using a Venturi mask?
Slide: It is dry; ensure total flow meets or exceeds the patient’s inspiratory flow.
Simple: watch for dryness and make sure flow meets breathing demand.
ch 14 slide 52
What FiO2 range an an LVN deliver?
Slide: Large volume nebulizers deliver about 28-100% FiO2; they can also use room air only.
When are cool versus warm LVNs indicated?
Slide: Cool: Stridor or upper airway swelling. Warm: Copious secretions or trach tube.
ch 14 slide 54
What setup precautions are important for an LVN?
Slide: Fill with sterile water; put the drain bag at the lowest tubing point; rainout adds resistance and decreases total flow.
ch 14 slide 54
How can an LVN deliver FiO2 below its lowest setting?
Slide: Set LVN to room air at or below 30 LPM; use analyzer near patient; bleed O2 near outlet to desired FiO2.
How is total flow calculated when oxygen is bled into an LVN?
Slide: Calculate LVN setup total flow, then add the supplemental O2 flow rate.
ch 14 Slide 55
How can two LVNs be combined for FiO2 above 60%?
Slide: Wye two high-flow setups; match FiO2 and flowmeter settings; calculate one setup’s flow and double it.
What is total flow for two 70% LVNs at 12 LPM each?
Slide: One setup = 19.2 LPM; two setups = 19.2 × 2 = 38.4
What are the main components of HFNC?
Slide: Large-bore nasal prongs, heated passover humidifier, wired circuit, and air-O2 blender.
ch 14 slide 59
What FiO2 and flow can HFNC deliver?
Slide: FiO2 21-100%; flow 0-60 LPM; set FiO2 and total flow directly without the magic box.
How does hyperbaric oxygen therapy work?
Slide: Patient in an airtight chamber pressurized to greater than 1 atm, usually at 100% FiO2; greatly raises PAO2 and PaO2
ch 14 slide 61
What are HBO indications and a major risk?
Slide: Carbon monoxide poisoning, wound healing, decompression sickness; high risk of O2 toxicity.
ch 14 Slide 61
When is heliox indicated?
Slide: Partial upper airway obstruction (stridor, laryngeal mass, croup, edema) or asthma/bronchospasm.
ch 14 slide 62
Does Heliox correct the cause of obstruction?
Slide: Heliox improves gas flow but is a supportive band-aid; the actual problem must be fixed.
ch 14 slide 62
What are Heliox oxygen-flowmeter conversion factors?
Slide: 70/30 heliox: 1.6; 80/20 heliox: 1.8; actual flow exceeds indicated oxygen-meter flow
ch 14 slide 64
How do you calculate actual flow for 80/20 Heliox at 15 LPM?
Slide: 15 LPM x 1.8 = 27 LPM actual flow.
ch 14 Slide 64
What meter setting gives 16 LPM of 70/30 Heliox?
Slide: 16 LPM/1.6 = 10 LPM on an O2-calibrated flowmeter.
ch 14 slide 64
What is inhaled nitric oxide (iNO)?
Slide: A selective pulmonary vasodilator that reduces pulmonary vascular resistance without changing systemic resistance.
ch 14 slide 65
Which vessels are dilated by inhaled nitric oxide?
Slide: Only the vasculature of ventilated alveoli.
ch 14 slide 65