1/39
Looks like no tags are added yet.
in vivo
research performed within the living body
in vitro
research performed outside of the living body (could be in an artificial environment)
dosimetry
science of studying ultrasound beam characteristics relevant to biological effects
mechanistic approach
searches for relationship between cause and effect
empirical approach
searches for relationship between exposure and response
prospective studies
individuals are studied over time
retrospective stuidies
looks backward and evaluates data that has already been gathered
epidemiology
study of health outcomes in populations
american institute of ultrasound in medicine (AIUM)
promotes ultrasound research, education, and safe clinical practice
food and drug administration (FDA)
regulates ultrasound equipment, establishes and enforces safety standards for diagnostic use
ALARA
as low as reasonable achievable
hydrophone
measures pressure of sound waves - gold standard
force balance
measures the power of the sound wave
calorimeter
measures total power in sound beam through absorption (measures temperature rise and time of heating)
thermocouple
measures the beam’s power at specific locations in beam
liquid crystals
crystals absorb beam and change color based on temp
intensity units
watts/cm²
highest value common intensity
ISPTP
lowest value common intensity
ISATA
common intensity associated with tissue heating
ISPTA
Pulse intensity measurements are made during
Pulse duration (PD)
temporal intensity measurements are taken over the
pulse repetition period (PRP)
duty factor =
pd/ prp = ta/pa
when will pulse intensity and temporal intensity be the same?
continuous wave doppler
thermal bioeffects
tissue heating caused by absorption of ultrasound energy - thermal index
mechanical bioeffects
related to cavitation - stable and inertial/ transient/ normal
no thermal bioeffects have resulted in adverse effects when the tissue temp has increased less than
2 degrees celsius
thermal index
estimated max temp increase for the current imaging situation
fetal imaging thermal index
begin with < or equal to 0.7
nonfetal imaging thermal index
maintain TI <0.6 when possible
scanned modalities
beam continuously moves across tissue - 2D (lowest), color Doppler
nonscanned modalities
beam repeatedly insonates the same tissue region - CW, PW(highest), MMode
mechanical index
used to calculate the likelihood of mechanical bioeffects
mi increases when
1. frequency decreases 2. peak rarefactional pressure increases
higher MI indicates
greater cavitation potential
SPTA is limited to _______ in unfocused ultrasound
100 mW/cm²
SPTA is limited to _______ in focused ultrasound
1000 mW/cm²
typical SPTA output for diagnostic ultrasound systems is
1 mW/cm²
CW: beam always on, PD = PRP
PA = TA — SPTA = SPPA — SATA = SAPA
beam uniformity factor
also called beam uniformity coefficient or SP/SA factor
how US intensity is distributed across the beam
BUC = SP/SA