Unit 5 Terms and Concepts

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/39

encourage image

There's no tags or description

Looks like no tags are added yet.

40 Terms

1
New cards

in vivo

research performed within the living body

2
New cards

in vitro

research performed outside of the living body (could be in an artificial environment)

3
New cards

dosimetry

science of studying ultrasound beam characteristics relevant to biological effects

4
New cards

mechanistic approach

searches for relationship between cause and effect

5
New cards

empirical approach

searches for relationship between exposure and response

6
New cards

prospective studies

individuals are studied over time

7
New cards

retrospective stuidies

looks backward and evaluates data that has already been gathered

8
New cards

epidemiology

study of health outcomes in populations

9
New cards

american institute of ultrasound in medicine (AIUM)

promotes ultrasound research, education, and safe clinical practice

10
New cards

food and drug administration (FDA)

regulates ultrasound equipment, establishes and enforces safety standards for diagnostic use

11
New cards

ALARA

as low as reasonable achievable

12
New cards

hydrophone

measures pressure of sound waves - gold standard

13
New cards

force balance

measures the power of the sound wave

14
New cards

calorimeter

measures total power in sound beam through absorption (measures temperature rise and time of heating)

15
New cards

thermocouple

measures the beam’s power at specific locations in beam

16
New cards

liquid crystals

crystals absorb beam and change color based on temp

17
New cards

intensity units

watts/cm²

18
New cards

highest value common intensity

ISPTP

19
New cards

lowest value common intensity

ISATA

20
New cards

common intensity associated with tissue heating

ISPTA

21
New cards

Pulse intensity measurements are made during

Pulse duration (PD)

22
New cards

temporal intensity measurements are taken over the

pulse repetition period (PRP)

23
New cards

duty factor =

pd/ prp = ta/pa

24
New cards

when will pulse intensity and temporal intensity be the same?

continuous wave doppler

25
New cards

thermal bioeffects

tissue heating caused by absorption of ultrasound energy - thermal index

26
New cards

mechanical bioeffects

related to cavitation - stable and inertial/ transient/ normal

27
New cards

no thermal bioeffects have resulted in adverse effects when the tissue temp has increased less than

2 degrees celsius

28
New cards

thermal index

estimated max temp increase for the current imaging situation

29
New cards

fetal imaging thermal index

begin with < or equal to 0.7

30
New cards

nonfetal imaging thermal index

maintain TI <0.6 when possible

31
New cards

scanned modalities

beam continuously moves across tissue - 2D (lowest), color Doppler

32
New cards

nonscanned modalities

beam repeatedly insonates the same tissue region - CW, PW(highest), MMode

33
New cards

mechanical index

used to calculate the likelihood of mechanical bioeffects

34
New cards

mi increases when

1. frequency decreases 2. peak rarefactional pressure increases

35
New cards

higher MI indicates

greater cavitation potential

36
New cards

SPTA is limited to _______ in unfocused ultrasound

100 mW/cm²

37
New cards

SPTA is limited to _______ in focused ultrasound

1000 mW/cm²

38
New cards

typical SPTA output for diagnostic ultrasound systems is

1 mW/cm²

39
New cards

CW: beam always on, PD = PRP

PA = TA — SPTA = SPPA — SATA = SAPA

40
New cards

beam uniformity factor

also called beam uniformity coefficient or SP/SA factor
how US intensity is distributed across the beam
BUC = SP/SA