1/44
Comprehensive vocabulary flashcards covering recruit firefighter curriculum: water safety, knots, hazardous materials, building alarms, breathing apparatus, communications, hydraulics, aviation, road rescue, wildfire behavior, and fundamental fire science.

Defensive Swimming Position
A self-rescue posture where the swimmer floats on their back facing downstream with feet near the surface to navigate currents, protect the head and spine from obstacles, and prevent foot entrapment.
Dry Rescue Techniques
Three non-entry water rescue methods used to assist a casualty: Yell (providing instructions and reassurance), Reach (using a pole from a stable edge), and Throw (deploying a throw bag from a dry position).
Water Proximity Life Jacket Threshold
The operational requirement dictating that all crew members must wear life jackets when working over water or within a distance of 2 metres.
TRUSS
An acronym defining the characteristics of an effective knot: Tie (easy to tie), Recognisable (easily verified if tied correctly), Untie (easy to untie), Slip (will not slip excessively), and Strength (will not significantly reduce rope strength).
Emergency Information Panel (EIP)
A standardized transport placard displaying six essential data points: Chemical name, UN Number, HAZCHEM Code, emergency services contact number, Dangerous Goods Class, and contact number for specialist advice.
Hydrogen Sulfide (H2S)
A hazardous gas identified by three core physical and chemical properties: colourless appearance, high flammability, and a distinct rotten egg odor.
DANGER (HAZMAT Protocol)
An initial operational response acronym: D (Do not enter clouds), A (Approach upwind and uphill), N (No closer than 70 metres), G (Gather information from a distance), E (Examine with full PPE only if necessary), and R (Respond accordingly).
Five-Step HAZMAT Approach
The sequential process for managing hazardous material scenes: 1. Initial Consideration, 2. Cold Zone Reconnaissance (from 70 m), 3. Hot Zone Reconnaissance, 4. Mitigation, and 5. Handover to regulatory authorities.
HAZMAT Information Hierarchy
The structured escalation of incident reference data from lowest to highest level: Safe Approach (Level 1), HAZCHEM EAC (Level 2), ANZERG (Level 3), HAG Sheet (Level 4), SDS (Level 5), and Technical Specialists (Level 6).
Levels of Chemical Protective Clothing
Classification of protective suits: Level A (gas-tight, fully encapsulating with BA), Level B (chemical splash, non-encapsulating with BA), and Level D (standard structural turnout gear or station workwear).
Hazardous Materials
Substances or materials in forms or quantities that present an unreasonable threat to health, life, property, or the environment during commercial storage, use, or transport, comprising both dangerous goods and hazardous substances.
Smoke Detector Types
The four main mechanisms of early smoke detection: Point Type (ionisation or photoelectric), Beam Type, Air Sampling Type, and Household Type (ionisation or photoelectric).
Victorian Smoke Alarm Standard (AS 3786)
State legislation requiring alarms on all storeys, specifying at least a 9V battery alarm for homes constructed prior to 1 August 1997, and a hardwired 240V mains-powered alarm with battery backup for homes constructed thereafter.

Alarm Signalling Equipment (ASE) Relay Sequence
The automated alert pipeline where facility inputs (FIP, VMA, SPR) route signals to the ASE, which sequentially notifies (1) the private Monitoring Company, (2) ESTA, and (3) Fire Services to dispatch responding appliances.
Automatic Sprinkler System Core Functions
The four operational objectives of an automatic system: detect fire, initiate suppression attack, contain or extinguish the blaze, and transmit alarms to occupants and the fire service.
Sprinkler Water Supply Sources
The five recognized water sources for automatic installations: town water mains, gravity tanks, ground-level reservoirs with automatic pumps, elevated private reservoirs, and dedicated pressure tanks.
DEBRiS (OMS 024)
An operational management framework: D (Decontamination), E (Entry/Exit controls), B (Breathing Apparatus servicing), R (Rehabilitation and AV monitoring), i (Incident accountability), and S (Staging Area for personnel and appliances).
HOTS (Respiratory Hazards)
The primary atmospheric hazards encountered inside fire environments: High air temperature, Oxygen deficiency, Toxic atmospheres, and elevated Smoke concentration.
Breathing Apparatus Working Duration
The usable operational time inside a hazard zone calculated by dividing total cylinder air volume by a standard consumption rate of 60L/min and subtracting a mandatory 10-minute safety exfiltration reserve.
Fireground Mayday Protocol
The emergency distress broadcast transmitted when a member is lost or trapped, consisting of repeating 'Mayday' three times, caller name, appliance call sign, exact location, and a CAN (Conditions, Actions, Needs) SitRep.
Structure Fire Message Sequence
The chronological reporting cycle during a structural assignment: Turn out, On Scene, Wordback, SitRep, Returning, and In Station.
Low Water Level Warning System
An automated tank monitoring alarm that activates below 41 capacity and clears above 43 capacity, signaling via roof strobes, dash indicators, and audible alerts (20 s for MkV; 5 s for Heavy Pumper).
Relay Pumping Relief Valves
The hydraulic roles assigned during relay pumping where the supply pumper adjusts the pressure relief valve and the receiving pumper adjusts the suction relief valve.
Pilot Operated Pressure Relief Valve
A protective bypass mechanism that shunts excess water from delivery to suction to prevent pressure surges upon line shutoff, acting as a failsafe against pressures exceeding 1400kPa.

Hose Friction Loss Rates
Standard friction loss figures: 38mm hose at 500L/min experiences 220kPa; 50mm at 750L/min experiences 220kPa; 65mm at 750L/min experiences 55kPa; 65mm at 1000L/min experiences 100kPa; and 90mm at 2000L/min experiences 100kPa.
Liquefied Petroleum Gas (LPG) Properties
A hydrocarbon fuel filled to a maximum legal capacity of 80% to permit vapour expansion, characterized by a 270:1 expansion ratio, a relative vapour density of 1.5 (heavier than air), and a flammability range between 2% and 10%.
AIRMEN (Aviation Firefighting)
An aviation crash response tactic: Approach (from nose or tail), Insulate/isolate (cabin areas with foam/water), Rescue path (clear door access), Maintain path (protect egress), Evacuate (passengers immediately), and Next appliance (act as support).

Aircraft Tyre Burst Hazard Zone
The dangerous lateral perimeter extending 180 metres directly outward from an aircraft landing gear assembly that personnel must avoid due to the risk of explosive wheel failure during a brake fire.
Extinguisher Colour Identification
Colour coding standards: solid red denotes water; red with a white band denotes dry powder; red with a black band denotes carbon dioxide; and solid blue or red with a blue band denotes foam.
Motor Vehicle Accident (MVA) Control Agencies
The jurisdictional assignment where the State Emergency Service (SES) acts as the control agency for road crash rescues, while Fire Rescue Victoria (FRV) assumes control if the incident involves fire or hazardous materials.
MVA Scene Boundary Estimation
The practice of establishing perimeter control by encompassing an area slightly larger than the location of the furthest piece of physical debris or evidence.
Structural Collapse Indicators
Physical warning signs of failure including sagging ceilings or floors, spongy deck spring, sounds of timber or masonry movement, smoke exiting mortar joints, bowing exterior walls, and cracks appearing above openings.
Salvage
The active fireground practice of preventing or minimizing secondary structural and property damage caused by heat, smoke, water, debris, dust, and physical breakage.
Overhaul
The complete post-fire inspection process aimed at locating hidden fire, preventing rekindling, establishing the fire's origin and cause, preserving evidence of crime, and leaving the structure in a safe condition.
Positive Pressure Ventilation (PPV)
A tactical ventilation method that forces clean exterior air into a structure with mechanical blowers to rapidly displace heat and smoke through exhaust points, equalizing room pressure and improving interior visibility.

Wildfire Anatomy (A through F)
The anatomical zones of an advancing bushfire: A (Rear/Heel), B (Side/Flank), C (Finger), D (Head Fire), E (Spot Fire), and F (Point of origin).
Ember Attack
The primary bushfire mechanism of structural destruction where wind-blown burning materials lodge into roof cladding, open windows, gutters, exterior wall vents, underfloor voids, or combustible outdoor decks.
Heat Stress Prevention Fluid Ratio
Hydration management calling for at least 1 litre of fluid per hour during hard physical work, consumed at a ratio of 700ml of water to 300ml of electrolyte replacement drink.
Red Flag Warning Protocol
A mandatory fireground broadcast procedure requiring the recipient to immediately acknowledge the transmission, repeat key points back, notify subordinates, gather receipt confirmation, and record details in writing.
Flashover
The sudden and sustained thermal transition inside a compartment from the developing stage to the fully developed fire stage, where all exposed combustible surfaces ignite simultaneously.
Backdraught
An explosive deflagration caused by the sudden introduction of oxygen into an oxygen-starved, superheated compartment containing unburned pyrolysis gases.
Fire Gas Ignition
The ignition and rapid burn of an accumulated, pre-mixed cloud of flammable fire gases and air located in a compartment (often isolated from the initial fire room) once exposed to a spark or flame.
Gas Cooling Pulse Techniques
Nozzle applications where short pulses dilute and cool overhead gases to prevent them from reaching auto-ignition temperature, while long pulses aggressively drive water droplets deep into large compartments ahead of entering crews.
B-SAHF Smoke Indicators
The four observable traits of smoke used to read fire behavior: Volume (fuel amount involved), Velocity (heat release rate and laminar/turbulent flow), Density (fuel thickness and incomplete combustion), and Colour (stage of pyrolysis and combustion).
Flammable Ranges of LPG and CO
The flammability metrics: LPG has an LEL of 2%, an Ideal Mixture of 4%, and a UEL of 10%, whereas Carbon Monoxide (CO) has an LEL of 12.5%, an Ideal Mixture of 28.4%, and a UEL of 74%.