1/188
Looks like no tags are added yet.
Navier–Stokes equation
Fluid equation of motion that balances inertia with pressure, gravity, and viscous forces.
Navier–Stokes x-direction
ρ(∂u/∂t + u∂u/∂x + v∂u/∂y + w∂u/∂z) = ρgx − ∂p/∂x + μ(∂²u/∂x² + ∂²u/∂y² + ∂²u/∂z²).
What does the left side of Navier–Stokes represent?
Fluid inertia or acceleration: ρ(Du/Dt).
What does −∂p/∂x represent?
Force caused by the pressure gradient.
What does ρgx represent?
Body force due to gravity in the x-direction.
What does the μ∇²u term represent?
Viscous effects caused by velocity gradients.
Steady-flow simplification
Steady flow means ∂u/∂t = 0.
Fully developed flow simplification
If flow is fully developed in x, ∂u/∂x = 0.
Fully developed viscous-term simplification
If ∂u/∂x = 0 everywhere, then ∂²u/∂x² = 0.
Unidirectional flow simplification
If V = u(y)i, then v = 0 and w = 0.
One-dimensional plate-flow assumption
For u = u(y), velocity varies only with y.
Horizontal-flow gravity simplification
If x is horizontal, gx = 0.
No pressure-gradient simplification
If pressure is constant in x, ∂p/∂x = 0.
Pressure-driven parallel-plate flow
0 = −dp/dx + μ d²u/dy².
Couette flow equation
For no pressure gradient, d²u/dy² = 0
Couette velocity profile
For bottom wall fixed and top wall speed U: u(y) = Uy/b.
Poiseuille flow between plates
Flow driven by a pressure gradient between stationary parallel plates
Combined Couette–Poiseuille flow
u(y) = Uy/b + (1/(2μ))(dp/dx)(y² − by).
Maximum velocity condition
Velocity is maximum where du/dy = 0.
No-slip boundary condition
Fluid velocity equals the velocity of the wall.
Stationary-wall boundary condition
At a stationary wall, u = 0.
Moving-wall boundary condition
At a wall moving at speed U, fluid velocity at the wall is u = U.
Euler equation
Euler is Navier–Stokes with viscosity neglected: ρDV/Dt = −∇p + ρg.
When can Navier–Stokes become Euler?
When viscous effects are negligible
Fully developed laminar pipe-flow equation
0 = −dp/dx + μ(1/r)d/dr(r du/dr).
Pressure-driven pipe flow
A negative pressure gradient, dp/dx < 0, drives flow in the +x direction.
Similitude
Using a model to predict the behavior of a full-size prototype.
Model
Smaller or modified system used to represent a real system.
Prototype
The real full-size system being modeled.
Geometric similarity
Model and prototype have the same shape and proportional dimensions.
Kinematic similarity
Model and prototype have similar velocity and motion patterns.
Dynamic similarity
Model and prototype have the same important force ratios.
Scale ratio
Ratio of a model quantity to the corresponding prototype quantity.
Reynolds number
Dimensionless ratio of inertial effects to viscous effects; Re = ρVL/μ
Reynolds similarity
Model and prototype have equal Reynolds numbers
Froude number
Dimensionless ratio involving inertia and gravity; Fr = V/√(gL).
Froude similarity
Used when gravity or free-surface effects are important.
Mach number
Ratio of flow speed to speed of sound; Ma = V/c.
Mach similarity
Used when fluid compressibility is important.
Strouhal number
Dimensionless frequency parameter; St = fL/V.
Strouhal similarity
Used when oscillation, rotation, or periodic flow is important
Euler number
Dimensionless pressure parameter comparing pressure effects to inertia.
Laminar flow
Ordered fluid motion with smooth layers and little mixing
Transitional flow
Pipe-flow regime between laminar and turbulent behavior
Turbulent flow
Irregular flow with velocity fluctuations and strong mixing.
Laminar pipe-flow range
Approximately Re < 2300
Transitional pipe-flow range
Approximately 2300 < Re < 4000.
Turbulent pipe-flow range
Approximately Re > 4000.
No-slip condition
Fluid velocity at a stationary solid wall is zero.
Entrance region
Region where the pipe velocity profile is still developing.
Fully developed flow
Velocity profile shape no longer changes in the flow direction.
Fully developed condition
For pipe flow, ∂u/∂x = 0.
Velocity profile
Variation of fluid velocity across a pipe or boundary layer.
Laminar pipe velocity profile
Parabolic velocity distribution with maximum speed at the center
Maximum laminar pipe velocity
For fully developed laminar pipe flow, umax = 2Vaverage.
Poiseuille flow
Steady, fully developed laminar pipe flow driven by a pressure gradient.
Pressure gradient
Change in pressure with distance; pressure decreases in the direction of passive pipe flow.
Hagen-Poiseuille equation
Relates laminar pipe flow rate to pressure drop, viscosity, length, and radius
Darcy friction factor
Dimensionless factor used to calculate pipe friction losses
Laminar friction factor
For laminar circular-pipe flow, f = 64/Re.
Relative roughness
Ratio of pipe roughness to diameter; ε/D
Moody chart
Chart used to determine Darcy friction factor from Re and ε/D.
Major loss
Energy loss caused by wall friction along a length of pipe
Darcy-Weisbach equation
Major head loss: hL = f(L/D)(V²/2g).
Head loss
Loss of mechanical energy per unit weight of fluid
Minor loss
Energy loss caused by fittings, bends, valves, entrances, exits, expansions, or contractions.
Loss coefficient KL
Dimensionless coefficient describing the energy loss of a fitting
Minor-loss equation
hL = KL(V²/2g).
Total pipe loss
Sum of major friction losses and all minor losses
Sharp-edged entrance
Entrance that causes flow separation and a relatively large minor loss
Pipe exit loss
For discharge into a large reservoir, typically KL = 1
Sudden expansion
Abrupt increase in pipe area that causes separation and energy loss.
Sudden contraction
Abrupt decrease in pipe area that causes separation and energy loss
Valve loss
Minor loss caused by flow through a valve
Hydraulic diameter
Equivalent diameter for noncircular ducts; Dh = 4A/P
Wetted perimeter
Perimeter of a duct cross-section that is in contact with the fluid
Pump head
Mechanical energy per unit weight added to a fluid by a pump
Turbine head
Mechanical energy per unit weight removed from a fluid by a turbine
Extended energy equation
Bernoulli equation modified to include pumps, turbines, and head losses.
Kinetic-energy correction factor α
Corrects the V²/2g term for a nonuniform velocity profile.
Uniform velocity profile correction
For a uniform profile, α = 1.
Laminar pipe correction factor
For fully developed laminar circular-pipe flow, α = 2
Flow meter
Device used to determine fluid flow rate
Venturi meter
Flow meter using a smooth constriction and pressure difference to determine flow rate.
Orifice meter
Flow meter using a sharp-edged plate and pressure difference to determine flow rate.
Flow nozzle
Flow meter that accelerates fluid through a nozzle and uses pressure difference.
Discharge coefficient Cd
Correction factor accounting for differences between ideal and real flow-meter behavior.
Diameter ratio β
Ratio of throat diameter to pipe diameter in a flow meter.
Rotameter
Vertical variable-area flow meter containing a floating element
Turbine flow meter
Flow meter that determines flow rate from the rotation rate of a turbine
External flow
Fluid flow around an object rather than through a pipe
Free-stream velocity V∞
Fluid velocity far enough from an object that the object has little effect on it.
Boundary layer
Thin region near a surface where viscous effects and velocity gradients are important.
Boundary-layer thickness
Distance from the wall over which velocity approaches the free-stream velocity.
Displacement thickness
Represents the effective loss of flow rate caused by the boundary layer.
Boundary-layer separation
Point where the boundary layer detaches from the surface.
Wake
Low-speed disturbed region downstream of a body caused by separation.
Drag
Fluid force acting parallel to the free-stream direction.
Lift
Fluid force acting perpendicular to the free-stream direction.
Skin-friction drag
Drag caused by viscous shear stress acting along a surface