Lab 2 - SEC Chromatography

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/23

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 5:24 PM on 9/29/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

24 Terms

1
New cards

What does size exclusion chromatography (SEC) separate molecules based on?

Molecular size

2
New cards

What is the stationary phase?

The porous resin/beads packed inside the column

3
New cards

What is a fraction?

A portion of liquid collected as it exits the chromatography column

4
New cards

Which molecules elute first in SEC?

Larger molecules

5
New cards

Which molecules elute later?

Smaller molecules

6
New cards

Why do large molecules move through SEC faster?

They cannot enter the bead pores, so they take a shorter path around them

7
New cards

Why do smaller molecules move through SEC more slowly?

They enter the resin/bead pores, giving them a longer path through the column

8
New cards

What 2 molecules did we separate using SEC?

Hemoglobin and Vitamin B12

9
New cards

Approximately how large is hemoglobin?

~65,000 Da

10
New cards

Approximately how large is vitamin B12?

~1,350 Da

11
New cards

What color was the hemoglobin?

Red-brown

12
New cards

What color was the vitamin B12?

Pink

13
New cards

What should elute first: hemoglobin or B12?

Hemoglobin

14
New cards

Why does hemoglobin elute before B12?

Hemoglobin is much larger and is excluded from bead pores, so it travels through the column faster.

15
New cards

You observe a red-brown early fraction. What is likely present?

Hemoglobin

16
New cards

You observe a pink late fraction. What is likely present?

B12

17
New cards

What was the approximate exclusion limit of the SEC column?

~60,000 Da

18
New cards

What was done with the storage buffer initially inside the SEC column?

It was drained into the waste tube

19
New cards

How much protein mixture was initially loaded?

One drop

20
New cards

Why was the protein mixture loaded carefully onto the top of the column bed?

To avoid disturbing the resin bed and compromising the separation.

21
New cards

What was added after the protein entered the column bed?

250uL of column buffer, followed by another 250uL after draining

22
New cards

What was added after those initial washed?

3 mL column buffer

23
New cards

How many drops were collected in tubes 2-9?

5 drops per tube

24
New cards

How many drops were collected in tube 10?

10 drops or remainder of liquid