1/97
Looks like no tags are added yet.
What are common patient assessment tools?
Stethoscope, pulse oximeter, BP cuff, thermometer, transcutaneous monitor, and end-tidal CO2.
What is the purpose of patient assessment equipment?
To put measurable values to the visual "from the door" assessment.
What does a pulse oximeter measure?
Oxygen saturation of hemoglobin in the blood.
Is pulse oximetry invasive or noninvasive?
Noninvasive.
What are three indications for pulse oximetry?
Monitor arterial oxyhemoglobin saturation, evaluate treatment, and evaluate tolerance of diagnostic procedures.
What principle does a pulse oximeter use?
Spectrophotometric light absorption.
What two wavelengths of light does an oximeter transmit?
Red and infrared.
What absorbs some of the light from a pulse oximeter?
Skin, fat, muscle, and venous blood.
What type of blood flow is used to determine arterial oxygen saturation?
Pulsatile arterial blood flow.
Why can pulse oximetry distinguish oxygenated from reduced Hb?
They absorb light differently.
What does pulse oximetry determine?
The degree of oxygen saturation.
What does oxygen saturation represent?
The areas of hemoglobin binding capacity occupied by oxygen.
What is the ideal oxygen saturation for a healthy adult according to the notes?
Above 92%.
What saturation is noted for healthy neonates?
Above 95%.
Why can carbon monoxide poisoning make SpO2 misleading?
CO displaces oxygen from hemoglobin while the oximeter may still display high saturation.
What are factors that can affect pulse oximeter accuracy?
Motion, sensor misalignment, dysfunctional Hb, low perfusion, ambient light, dyes, skin pigmentation, and nail polish.
What is functional saturation?
The amount of Hb saturated compared with Hb capable of being saturated.
How can anemia contribute to hypoxia?
There is insufficient oxygen delivery to tissues.
What does low perfusion indicate?
Low blood flow, such as from low blood pressure.
What is a potential concern with a forehead oximeter probe?
Poor perfusion and risk of skin burns.
What are advantages of pulse oximetry?
It is quick, noninvasive, and can correlate well with laboratory values.
When can pulse oximetry be accurate according to the notes?
With adequate cardiac output and saturation above 65%.
What conditions can cause erroneous pulse oximeter values?
Low cardiac output, shunting, hypothermia, high bilirubin, COHb/MetHb, dark pigmentation, and dyes.
What dyes can interfere with pulse oximetry?
Indocyanine green and methylene blue.
Why is hypothermia a problem for pulse oximetry?
Poor perfusion makes obtaining a reading more difficult.
Why is monitoring site selection important?
Motion and perfusion affect accuracy.
Where is a pulse oximeter usually placed?
Finger; sometimes toe, earlobe, or forehead.
Does normal SpO2 always mean adequate oxygen delivery to tissues?
No.
What does pulse oximetry not measure?
PCO2 or acid-base status.
What should you consider when selecting a pulse oximeter site?
Motion and perfusion.
How can you improve a pulse oximeter reading if the site is cold?
Warm the site with a warm towel or cloth.
How should the pulse oximeter site be cleaned?
With an alcohol prep pad.
How should the pulse oximeter probe be cleaned?
With an alcohol prep pad.
What should you do if the pulse oximeter probe is misaligned?
Check placement and adjust or move it to another site.
What should be done if nail polish interferes with pulse oximetry?
Remove the nail polish and reapply the probe.
What should you do if troubleshooting does not correct the reading?
Replace the probe.
How can ambient light interference be reduced?
Shield the probe from ambient light.
What is transcutaneous monitoring used for?
Continuous monitoring and real-time response to intervention.
What are contraindications to transcutaneous monitoring?
Poor skin integrity or adhesive allergy.
What are precautions with transcutaneous monitoring?
False-negative/positive results and tissue injury.
What are common sites for transcutaneous monitoring?
Abdomen, chest, and lower back.
Which patients commonly use transcutaneous monitoring?
Neonates.
Where else is transcutaneous monitoring used?
Sleep labs during polysomnography testing.
Why are abdomen, chest, and lower back common monitoring sites?
They provide large, relatively fatty areas.
What is transcutaneous monitoring used more for?
CO2 monitoring.
How does heating the skin affect transcutaneous CO2 monitoring?
It slightly increases skin permeability and CO2 diffusion.
What is a risk of transcutaneous monitoring in neonates?
Skin injury or burns.
What equipment is needed for manual blood pressure measurement?
Quality stethoscope, properly sized BP cuff, and pressure manometer.
What is the most important consideration when selecting a BP cuff?
Use the correct cuff size.
What should the patient do before the first BP reading?
Relax for at least 5 minutes.
How should the patient be positioned for BP measurement?
Sitting upright, upper arm level with the heart, feet flat on the floor.
What should be removed before BP measurement?
Excess clothing that interferes with the cuff or blood flow.
Should the patient or healthcare provider talk during BP measurement?
No.
How do you determine if a BP cuff is the correct size?
Check the arm circumference against the cuff's INDEX and RANGE markings.
Where should the BP cuff's artery marker point?
At the brachial artery.
How tightly should the BP cuff be wrapped?
Snugly around the arm.
Where is the brachial artery located for BP measurement?
At the antecubital fossa/crease of the arm.
Where should the stethoscope bell be placed?
Over the brachial artery.
How high should the BP cuff be inflated?
30-40 mmHg above normal BP; if unknown, 160-180 mmHg.
What should happen when the BP cuff is inflated enough?
Blood flow stops and pulse sounds disappear.
At what rate should BP cuff pressure be released?
About 2-3 mmHg per second.
What is the systolic BP reading?
The first rhythmic sound heard as blood begins flowing.
What is the diastolic BP reading?
The gauge reading when the rhythmic sounds stop.
How long should you wait before repeating a BP measurement?
About 5 minutes.
How can an incorrectly sized BP cuff affect systolic BP?
A cuff that is too small can increase systolic BP by 10-40 mmHg.
How can taking BP over clothing affect systolic BP?
It can change systolic BP by 10-50 mmHg.
How can not resting before BP measurement affect systolic BP?
It can change systolic BP by 10-20 mmHg.
What patient factors can increase BP?
Stress, anxiety, smoking, alcohol, caffeine, talking, and a full bladder.
How can temperature affect BP?
Cold temperatures can increase BP.
What is white coat syndrome?
An increase in BP associated with stress or anxiety during measurement.
What is capnography?
Measurement/display of CO2 throughout the respiratory cycle.
What does a capnograph display?
A waveform showing the amount of CO2 at each phase of respiration.
What shape is a normal capnography waveform?
Generally rectangular.
What else does capnography measure?
Respiratory rate.
How quickly does capnography show changes in respiratory rate and tidal volume?
Immediately.
What are two ways to measure capnography?
Nasal prongs or an inline adapter.
How are nasal prongs used for capnography?
They capture exhaled air from spontaneously breathing patients.
What else can capnography nasal prongs provide?
A small amount of supplemental oxygen.
Where can an inline capnography adapter be placed?
With a BVM and advanced airway device.
What does capnography assess?
Ventilation.
What is ventilation?
Movement of air in and out of the lungs.
What is oxygenation?
The amount of oxygen inhaled that reaches the bloodstream.
What does pulse oximetry assess?
Oxygenation.
What does pulse oximetry measure?
The amount of hemoglobin bound with oxygen.
How is SpO2 expressed?
As a percentage.
What normal SpO2 range is given in the notes?
92-96%.
What is a major benefit of capnography?
Provides real-time feedback on treatment effectiveness.
What does segment A-B represent on a capnography waveform?
Breathing in.
What does segment B-C represent?
The beginning of exhalation.
What does segment C-D represent?
Run-out of air/exhalation.
What does point D represent?
ETCO2, the end-expiratory CO2 value.
What does segment D-E represent?
Breathing in again.
What does ETCO2 mean?
End-tidal carbon dioxide.
What does ETCO2 measure?
CO2 at the end of expiration.
What are common temperature measurement sites?
Oral, rectal, and axillary.
What does axillary temperature measurement mean?
Measuring temperature at the armpit.
What is a core temperature measurement?
A measurement intended to reflect internal body temperature.
Where is an esophageal temperature probe placed?
In the esophagus.