kVp
what controls the penetration of the x-ray beam?
mAs
what factor does NOT affect beam QUALITY?
decrese kVp
what factor will cause an emission spectrum to shift to the LEFT on the x-axis (remember x-axis is quality)?
inner-shell electrons are removed and outer-shell electrons fill the vacancies
characteristic x-ray photons are produced when:
subtracting the energy the electron leaves with from its initial energy
the energy of the bremmsstrahlung photon can be determined by:
rfilament electrons interact with the positive charge of the nucleus and change direction
Bremsstrahlung x-ray photons are produced when:
filtration, kVp, target material
what factors affects beam QUALITY
half value layer (HVL)
beam QUALITY is measured by:
the range of energies of the bremsstrahlung photons
the continuous emission spectrum represents:
it produces limited photon energy levels
why is characteristic radiation production reflected as a discrete emission spectrum?
patient dose
if there is an increase in beam QUANTITY what else will increase?
mAs. kVp, filtration, distance
what factors affect beam QUANTITY?
69.5 or higher
characteristics x-rays are only at what KeV?
brems
what type of x-rays are the ones we use the most?
penetrating power of the x-ray beam
beam quality refers to:
characteristic x-ray photons
ionization of target atom electrons leads to the release of
brems photons
interactions with target nuclei produce
0.5mm
the filament electrons penetrate the face of the target approximately
braking or slowing down
Bremsstrahlung is a German word meaning
increase quantity
if you increase mA how will it effect QUANTITY?
increase quantity
if you increase kVp how will it affect QUANTITY?
decrease quantity
if you increase distance how will it affect QUANTITY?
decrease quantity
if you increase filtration how will it affect QUANTITY?
patient dose
increase in QUANTITY increases the ______ ____.
mAs because it controls the number of electrons boiled off of the filament and available to produce x-rays
what is the primary factor controlling QUANTITY?
4
if kVp is doubled, the intensity (quantity) increases by a factor of
doubling
a 15% increase in kVp is equivalent to ____ the mAs
it influences other factors such as penetrability and scatter production
why is it less desirable to use kVp to change quantity
it absorbs low-energy photons that do not contribute to the image
how does filtration affect beam quantity?
penetration
refers to those x-ray photons that are transmitted
discrete emission spectrum
Characteristic photons have what type of spectrum?
continuous emission spectrum
Brems photons have what type of spectrum?
ma, kVp, tube filtration, generator type, target material
what are the five factors that will change the appearance of the x-ray emission spectrum?
increasing kVp
what causes a shift to the right side of the curve along the x-axis?
quantity, quality
an increase in tube filtration will decrease ____ and increase ______
electrons, atoms
X-rays are produced when _____ from the cathode interact with ______ in the anode.
The spectrum increases in amplitude (more quantity). No shift to the left or right (no change in quality).
If mA increases, what happens to the emission spectrum?
Decrease in amplitude (less quantity) and the highest point of the curve will shift to the right (more quality).
If filtration is added to the tube, what happens to the emission spectrum?
amplitude increases and it shift to the right
If kVp increases, what happens to the emission spectrum?