1/44
Looks like no tags are added yet.
What are the units for radiation exposure?
Roentgen and Coulombs/kilogram
What are the units for radiation dose?
Rad and gray
What are the units for dose equivalent?
Rem and sievert
What kind of radiation does radiation exposure account for? like alphas, betas, gammas, photons, what kind?
High energy photons (x-rays, gamma rays, etc.)
Radiation produces ________ and _________ ______ _______ by ionization in air.
Electrons and positively charged ions
Radiation exposure depends on what two things?
Number of photons (intensity) and energy per photon
In exposure, the ion pairs created correspond to ?T
The number of interactions
When exposure to a large mass is uniform, exposure to any mass within the original will be _______ as that of the larger?
the same
What is absorbed dose a measure of? What does it depend on?
The energy deposited in matter. It depends on the type of matter. Also intensity and energy of the beam.
What are the units of absorbed dose?
Gray (Gy) or Rad (Radiation Absorbed Dose)
or Joules/kg
How many J/kg in a Gray?
1 each
How many rad in 1 Gray?
100 rad
What kind of radiation and matter does absorbed dose account for?
Any type of matter and any type of ionizing radiation
What does the relation between absorbed dose in air and any other medium depend on?
The mass attenuation coefficient
Maybe look over slide 14 and also definitely check statistics quiz for math.
What is the f factor?
The exposure to rad conversion factor
so it turns exposure to absorbed dose
How many rems in 1 sievert?
100 rems
Equivalent dose vs effective dose
Equivalent dose has a radiation weighting factor while effective dose has a tissue weighting factor
What are the radiation weighting factors for photons (xrays and gamma rays), beta particles, electrons, protons, neutorn, and alpha particles.
Photons, beta particles, and electrons are all 1
Protons are 2
Neutrons are 2.5-20
Alpha particles are 20
In deterministic effects, probability ________ with dose. Severity __________ of/with dose. Threshold? Example?
Probability increases with dose
Severity increases with dose
Practical threshold.
Example -- Cataracts
In stochastic effects, probability _______ with dose. Severity _________ of/with dose. Threshold? Example?
Probability increases with dose
Severity independent of dose
No threshold
Example -- Cancer and Leukemia
0.010 joules per kilogram are absorbed in a human
- Half of energy is from protons
- The other half is from photons
What is the absorbed dose and equivalent dose to the human?
Absorbed dose = 0.010 Gy (because 1 Gy = 1 J/kg)
Equivalent dose = 0.015 Sv using radiation weighting factors of 2 for protons and 1 for photons. Add each of them up to get 0.015 Sv
What is the conversion factor for Coulombs per kilogram to Roentgen?
1 C/kg = 3.88 x 10^3 R
What can an ionizationd detector directly measure and how?
Exposure by collecting all electrons produced in air. Voltage must be appropriate.

What are the six distinct regions of interest for the gas filled detectors voltage curve? What is on the x and y axes?
RIPLGC
Recombination, Ionization Chamber, Limited, Proportional, Geiger, Continuous
X axis is voltage
Y axis is current(signal)
The Ionization Region Image

Examples of ionization chamber detectors (3)
Ionization chamber, survey meter (cutie pie) which is what rad safety uses for therapy readings, radionuclide dose calibrator
What do the ionization chamber detectors operate in?
"Current mode."
Ionization chamber meters measure signal/second, which is similar to?
Exposure/second, so they measure exposure rate (mR/hour)
What does a dose calibrator measure?
Activity, or average electrons/disintegration or signal/disintegration
What is the proportional region?
The voltage at this region is high enough that electrons from the original ionization gain enough energy to ionize more gas atoms. This creates a Townsend avalanche, which amplifies the signal.
Negative ions gain sufficient energy to become ionizing radiation and produce secondary ionizations (avalanche).
What does a proportional counter require? What does it enable?
A special gas (Methane-Argon Mix)
It enables the avalanche in the proportional region
What is the common type of proportional counter?
Gas Flow -- slow flow of gas into and out of chamber
Proportional counter is low or high signal for particles? High or low energy photons?
High; Low
What is the Geiger muller region? What is this process stopped by?
Negative ions gain sufficient energy to become ionizing radiation and produce secondary, tertiary, etc. ionizations (amplification of signal.)
UV radiation produced when electrons strike positive electrode. Entire detector is ionized.
This process is stopped by "quenching."

The geiger muller detector responds as you increase its ......
VOLTAGE

Summary Table of Ionization Chamber, Proportional Counter, and Geiger Muller counter

Between ionization chamber, proportional counter, and geiger muller counter, which is an absolute assay of activity, which distinguishes types of energies and samples, and which has a large output?
In order listed
Between ionization chamber, proportional counter, and geiger muller counter, which cannot distinguishes energies and has significant dead time? Which has mean level current measurements and very small signal levels? Which is relatively insensitive to gammas?
In order: Geiger muller, ionization chamber, and proportional counter
In general, ionization detector can or cannot measure the energy of a single photon?
Cannot
What can film be used for and how?
Can be used to measure absorbed dose by carefully calibrating the film so that film density is related to absorbed dose. Dose measurements can then be performed using a densitometer
Which dosimeter type is an inorganic scintillator that absorbs energy and holds it until heated, releasing the energy in the form of visible light which can be measured by a PMT?
Thermoluminescent dosimeters, which calibration of this readout ields a direct measure of absorbed dose.

What is the common material found in TLDs and what type of dosimeter (badge or ring)?
Common material is Lithium Fluoride
Commonly used in ring badges
Which dosimeter type is energy stored as excited atoms in aluminum oxide matrix, with atoms stimulated with green light, and then a red light being emitted and measured?
Optically Stimulated Luminescence Dosimeters
What is the material of OSL dosimeters?
Aluminum Oxide