what two types of xrays are responsible for the radiographic image
those that pass through the patient without interaction and those that are compton scattered within the patient and come out of patient
image forming xrays
these are x rays that exit the patient(also called remnant xrays) and interact with the ir
off focus radiation
happens when projectile estray and interact at positions on the anode other than the focal spot, they also increase image blur
what is the primary effect of collimation
it reduces patient radiation dose by restricting the volume of tissue irradiated and it improves image contrast
as scatter radiation increases
the rad image loses contrast and becomes more gray and dull
whats special about the variable-aperture collimation
its the most commonly used beam restricting device in radiography
first stage entrance collimation
it controlls off focus radiation, its made of PB(lead), and the shutter blades protrude from the top of the collimator into the x ray tube
second stage collimation
its made of PB(lead), 3 mm thick and has long and cross blades
what are light localizing collimators
positive beam limiting devices that automatically size the collimated beam to size of the ir
characteristics of a positive beam limiting device
they have small lamp and mirror, their projected light field coincides with the x ray beam, and under no circumstances do their light fields exceed the size of the image receptor
scatter radiation
every radiographic procedure apart from mammography, produce scatter radiation if there is interaction of photons with soft tissue
what causes fog
the detection of scattered photons, it also does not add info to the content in the image
what percentage of xrays incident on the patient reach the ir
1%
what 3 factors contribute to increased scatter radiation
increased kvp, increased field size, increased patient thickness
what are the 3 types of beam restricting devices
aperture diaphragm, cones or cylinders, collimators
more scatter is produced for
thick body parts, high kv levels, and large collimated areas
grids ____ have anything to do with the production of scatter radiation
do not
scatter clean up
use of grid, and air gap technique
when using a grid or air gap technique what happens to patient dose
the radiation dose increases
grids are used ____ scatter has been produced
after
as kv increases, compton interactions_____, and photoelectric effect ____
increases, decreases
what is the techs dose
compton scatter
what is the patients dose
Photoelectric(PE)
when the kvp goes up what happens
patient dose goes down, more scatter is produced, and reduced contrast
whats the percentage of xrays that reach the image receptor
1%
brems and k- characteristics are interactions between
electrons and the anode target when x rays are produced
classical, photoelectric, and compton scatter are interactions between
xrays and matter(body)
interactions between electrons and the anode create what type of radiation
bremsstrahlung and k-characteristic radiation
what makes or breaks the type of interaction
kv level
the curve on the xray emmision graph represents what
brems
what represents the spike
characteristic
what causes brem specifically
incident electrons deflecting with resulting energy loss and when electrons approach a nuclear charge and causes change in direction and loss of energy, essentially causing the first stated thing
what causes characteristic radiation specifically
incident electrons ejecting an inner shell tungsten electron, an orbital electron moving to fill in the space of an inner shell, or transitions of electrons from outer to inner shells
the two major interactions that occur when xrays strike the body that are categorized as ionization events are
photoelectric effect and compton scattering
photoelectric effects are responsible for what
contrast and the total amount of incident radiation absorbed
compton scattering is responsible for what
scatter radiation and incident radiation being partially absorbed
a third form of interaction is called classical and its a
excitation event that only occurs 5% of the time but does NOT cause ionization
PIICT- P meaning
Photoelectric
PIICT- I meaning
inner shell electron interaction with an x ray photon
PIICT- I meaning
ionization event
PIICT- C meaning
contrast
PIICT-T meaning
totally absorbed
As PE goes up, KV goes__, and Z# goes ___
down, up
CLOIPS- C
compton
CLOIPS-L
loosely bound electron
CLOIPS-O
outer shell electron
CLOIPS-I
ionization event
CLOIPS-P
partial absorption of incident photon
CLOIPS-S
scatter producer
what does bremsstrahlung mean
breaking radiation/slowing
What is Bremsstrahlung radiation?
incident electrons that are deflected with energy loss
when the xray beam field size is increased what happens to scatter
it increases
patient does goes down what happens to spatial resolution
goes up
what is the most common light localizing device
variable- aperture collimator
as the fov goes down, what happens to scatter
goes down
when collimation goes up
scatter goes down
are there any circumstances where the xray beam should exceed the size of the ir
no
cylindar cones
they are metal cylinders that attach to the bottom of the collimator and are used to tightly restrict the beam to a small circle
when making a large collimation field small
you need to increase mass
when making a small field large you need to decrease mass
when going from 14x17 to 10x12
increase mass 20%
when going to 8x10
increase mass 30%
when going to 5x7
increase mass 50 percent
what is the aperture diaphram
its a flat piece of lead with a circle or square opening in the middle that is placed really close to the xray tube window, and it has no moving parts
how does the grid(antiscatter grid) work
it is placed between the patient and ir and uses geometry to reduce the amount of scatter radiation that would reach the ir
when using a grid what happens to techniques
techniques need to go up which inturn increases patient dose
are grids radiation protection devices
no
what are grids for
they are devices that improve radiographic film quality by increasing contrast
when should a grid be used
when patient body part thickness is greater then 10cm or when kvp is above 60
what is a antiscatter grid
its essentially a regular grid that uses a series of slits that separate highly attenuated septa which are made of lead, in order to absorb scatter from primary x rays
what is a grid ratio
its the ratio of the height to width of the interspaces in the grid
what are the 3 grid designs
parallel, crossed, and focused
what are parallel grid designs
they are the simplest type of grid, essentially all the lead strips are parallel
what are crossed grid designs
they are parallel grid designs that run across each other and they clean up better then parallel
what are focused grid designs
they are essentally parallel grid strips that angle towards the center
focal length
determines the amount of slant of the slits in the grid
grid frequency
refers to the number of gird bars per unit length.
what is the bucky factor
it is the ratio of the entrance exposure to the patient when the grid is used to the entrance exposure without the grid
what is the formula for the bucky factor
B=patient dose with grid over patient dose without grid
what happens when the contrast improvement factor goes up
grid ratio goes up
what is the greek symbol for selectivity
its sigma(sideways m)
what is sigma primarily influenced by
the total lead content in the grid
what is grid cutoff
the undesirable absorption of primary xrays
its the _____ disadvantage of parallel and crossed grids
main
linear 5:1 and 6:1 grids have a
very wide positioning latitude
linear 16:1 have
narrow positioning latitudes
when patient dose goes up
grid ratios go up
high grid ratios are usually used for
high kvp examinations
patient dose at high kvp is
less than that of low kvp
air gap technique is an alternative to
using a grid
for every additional cm of air gap increase mas by
10%
at 10-15 cm, we see a visible change in
oid
the main disadvantage of using an air gap technique is
the possible image magnification with focal spot blue
what is air gap technique most commonly used for
chest radiography and cerebral angiography
when was the virtual grid introduced
fuji in 2014
what is a virtual grid
digitally reconstructed radiography
how does it work
computer algorithms take out most of the scatter produced
what happens when you use a virtual grid
reduces patient dose, improves image contrast, and its easier to use than grids
as patient thickness goes up
compton scatter goes up
what improves spatial and contrast resolutions while also lowering patient dose
compressing anatomy