CRCST Exam Test Prep 150 Questions

0.0(0)
Studied by 1 person
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/149

encourage image

There's no tags or description

Looks like no tags are added yet.

150 Terms

1
New cards

Which agency provides standards for the Installation of Sprinkler Systems in Central Service department?

NFPA (National Fire Protection Association)

2
New cards

K-wire is used for which of the following procedures?

Orthopedic

3
New cards

Which of the following is considered a critical device?

Retractors

4
New cards

The final phase of Ethylene oxide sterilization cycle is:

Aeration

5
New cards

Which of the following steam sterilization method uses series of vacuum and pressure pulse to remove air?

Prevacuum

6
New cards

Which specialty deals with synovial fluid?

Orthopedics

7
New cards

Automated cleaning equipment that uses sound waves to create bubbles that implode when they come in contact with instruments to dislodge soil from the instruments?

Ultrasonic cleaners

8
New cards

Which organization works to reduce burden of biohazards?

OSHA

9
New cards

Which of the following names is associated with self-retaining retractor?

Gelpi

10
New cards

Vital organs are protected by…

Skeletal System

11
New cards

The purpose of instrument count sheets is to provide

Detailed list of tray contents

12
New cards

Sterile technicians must assemble instrument trays by

Identifying and verifying instruments against count sheet

13
New cards

Which of the following is not considered an ergonomic stressor?

Job rotations

14
New cards

Ergonomic injuries:

are a risk factor for persons who perform repetitive or physical work

15
New cards

Workplace conditions that pose risk of injury to the musculoskeletal system of the worker is known as

Ergonomic Hazards

16
New cards

Which of the following is a system used to treat the final rinse water used for cleaning?

Deionization

17
New cards

Which water purification system uses semi-permeable membrane to remove organic materials from the water?

Reverse osmosis

18
New cards

Why is it important to label each package with a load control number?

The load control number helps to trace processed items to a load in which it was sterilized

19
New cards

Which of the following pieces of information cannot be found on the load control number label?

requesting physician

20
New cards

All of the following information should be included on a load log sheet except

Position of packages in the sterilizer

21
New cards

According to Spaulding classification which of the following classified as critical?

needles

22
New cards

What is the Spaulding classification for endoscope?

Semi-critical

23
New cards

An inventory system that keeps track of all the incoming and outgoing supplies so that quantities of supplies in storage are known at all times

Perpetual Inventory System

24
New cards

An inventory system where items are owned by the vendor but stored at the health care Facility

Consignment

25
New cards

The inventory system where enclosed cart is prepared to manage instruments and supplies for individual surgical procedures

Case Cart

26
New cards

The microorganism of choice for hydrogen peroxide gas plasma is:

Geobacillus Stearothermophilus

27
New cards

The final phase of hydrogen peroxide gas plasma sterilization is

Vent

28
New cards

Which of the following items can be sterilized in hydrogen peroxide gas plasms?

Batteries

29
New cards

What is the function of lighting in the sterile storage area?

It prevents forgotten inventory

30
New cards

What is the next step of the processing cycle after items are cleaned?

Inspect

31
New cards

Which organization provides guidelines for Cleaning and Care of Surgical Instruments?

AORN (The Association of PeriOperative Registered Nurses)

32
New cards

Which of the following is an example of self-retaining retractor?

Weitlaner

33
New cards

Which of the following will occur if Ultrasonic bath temperature is too high?

it will lead to protein coagulation

34
New cards

Which agency requires use of personal protective equipment in the decontamination area?

OSHA

35
New cards

What is the term used for an informal communication network at work?

Grapevine

36
New cards

Which of the following is a formal communication?

Email from the department

37
New cards

What is bioburden?

The number of microorganisms contaminating an object

38
New cards

All these factors that impact the effectiveness of sterilization EXCEPT

Instructions in Manufacturer's IFU

39
New cards

TAH is the medical abbreviation that relates to which of the following surgical procedures?

Hysterectomy

40
New cards

Which of the following package wrapping methods creates a package within a package?

Sequential

41
New cards

The higher the bioburden of an object

the more difficult it will be to sterilize it

42
New cards

Ultrasonic cleaners clean by a process called:

Cavitation

43
New cards

Which of the following is removed with Descalers?

Chalky White Substance

44
New cards

The ideal level of chloride in tap water should be

100 PPM

45
New cards

The humidity in the sterilization equipment room should be between

30%-60%

46
New cards

What is the reason for tamper-evident lock on a rigid container?

It indicates the container has not been opened or tampered with

47
New cards

Bowie dick tests should be run in:

dynamic air removal steam sterilizers

48
New cards

Where should Bowie-dick test pack be placed in the sterilization chamber?

Above the drain on the bottom rack

49
New cards

What is the sterilizer setting for Bowie-Dick test?

3 1/2 to 4 minutes exposure at 270-273 degrees F

50
New cards

Which of the following body systems is related to arthro?

Skeletal

51
New cards

The purpose of instrument stringer is

For keeping hinged instruments in open positions

52
New cards

Safety Data Sheets are provided by

Product manufacturer

53
New cards

The "pass" reading of a CI means:

The parameters for sterilization have been met

54
New cards

What type of blades do scissors with black rings have?

microgrind/supercut blades

55
New cards

This body system controls growth and maintains body functions and chemical messengers

Endocrine System

56
New cards

Which of these materials is used to test for the sharpness of Rongeur?

Index Card

57
New cards

Which of the following is used to test the sharpness of Osteotomes?

Plastic dowel rod

58
New cards

What is used to test the sharpness of scissors longer than 4 1/2 inches?

Red test material

59
New cards

Which of the following scissors is designed to have the sharpest cutting edge?

Black-Handled

60
New cards

Scissors with tungsten carbide cutting edges are usually identified by

Gold Handles

61
New cards

How many times should instrument marking tape be wrapped around the instrument?

1 to 1 1/2

62
New cards

A Chemical process applied during the instrument manufacturing process that provides corrosion-resistant finish on instruments is

Passivation

63
New cards

The part of a ring-handled surgical instruments that locks the handles in place

Ratchet

64
New cards

Which of the following is the correct sequence for removing Personal Protective Equipment (PPE)?

Shoe covers

65
New cards

Wicking material are used to:

Allow air removal

66
New cards

Bacteria that are often pathogenic to humans because they grow well at body temperature

Mesophile

67
New cards

Which of the following is used for time tracking of patient care equipment?

RFID

68
New cards

Which class of indicators is Bowie Dick Test?

It is a Chemical Indicator

69
New cards

Which of the following is a high-level disinfectant approved for disinfecting flexible endoscopes?

Ortho-phthalaldehyde

70
New cards

When should the operator review the physical monitors of the sterilizer?

During and at the end of sterilization cycle

71
New cards

Who must ensure and verify that devices requiring sterilization have been validated for use in the sterilizers available at a specific facility?

User friendly personnel

72
New cards

How frequently should temperature and humidity levels in the sterile storage area be recorded?

Daily

73
New cards

Equipment validation is performed by the

Device manufacturer

74
New cards

Which of the following will be used for routine sterilizer efficacy monitoring?

BI PCD

75
New cards

Which of the following protocols of PCD is INCORRECT?

The PCD should be a commercially prepared

76
New cards

Sterile loads containing implants must be monitored with:

Biological Indicator

77
New cards

Which of the following packaging material is compatible with hydrogen peroxide gas plasma sterilization?

Tyvek

78
New cards

What class of medical devices are sterilizers?

Class 2

79
New cards

At the completion of the test cycle

Bowie Dick test pack showed a uniform color. What does it mean?

80
New cards

At what temperature and exposure time should Bowie Dick test pack be run in the sterilizer?

273 degrees for 3.5 to 4.0 minutes

81
New cards

Event-related sterility depends on all of the following EXCEPT:

Expiration Date

82
New cards

All of the following indicators can be used to verify sterility assurance of processed instruments EXCEPT:

Magnetic

83
New cards

What is the recommended frequency for routine testing with a biological indicator PCD for steam sterilization?

Weekly

84
New cards

To achieve the highest level of assurance

monitor every load with:

85
New cards

If a biological test is performed daily

how often should a control BI be incubated?

86
New cards

Which of the following events will trigger a recall after a processed medical device is released?

If a positive BI PCD result was obtained

87
New cards

What is the most common reason for steam sterilization failure?

Lack of steam contact with the instrument

88
New cards

Load containing implants should not be released until

The BI result is known to be negative

89
New cards

Which of the following is used to stabilize a fractured finger?

K-Wires

90
New cards

Which endoscope would be dispensed for a procedure that requires visualization of the lower part of the large intestine?

Sigmoidoscope

91
New cards

Virus-like protein containing element that lacks DNA and RNA?

Prions

92
New cards

What is the meaning of an item being sterile?

Absence of all living organisms

93
New cards

Medical device reporting is regulated by:

FDA

94
New cards

Enzymes used to breakdown and remove heavy soil on instruments?

Protease Enzymes

95
New cards

AAMI is the association that sets standards for:

Instruments

96
New cards

Behavior relating to what is good or bad relative to the standards of conduct for one's profession

Ethical behavior

97
New cards

When are sterile packs most vulnerable to contamination?

Immediately after sterilization

98
New cards

Poor posture is an example of which type of hazard?

Ergonomic

99
New cards

A dating system that records the date of the year as the number of days that have elapsed since January 1st

Julian Date

100
New cards

Heat transfer process used to heat items in steam sterilization is known as:

Convection