what are the 2 types of floor structure?
solid/ ground bearing
suspended
what material is the base of solid/ground bearing floors?
concrete
what materials can form the main structure of suspended floors?
concrete
timber
steel
how are solid and suspended floors different in regards to how they distribute loading?
solid: act independently of the rest of the building, transfer load directly to the natural foundation
suspended: tied to walls and foundation, transfer loading through them
functional requirements of a ground floor
strength and stability - resist soil heave
damp resistance - resist capillary action, doesn’t need to be impenetrable
thermal insulation
prevention of growth of vegetable matter within building
support wearing surface
protect from gases emitted by the soil
how much topsoil must be removed during preparation stage?
150-230mm
why is topsoil removed during pre-ground floor construction?
top soil is too soft and easily compressed → uneven settlement
poor loadbearing capacity - dig deeper to better soil, ensures even settlement
what is the key building regulations stipulation for the DPC at the wall?
must be positioned at least 150mm above finished ground level
where is a DPC and DPM found? what must be ensured in every structure?
DPC - wall
DPM - floor
must ensure a continuous run, enclosing building completely to prevent water penetration
key stages of pre-ground floor construction
removal of top soil
wall is raised to DPC level and DPC installed?
service pipes & ducts are placed → check for defects throughout, both quality and connection
drains must be tested for water tightness
install hardcore
what is hardcore? what is preferred?
a graded aggregate - limestone is best, chalk is close second
distributed across earth and compacted to provide base for flooring
prefer to use finer aggregate - improves compaction achieved
how does hardcore improve the strength and stability of a structure?
prevents contamination of wet concrete by soil
consistent material under entire floor area → evenly distributes loading
consistent water content and material beneath concrete → improves even set
raises floor level as required without excess concrete
limits influence of soft ground
eliminates passage of moisture from the ground
key characteristics of hardcore
cheap
durable
chemically inert
not affected by water
where do the best hardcores come from?
by products of the aggregate industry
gravel/ stone aggregate
quarry waste
chalk
limestone
what issues can be found in recycling materials as hardcore?
contain chemicals which react poorly w/ concrete, causing shrinkage and cracking
brick rubble → sulfates from gypsum plaster
concrete rubble → too large
ash from furnaces → sulfates
blast furnace slag → sulfates
how can issues from recycling waste as hardcore be solved?
use additional layers to prevent contamination of concrete
blinding atop hardcore
DPM sitting below concrete slab
thoroughly clean and break down aggregate to appropriate size
how should hardcore be laid?
if overall thickness > 200mm - lay in layers 150mm thick
must be well compacted
if hardcore thickness > 500-600mm → consider suspended floor
how should you finish hardcore for solid and suspended ground floors?
solid: blind w/ layer of sand 25mm thick if floor is reinforced
suspended: cover with layer of concrete 100mm thick
minimum and typical thicknesses of insitu concrete slabs in solid ground floors
minimum: 100mm
typical: 150mm
where can you not use a ground bearing concrete slab
in presence of
Clay subsoils
High water tables
increases risk of chemical attack, esp if slab is wet for extended periods
cannot use traditional DPMs - can’t fight direct water pressure
deep hardcore
where and how do you reinforce a concrete slab?
use steel mesh - adds tension to concrete as it dries, less likely to shift & crack over time and resist pressure from soil
must be layer of sand blinding beneath slab if reinforcement is used
2 main methods of finishing insitu concrete
tamping
powerfloating
what does tamping wet concrete do?
levels concrete
removes surplus air and water
what does power-floating dry concrete do?
provides smooth finish
protects w/ layer of sand until construction work is complete
can apply flooring directly on top
name 3 main types of DPM
sheets of polythene - over or under slab
cold applied bitumen solution - painted on top of slab
hot asphalt - applied to top of slab
what does the DPM do?
provide barrier against rising damp but NOT direct water pressure
minimum DPM thickness
0.3mm
most popular DPM in modern day
polythene
advantages of placing DPM below slab
DPM protected throughout construction and lifetime by slab
how must concrete be protected in extremely hot and cold weather as it dries?
hot: cover with polythene sheet on top, prevents excessive evaporation
cold: cover with hessian or sand, prevents freezing
draw 4 potential variations of thermal insulation and DPM in floor slab


describe the construction of this solid floor
DPM is above insulation
insulation is beneath concrete slab - common practice - must be impervious to water
insulation and DPM both upstand against wall

describe this solid floor? when might it be used?
insulation is below slab but above DPM
insulation material does not have closed cells e.g. expanded polystyrene
common is toxic gases are present

describe this solid floor construction
insulation is above slab - cold slab construction
thicker screed - 65 to 75mm
thin slip layer should be placed between insulation and screed e.g. vapour membrane?
will heat quicker - more heat retained in building interior

describe this solid floor construction? how is it different to the others?
insulation placed over concrete slab
DPM beneath slab
additional vapour check between chipboard and insulation
finished with absorbent chip board
how are solid concrete floors finished? thickness and mix?
SCREED!
provides level surface for tiles
38mm thickness minimum
65-75mm thick if spread over insulation
1:4 cement:sand
must dry out completely before final finish
what is a floating floor?
dry finish to solid concrete floor
tongues and grooved chipboard
no delays - no drying time
laid over 50mm insulation board
require vapour control underneath if DPM is beneath slab
advantages of solid floor construction
fire won’t creep beneath floors

disadvantages of solid floor construction
floor has massive surface area - edges and base
incompatible w/ brownfields sites

when is a suspended ground floor commonly used?
soil heave is likely
hardcore > 500-600mm - spenny & can’t compress evenly
above aggressive soils
poor bearing ground
high water table - provides direct pressure, DPMs vulnerable
steep/difficult slopes
2 main suspended floor types in houses
precast concrete - modern
timber - traditional
how are timber ground floors supported?
sleeper walls - engineering bricks in honeycomb formation
wall plates atop sleeper walls → uniform loading
purpose of honeycomb sleeper walls
long lengths of timber are expensive - can use shorter members
allows cross-ventilation to actual vents in flooring
height of the underfloor space above the surface of the concrete must be at least…
75mm to underside of any timber wall plate
150mm to underside of suspended timbers
how can cross ventilation be provided beneath a suspended floor?
air brick or sleeved vents in all external walls
sleeper walls
min 1500mm2 per m run of wall
diagram of cross section of suspended floor

how are suspended floors thermally insulated
boards inserted between timber joists
quilts draped over timber joists
boards placed on pre-cast concrete floors

approx span of inverted t beams in pre-cast concrete suspended floors
6m
what dont you need in a concrete suspended floor? what might you need instead and when?
might not need a DPC
DPM may be needed if soil emits toxic gases
draw concrete suspended floor design

strength of concrete infill blocks in pre-cast floor
7 N/mm2
ratio of cement: sand in floor grouting
1:4
why do you grout a pre-cast concrete floor?
tighten floor
spread loads
barrier for draughts and vermin
ensures airtightness
how are pre-cast concrete floors finished
lightly reinforced (with mesh rather than rebar) concrete topping
powerfloat it to provide smooth enough finish for carpets
could also use screed or dry floating floor
besides concrete blocks, how else can the gaps between concrete beams be filled?
polystyrene
advantages of beam and polystyrene floors
avoid cold bridging by insulating bottom of the beam
why are air bricks required in suspended floors?
ventilate stale air
ventilate gas that may collect beneath the floor if there’s a gas leak
advantages of suspended floor construction

disadvantages of suspended floor construction