define separating/party walls

walls that divide on house from another i.e. in terraced dwellings

2
New cards

define compartment walls

walls that divide a building into fire resisting compartments to restrict the spread of fire.

any separating wall must also be constructed as a compartment wall

3
New cards

define buttressing walls

walls that are built at right angles to another internal/external wall to provide structural restraint

4
New cards

define partition walls

walls that sub-divide the space enclose by external walls of a building

5
New cards

functions of walls

  • physical separation of space - enclose/divide

  • strength and stability - support upper floors & roof


6
New cards

general rule of determining if a wall is (non)loadbearing

1B thick → loadbearing

1/2B thick → non-loadbearing

7
New cards

general rule of thickness to height ratio of loadbearing walls

thickness >= 1/16th height

8
New cards

which section of building regulations covers minimum thickness, height and length of a wall?

approved document A section 2c10

9
New cards

minimum thickness of walls at a specified heigh and length

minimum thickness 90mm: height & length ≤ 9m

minimum thickness 140mm: height and length12m≥T>9m

10
New cards

if weight of external wall (sum of both leaves) is less than 120kg/m2, openings on each floor should be….

no less than 1m high and not more than 700mm from the face of sound resisting wall

11
New cards

building regulations on fire resistance

  • minimum 30mins fire resistance in dwellings

  • material must have low combustibility

  • separating walls MUST be constructed as compartment walls

  • separating walls must run FULL HEIGHT of the building


12
New cards

what section of the building regs is the sound insulation of separating walls included?

document e section 2

13
New cards

what are the main considerations of the building regs for separating walls?

sound insulation and fire resistance

14
New cards

why do the building regulations for solid masonry separating walls stipulate an overall minimum mass per area of wall?

mass is good at insulating airborne sound between properties connected by separating wall

15
New cards

minimum mass per unit area of solid brick wall w/ plaster/plasterboard on both sides

375kg/m2

16
New cards

minimum mass per unit area of solid concrete block wall w/ plaster/plasterboard on both sides

415kg/m2

17
New cards

minimum mass per unit area of dense concrete block cavity wall w/ plaster/plasterboard on both sides and a minimum cavity of 50mm

375kg/m2

18
New cards

minimum mass per unit area of lightweight aggregate concrete block with a minimum cavity of 75mm

plaster to both room faces - 300 kg/m2

plasterboard to both room faces - 275 kg/m2

19
New cards

purpose of partition walls

internal walls which divide interior of building into areas of accommodation and circulation

20