Perfix

Metallic orthopedic implant; Screw used for ACL reconstruction that is screwed firmly into bone; Safe; Ferromagnetic; But not in danger of dislodgement because of the way it is implanted

2
New cards

Revo Surescan

Cardiac pacemaker; Treat bradycardia with low energy electrical impulses and monitor heart rhythm; Conditional; 1st FDA approved MR conditional cardiac pacemaker; Most pacemakers are strictly contraindicated for standard MRIs (several patients have died); Must be put in asynchronous mode for MRI

3
New cards

Advantio, advisa, ensure, enrhythm, ingenio, promri

Cardiac pacemaker; Treat bradycardia with low energy electrical impulses and monitor heart rhythm; Conditional

4
New cards

Kora

Cardiac pacemaker; Treat bradycardia ith low energy electrical impulses and monitor heart rhythm; Conditional; Detects magnetic field and automatically switches to asynchronous pacing

5
New cards

Evera surescan

Defibrillator; Provide defibrillation therapy for tachycardia when needed; Conditional

6
New cards

Activa

Deep brain neurostimulator (DBS); Treats Parkinson's disease, tremor, dystonia; Conditional

7
New cards

RestoreSensor Surescan

Spinal cord neurostimulator (SCS); Treats chronic, intractable (severe) pain of neurological origin; Conditional

8
New cards

Argus II

"Second sight" retinal prosthesis neurostimulator; Electrical stimulation of retina to induce visual perception in blind patients; Conditional:; 3T or less; External equipment (VPU and glasses) is unsafe

9
New cards

Enterra

GES neurostimulator; Treats chronic, intractable nausea from gastroparesis; Unsafe

10
New cards

Interstim

Sacral nerve neurostimulator; Treats urinary incontinence or bowel control; Conditional

11
New cards

Actiflo

Indwelling bowel catheter system; "Zassi bowel management system"; Conditional:; 3T field and 720 G/cm gradient or less

12
New cards

Cyberonics

Vagus nerve neurostimulator; Treats epilepsy, depression, anxiety, alzheimer's, morbid obesity, migranes; Conditional

13
New cards

Bone/spinal fusion stimulator (SpF)

Spinal nerve stimulator; Adjunct therapy for spinal fusion procedures; Conditional

14
New cards

Accurx constant flow implantable pump

Drug pump; Continuous medication storage and dispenser; Conditional; Made of a titanium shell and diaphragm

15
New cards

DuraCath

Drug pump; Long term intraspinal (epidural or intrathecal) medication; dispenser; Conditional; Mad of silicone and steel

16
New cards

Actipatch

Pain reduction compression sleeve; Drug free compression sleeve that accelerates healing of soft tissue injuries with EM frequency therapy; Unsafe; Battery operated microchip and EM frequency can cause burns

17
New cards

Alsius coolgard 3000

Intravascular temperature management; Cools blood; Unsafe; Catheters must be disconnected

18
New cards

Martenistic stainless steel aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Unsafe; Ferromagnetic stainless steel; Martenistic =; never safe

19
New cards

Vari-angle aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Unsafe; 1 reported aneurysm clip fatality

20
New cards

Yasargil aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Conditional:; 1.5T or less

21
New cards

Austenitic stainless steel aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Conditional:; 1.5T or less; Austenitic = ok

22
New cards

Phynox aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Conditional:; 1.5T or less

23
New cards

Elgiloy aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Conditional:; 1.5T or less

24
New cards

Titanium alloy aneurysm clip

Aneurysm clip; Manage intracranial aneurysms and arteriovenous malformations (AVMs); Conditional:; 1.5T or less; Gives smallest artifact out of all types of aneurysm clips

25
New cards

Baha

Bone conduction implant; Hearing aid that works via bone (skull and jaw) conduction instead of outer/middle ear; Conditional; Outer sound processor must be removed but implant itself is conditional; Uses bone conduction rather than sound waves

26
New cards

Bravo

Gastric monitoring system; PH monitoring system of gastric reflux inserted endoscopically; Unsafe; No MRIs within 30 days of procedure

27
New cards

Breast tissue expanders

Tissue expander; Used for breast reconstruction, deformity corrections, cosmetic reasons; Generally unsafe; Some expanders have magnetic ports that are significantly attracted to MR field, produce large artifacts, and can injure patients

28
New cards

Breast implants

Breast implant; Typically silicone or saline; Safe

29
New cards

Cardiovascular catheter

Catheter; Used to measure cardiac pressure, output, saturation, etc; Conditional or unsafe (when made with conducting material); Used in iMRI

30
New cards

Poppen Blaylock carotid artery vascular clamp

Vascular clamp; Unsafe; Only contraindicated carotid clamp because of ferromagnetism; All other carotid clamps are conditional

31
New cards

Celsius control system (innercool)

Temperature control system; Catheter, console, and disposables; Conditional; "Head only" scanning; MRIs on all other body parts is unsafe

32
New cards

Codman Hakim programmable valve

Cerebrospinal fluid (CSF) shunt valve; Treat hydrocephalus by bypassing fluid; Conditional; Valve pressure can be changed by magnetic field

33
New cards

Polaris adjustable pressure valve

Cerebrospinal fluid (CSF) shunt valve; Treat hydrocephalus by bypassing fluid; Conditional; Despite magnetic components, it can be scanned at 3T or less

34
New cards

Delta shunt assembly, pulsar valve, Sophy mini monopressure valve

Cerebrospinal fluid (CSF) shunt valve; Treat hydrocephalus by bypassing fluid; Conditional

35
New cards

Cochlear implants

Hearing implant; Electrically activated device for hearing; Conditional at very low fields or unsafe

36
New cards

Codman microcsensor

Intracranial pressure (ICP) monitor; Monitors ICP; Conditional

37
New cards

Coils

Cardiac implant; Stainless steel implant that slows blood flow; Conditional: wait 6 weeks after implantation for device to be secure in vessel wall if it contains ferromagnetic material; 1.5T

38
New cards

Gianturco (Cook) stent

Cardiac implant; Stainless steel implant that prevents vessel closure; Conditional: wait 6 weeks after implantation for device to be secure in vessel wall if it contains ferromagnetic material; 1.5T

39
New cards

Coronary artery stent

Cardiac implant; Implant that prevents vessel closure; Conditional:; SAR 2W/kg; 3T or less; 15min max per pulse sequence; There are no ferromagnetic coronary stents so patients can undergo MRIs immediately after placement

40
New cards

Greenfield filter

IVC filter; Traps blood clots, prevents pulmonary embolism; Conditional: wait 6 weeks after implantation for device to be secure in vessel wall if it contains ferromagnetic material; 1.5T

41
New cards

Cozmo pump

Insulin pump; Manages diabetes through insulin infusion; Conditional; Must be removed before MRI

42
New cards

Craniofix

Bone flap fixation device; Secures bone flaps after craniotomy; Conditional:; 1.5T or less

43
New cards

Copper T, Mirena, Etonogestriel

IUDs; Contraceptive; Conditional:; 1.5T; Copper creates only small artifacts

44
New cards

Aquacel Ag, Nyenhuis, Duan, Mepilex Ag

Silver containing wound dressings; Antimicrobial dressing containing silver; Safe

45
New cards

Ambit

Epidural pump; Infuse pain management drugs; Not recommended to be scanned but not tested much

46
New cards

Essure

Contraceptive; Metal implant for birth control near fallopian tube; Safe

47
New cards

Esteem

Hearing aid; Sound processor with sensor and drivers, replicates ossicular chain; Conditional

48
New cards

Hoffmann II, TenXor

External fixation device; Orthopedic device; Conditional; Heating is the primary concern

49
New cards

Fiber optic pacing leads

Pacemaker leads; Temporary pacing; Conditional:; SAR 1.5W/kg

50
New cards

Foley catheter with temperature sensor

Urinary catheter; Sense temperature of urine; Conditional:; Temp sensor removed; Temperature sensor must be disconnected for MRI

51
New cards

Freehand system

Functional neurostimulator (FNS); Neuroprosthesis that stimulates peripheral nerves for hand grasping; Conditional:; 1.5T only

52
New cards

Nonmetallic shunt tubes

Glaucoma drainage shunt tube; Creates drainage pathway to control intraocular pressure for glaucoma patients, made with nonmetallic materials; Safe

53
New cards

Optonol LTD

Glaucoma drainage shunt tube; Creates drainage pathway to control intraocular pressure for glaucoma patients, made with stainless steel; Unsafe

54
New cards

Halo vest

Cervical fixation device; Used to immobilize neck after injury; Conditional; Potential induced current (Faraday's law) in ring and eddy currents which could lead to burns

55
New cards

Hearing aid

Hearing aid; Used to enhance hearing; Must remove prior to entering MR room; Magnetic fields can damage device

56
New cards

Annuloplasty ring

Heart valve prostheses; Reinforces shape of heart valve so it can open and close properly; Conditional; Minimal magnetic attraction at 3T

57
New cards

Hemostatic vascular clips

Vascular clip; Stops bleeding; Conditional:; 1.5T; Made of nonferromagnetic steel and tantalum; Nonmagnetic clips can be scanned immediately after placement

58
New cards

Insound XT lyric hearing device

Hearing device; Aids in hearing; Conditional; Must be removed prior to MRI

59
New cards

Isomed constant flow

Infusion pump; Medication administration; Conditional:; 1.5T; Image distortion only directly around site of implant, worsens with GRE, reduced with SE; Potential PNS

60
New cards

Licox

Oxygen monitoring and temperature probe system; Monitors oxygen and temperature; Conditional

61
New cards

Magec

Magnetic growing rods; For early onset scoliosis (EOS) with an external remote controller (ERC); Conditional

62
New cards

Medivance

Nasogastric sump tube with temperature sensor; Conditional:; 3T or less; 720 G/cm gradient or less; Max of 3W/kg SAR

63
New cards

Medstream

Programmable infusion system; Medication administration; Conditional

64
New cards

Medtronic minimed

Insulin pump; Medication administration; Must be removed prior to MRI

65
New cards

Barostim neo

Neuromodulator; Treats heart failure; Unsafe or conditional; IPG model 2101: unsafe; Lead models: unsafe; IPG model 2102: conditional at 1.5T

66
New cards

Endostim LES

Lower esophagus stimulation (LES) neurostimulator; Stimulates dysfunctional LES muscle; Highly specific conditional

67
New cards

Pulsante SPG (sphenopalatine ganglion)

Neurostimulator; Treats cluster headaches; Conditional

68
New cards

Senza SCS

Spinal cord stimulator; Manages pain; Conditional

69
New cards

RNS neuropace

Neurostimulator; Treats refractory partial epilepsy; Unsafe; RNS stimulator and leads are both unsafe

70
New cards

Stimwave

Spinal cord and peripheral nerve stimulators; Treats pain; Conditional

71
New cards

Stimrouter

Neurostimulator; Treats pain of peripheral origin; Conditional

72
New cards

Neurocybernetic prosthesis (NCP)

Vagus nerve stimulator; Treats pain, epilepsy, depression, etc; Conditional

73
New cards

Fatio eyelid spring

Occular clip; Treats scleral buckling; Unsafe

74
New cards

Retinal tack

Occular clip; Treats scleral buckling; Unsafe

75
New cards

Troutman magnetic occular implant

Occular clip; Treats scleral buckling; Unsafe

76
New cards

Non-magnetic occular clips

Occular clip; Treats scleral buckling; Safe

77
New cards

McGee stapedectomy piston prosthesis

Otologic implant; Aids in hearing; Unsafe; Made of ferromagnetic platinum and stainless steel alloy; Recalled by manufacturer

78
New cards

Tuebingen type ventilton tubes with wire

Otologic implant; Aids in hearing; Unsafe

79
New cards

Minmal type ventilation tube with wire (Kurz)

Otologic implant; Aids in hearing; Unsafe

80
New cards

MP35N occluder

Cardiac occluder; Treates PDA, ASD, VSD, PFO; Conditional:; 1.5T; Nonferromagnetic; Can be scanned immediately after placement

81
New cards

304V stainless steel occluder

Cardiac occluder; Treats PDA, ASD, VSD, PFO; Conditional; Weakly ferromagnetic; Wait 6 weeks after placement to scan

82
New cards

Palatal system implant assembly

Palatal implant; Treats sleep disordered breathing; Conditional

83
New cards

Duraphase

Penile implant; Penile dysfunction; Inadvisable

84
New cards

Omniphase

Penile implant; Penile dysfunction; Inadvisable

85
New cards

Pessary

Vaginal or rectal ring shaped device; Nonsurgical way to treat pelvic support defects; Safe; Metallic components cause significant artifacts

86
New cards

Pillcam

Capsule endoscopic device; Ingested capsule camera for visualization of the GI tract, moved through system by peristalsis, used to diagnose various small intestine diseases; Unsafe

87
New cards

Prometra programmable pump

Drug pump; Intrathetcal infusion of morphine; Conditional

88
New cards

RF bion microstimulator

Peripheral nervous system stimulator; Stimulates PNS; Conditional:; Wait 6-8 weeks post op to scan; 1.5T; Heating risk; Only certain pulse sequences allowed; Check for function post MRI

89
New cards

Reveal plus insertable loop recorder

Loop recorder; Single use programmable ECG recorder for patients at risk for cardiac arhythmias; Conditional; Contains no leads

90
New cards

St Jude implantable cardiac monitor (SJM ICM)

Cardiac monitor; Records ECG for patients with increased risk of arrhythmias and transient syndromes; Unsafe

91
New cards

SAM sling

Pelvic belt; Stabilizes open pelvic fractures; Conditional:; 3T or less; Contains ferromagnetic springs that must stay firmly in place during MRI

92
New cards

Bioresorbable scaffolds

Vascular support device; Provides support for coronary arteries; Safe; Same benefits as metal stents without using metallic materials

93
New cards

Tantalum scleral buckles

Occular implant; Repairs retinal detachments; Conditional

94
New cards

Alpha magnetic implant

Bone conduction hearing system; Aids in hearing; Conditional implant; Unsafe spacer, processor, headband

95
New cards

Synchrommed

Drug infusion pump; Infuses medication; Not recommended; MRI temporarily stops rotor of pump

96
New cards

Theraseed

Radioactive seed implant; Delivers low level radiation to prostate gland; Conditional; 1.5T

97
New cards

Deponit (nitro system)

Transdermal patch; Medication patch on skin; Should be removed; Caused a second degree burn from aluminum component

98
New cards

Verichip microtranspoder

Mini implanted radio frequency identification device (RFID); Implanted passive identification device; Conditional:; 7T or less

99
New cards

Neurocontrol vocare

Sacral nerve stimulator/ neuroprosthesis; Bladder control stimulator with both internal and external component; Conditional:; 1.5T