What is biophotonics?

The technology that focuses on the interaction of biological materials with light and other forms of radiant energy whose quantum unit is the photon

2
New cards

Define radiation in the context of biophotonics

Energy that comes from a source and can travel through material or space

3
New cards

Four main biomolecules that compose tissues and cells

DNA, proteins, lipids, and carbohydrates

4
New cards

Four ways light can interact with biomolecules

Reflection, absorption, transmission, and light scattering

5
New cards

What physical principle is the Bradford assay based on?

The absorption of light as a function of wavelength

6
New cards

What gives a material its color in terms of light interaction?

The removal (absorption) of specific wavelengths from visible light

7
New cards

Absorption wavelength and color of the Coomassie dye alone (without protein)

Absorbs blue light at 470 nm, making the dye a reddish-brown color (cationic state)

8
New cards

Absorption wavelength and color of the protein-dye complex

Absorbs yellow wavelengths at 595 nm, making the protein-dye complex blue (unprotonated state)

9
New cards

Main components of a spectrophotometer

A light source that generates specific wavelengths, a sample cuvette path, and a detection sensor that reads light emission/absorption

10
New cards

Peak absorbance wavelength set on the spectrophotometer for the Bradford assay

595 nm

11
New cards

Purpose of colorimetric assays using standard curves

To determine the concentration of unknown samples by measuring absorbances of solutions of known concentrations

12
New cards

Three colorimetric methods for determining total protein content mentioned in the text

Biuret, Lowry, and Bradford

13
New cards

Characteristics of the Biuret protein assay

The oldest method, commonly used in high school labs, involves chelation and redox reactions, and is the least sensitive of the three

14
New cards

Characteristics of the Lowry protein assay

Involves two redox reactions, is more sensitive than Biuret, but is affected by interference from many common laboratory reagents and chemicals

15
New cards

Characteristics of the Bradford protein assay

The most sensitive of the three methods, uses Coomassie Brilliant Blue G-250, and is relatively unaffected by many common laboratory reagents.

16
New cards

Who first described the Bradford protein assay and in what year?

M. Bradford in 1976

17
New cards

Dye used in the Bradford protein assay

Coomassie Brilliant Blue G-250

18
New cards

Chemical form and color of Coomassie G-250 in the Bradford solution before binding

Cationic state, reddish-brown color, with a peak absorption at 470 nm

19
New cards

Chemical form and color of Coomassie G-250 after binding to proteins

Stable unprotonated blue form, with absorption maximum shifting to 595 nm

20
New cards

Primary molecular interaction between Coomassie G-250 and proteins

Electrostatic interactions between negatively charged sulfate groups on the dye and arginine (a very basic amino acid).

21
New cards

Secondary (weaker) dye-protein interaction involving aromatic rings

Electron stacking interactions between the aromatic rings of Coomassie G-250 and aromatic amino acids like tryptophan

22
New cards

Tertiary (weaker) dye-protein interaction with polar amino acids

Weak hydrophobic interactions with polar amino acids having hydrophobic R-groups, such as tyrosine (and phenylalanine)

23
New cards

Four main steps of the Bradford assay procedure

(1) Prepare dilution series of known standards and unknowns

(2) Add Bradford dye and incubate for 5–60 min

(3) Measure A595 in a spectrophotometer

(4) Compile data into a standard curve to determine unknown concentrations

24
New cards

Incubation time requirements for the Bradford assay

At least 5 minutes, but not to exceed 60 minutes

25
New cards

What protein is most abundant in milk?

Casein

26
New cards

Total amino acid count and molecular mass of Casein

224 amino acids with a molecular mass of 24,967 daltons

27
New cards

Number and types of strong Coomassie-binding amino acids in Casein

13 total: 4 arginines (R), 1 tryptophan (W), 4 tyrosines (Y), and 4 histidines (H).

28
New cards

Molecular mass comparison between Coomassie dye and a typical amino acid

Coomassie is ~854 daltons, compared to an average of ~110 daltons per amino acid.

29
New cards

How Coomassie dye interacts with a typical protein in solution based on size

Because Coomassie is much larger than amino acids, a few dye molecules bind and "coat" the protein in solution

30
New cards

What graph type is used to plot raw absorbance data vs. concentration for the standard curve?

Linear graph paper (or graphing utilities like Microsoft Excel)

31
New cards

What does a high correlation coefficient (R2 > 0.9) indicate?

A high degree of linearity in the data, meaning the standard curve fits well and can accurately estimate unknown values

32
New cards

What are the axes assignments when generating a Bradford standard curve in this lab?

Measured absorbance (A595) on the y-axis plotted against known protein concentration (mg/mL) on the x-axis.

33
New cards

Initial preparation step for testing milk samples in Laboratory Activity 1

Prepare a 1:50 dilution of the milk samples using 1x PBS (e.g., 4uL milk added to 196uL 1x PBS)

34
New cards

What solution is used as the "blank" in the Bradford cuvettes?

1x PBS (with Bradford dye reagent added)

35
New cards

Volume of Bradford dye reagent added to each cuvette

1 mL (of 1x Bradford dye reagent).

36
New cards

Volume of standards, blank, or diluted samples added to each cuvette

20uL

37
New cards

What material is used to cover each cuvette before mixing?

Parafilm (small pieces to seal cuvettes)

38
New cards

Mixing technique used after sealing cuvettes with Parafilm

Invert each cuvette 3 times to mix

39
New cards

Spectrophotometer instrument used for quantitative evaluation in Lab Activity 2

DeNovix Spectrophotometer (DS-11x).

40
New cards

Proper orientation when loading a cuvette into the DeNovix spectrophotometer

Make sure the clear window of the cuvette is placed in the direction of the arrow

41
New cards

Critical warning regarding re-blanking the instrument after running the standard curve

DO NOT REBLANK THE INSTRUMENT!

42
New cards

Why must an optional dilution factor be entered into the DeNovix software?

To automatically multiply and correct the calculated concentration if the sample was diluted prior to the assay (e.g., the 1:50 milk dilution).

43
New cards

What does the Reports tab show on the DeNovix after data collection?

A list of sample names, concentrations (mg/mL), dilution factors, recalculated concentrations, assay type, absorbance, and R2 values.

44
New cards

Formula used to calculate standard serial dilution volumes (V1V_1) in Laboratory Activity 3

C1V1 = C2V2 solved as V1 = (C2V2)/C1

45
New cards

How is the volume of 1x PBS calculated when making standard serial dilutions from a stock?

Subtract the calculated V1 volume from the total target volume (e.g., 50uL - V1 = PBS volume)

46
New cards

Mathematical definition of the coefficient of determination (R2) given in the text

R2 = 1 - (SSRES/SSTOT) = 1 - Ei(yi - y^i)2 / Ei(yi - y-)2

47
New cards

What does an R2 value of 1.0 mean?

All the variation in the yy values is perfectly accounted for by the xx values (zero residual error from the regression line).

48
New cards

What does an R2 value of 0 mean?

None of the variation in the yy values is accounted for by the xx values (no linear relationship).

49
New cards

What does a low R2 value indicate about pipetting in this lab?

High variability and poor precision/accuracy in pipetting skills, leading to inaccurate concentration readings of unknown samples

50
New cards

When a MedTech gets a low R2 discrepancy in clinical sample runs, what is typically investigated first?

Human technique errors (the technician's pipetting skills), as humans have a greater propensity for variability than certified instruments and controls