Quiz 02 - Ch 5 & 6 (Bldg Cons. for Fire Prot)

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/24

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 3:25 AM on 10/1/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

25 Terms

1
New cards

Incipient

The initial stage of a fire after ignition, usually involving a single or small number of combustibles

2
New cards

Free burning

The secondary stage of a fire in which it spreads to adjacent combustible materials

3
New cards

Flashover

A transition stage in which exposed surfaces within the compartment ignite simultaneously and fire spreads throughout the compartment. _____ results in full room involvement

4
New cards

Smoldering/decay

A stage in which glowing combustion takes place, without flame. A fire may be forced into the ____ stage when key components of the fire tetrahedron are in short supply, such as when the oxygen supply is limited

5
New cards

What are the four stages of fire development?

  1. Incipient

  2. Free burning

  3. Flashover

  4. Smoldering/decay


6
New cards

Entrained air

Air that is being fed into the fire, typically lower to the ground

7
New cards

Bidirectional flow

The movement of cooler air (oxygen) into the room and hot gases leaving the room from the ceiling layer

8
New cards

Fire plume

The column of flames

9
New cards

Entrainment

Fresh air drawn into the fire from the doorway

10
New cards

Thermal runaway

A dangerous reaction where a lithium-ion battery overheats uncontrollably

11
New cards

Autoexposure

The vertical spread of fire on the exterior of a multistory building, from one floor to the floor(s) above via convection and radiation

12
New cards

Smoke explosion

Trapped unburned products of combustion mixed with sufficient oxygen explode when an ignition source is present

13
New cards

Fire walls

Wall with a fire-resistive rating and structural stability that separates buildings or subdivides a building to prevent the spread of fire; fire walls are typically 2- to 4- hour rated and are used to create “separate buildings” within an overall structure

14
New cards

Fire partitions

A fire-rated assembly that subdivides a building to prevent the spread of fire, such as between dwelling units in a multiple-unit dwelling; typically 1-hr rated and is used to create fire-resistive corridors and to separate tenant spaces in covered mall buildings

15
New cards

Inherent fire resistance

The resistance of a structural member to collapse by fire because of the nature of its material or assembly

16
New cards

Fire resistance ratings

Are concerned with the length of time a particular building assembly will continue to perform its structural and/or barrier function in the face of an assault by a standard fire test

17
New cards

Flame spread ratings

Are concerned with the rate at which fire spreads over the surface of a material, the smoke it develops, and the fuel it contributes to a fire

18
New cards

Steiner Tunnel Test

Evaluates the surface burning characteristics of building materials, also known as ASTM E-84 and UL 723

19
New cards

ASTM E-108 (UL790), Standard Test Methods for Fire Tests of Roof Coverings

A test to assess resistance of the roof to an external fire, the fire spread of a roofing surface itself, and the propensity of roofing to generate more burning brands

20
New cards

ASTM E-119

Standard test method used to evaluate the fire-resistance duration, structural integrity, and load-bearing capacity of building construction assemblies like walls, floors, roofs, and columns

21
New cards

Fire barriers

Are typically 1- to 2-hour fire resistance-rated and used to enclosed shafts, exit stairwells, exit passageways, and horizontal exits, and to separate spaces from certain hazardous areas.

22
New cards

Fire resistance of columns

Concerned with resisting collapse

23
New cards

Fire resistance of floors AND walls

Concerned with resistance of passage of fire and collapse

24
New cards

Fire resistance of doors

Concerned with passage of fire

25
New cards

Radiant Panel Test (ASTM E-162)

A standard test method that measures and compares the surface flammability of materials using a radiant heat energy source