1
New cards

Flat Panel Detector Evolution

  • Referred to as digital radiography (DR)

  • Introduced in 1995

  • Manufacturers are striving to improve quality and functionality

  • Flat panel detector is a commonly used term (panel)


2
New cards

Dector configuration (types)

  • Direct

  • Indirct


3
New cards

Direct (Uses)

  • Photoconductor

  • Amorphous selenium (a-Se), thin-film transistor (TFT)


4
New cards

Direct (selenium)

  • An active layer

  • Semi conductor, excellent x-ray photo detection ability


5
New cards

Direct (when taking an x-ray)

  • High voltage charge applied to the top surface to selenium layer

  • Ionization causes X-ray photons to interact with selenium atoms, freeing electrons from being collected by electrodes at the bottom of the selenium layer

  • Charges collected at TFT (read/processed line-by-line)


6
New cards

Indirect (uses)

  • Scintillator


7
New cards

Indirect (Steps included)

1) Use a scintillator to convert X-ray photons to light first

2) Convert the light energy to an electronic signal

8
New cards

2 methods of collecting electronic signal

  • Thin-film transistor

  • Charge-coupled device (CCD)


9
New cards

Thin film transistor (indirect)

  • Uses amorphous silicon (think layer)

  • Works as a light detector


10
New cards

Charge-couple device (indirect)

  • Photodetector

  • Released line by line to the ADC

  • Electronic signal sent to the computer for processing

CMOS is similar tech

11
New cards

Indirect (Scintillation material types)

  • Cesium iodide (CsI)

  • Gadolinium Oxysulfide (Gd2O2S)


12
New cards

Electronic signal capture (three technologies)

  • Thin-Film Transistor (TFT)

  • Charge-coupled Device (CCD)

  • Complementary Metal-Oxide-Semiconductor (CMOS)


13
New cards

Thin film transistor (TFT)

  • Both indirect/direct use this

  • Electric charges as an array or matrix of pixel-size detector elements (DEI)

  • Once DEI collects signal called dexel

  • DEI has switch/sensing/storage are

  • Pixel size directly related to DEI size

  • Read pixel/[ixel and column-by-column basis

  • Fill factor


14
New cards

Fill factor

Determined by the percentage of DEL consisting of sensing material (affects image quality)

Higher fill factor therefore better spactical contrast resolution

15
New cards

Charge-coupled device (CCD)

  • Photodetector

  • Released line by line to ADC

  • Electronic signal sent to computer for processing


16
New cards

Complementary Metal-Oxide-Semiconductor

  • Similar to CCD, attached to scintillator material

  • CMOS sensors more susceptible to noise when compared to CCD

  • Light sensitivity tends to be lower


17
New cards

Image Acqusition, processing, and display

  • Regardless of conversion type: results in a latent image (will be processed)

  • Readout completed in logical sequence

  • Difference: only exposed elements are used for the image

  • Image processing similar to CR processing

  • DR panels capable of pre-processing and post-processing (Pre-processing permits DEL calibrations)

  • Image display is the final step (just like CR)


18
New cards

DR Panel Features (two general classes)

1) Portable detectors

2) Integral detectors

19
New cards

Portable dectors

  • Wireless

  • Hard-wired with tether cable


20
New cards

Integral Detectors

  • Typically hard-wired to radiographic equipment


21
New cards

DR Panel Features

  • Two general classes

  • Sophisticated Piece of electronics

  • Manufacturers continue to improve features


22
New cards

Auto-detection technology

  • DR panels typically require communication with an X-ray generator

  • Interface is vendo-specific (can be expensive)(Limits versatility of panel usage in various rooms)

  • New DR panels elimate traditional generator interface


23
New cards

Auto-detection technology cont’d

  • Panels wireless

  • Presence of X-ray panels triggers the TFT plant to collect signals

  • No true generator interface

  • Exposure terminated by manual timing or automatic exposure control (AEC)

  • TFT charged by on-board capacitor prior to exposure

  • Data read-out completed; panel recharges for next exposure


24
New cards

DR Panel Precautions

  • Respect the level of sophistication a DR Panel represents

  • Damage panels sent to the manufacturer for analysis

  • Fluid invasion (incase in protective bags)

  • Weight-load restrictions and bending (standing feet, portable exams on obese patients, etc.).

  • Avoid panel dropping (drop protection insurance)

  • Clean panels according to manufacturer recommendations

  • Newer panels have less weight and improved durability

  • Your responsibility to know and understand DR panel restrictions from the manufacturer.