Code Notes 4

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/19

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 4:19 PM on 10/12/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

20 Terms

1
New cards

The power supply to the mobile home shall be a feeder assembly consisting of not more than one listed _ ampere mobile home power supply cord or a permanently installed feeder

50 Amperes

2
New cards

The area around an outdoor, grade level gasoline dispensing pump extending up to 18 inches above the grade level and within _ horizontally is classified as a class 1, division 2 location.

20’ feet

3
New cards

Each patient bed location should be provided with a minimum of _ receptacles with specific circuits.

14

4
New cards

Capable of being inadvertently touched or approached nearer than a safe distance by a person defines which of the following terms

Exposed (as applied to live parts)

5
New cards

Article 480 covers _

Stationary standby batteries

6
New cards

Dry type transformers exceeding 112 ½ kVA shall not be located within _ of combustible material

12’’ in (Article 450.22)

7
New cards

Manufactured wiring system Definition


8
New cards

LED sign illumination system Definition

9
New cards

A _ in accordance with 705.10 shall be provided at each PV system disconnecting means.

Directory

10
New cards

Article _ covers electrical equipment, lighting accessories, and wiring systems used to connect contained within, or installed on office furnishings.

605.6(C)

11
New cards

What is Article 668

12
New cards

Irrigation cable for electrically driven irrigation machines is required to be supported at intervals not exceeding _

4 feet

13
New cards

Were can you NOT use cable tray

Hoist ways or anywhere subject to physical damage

14
New cards

Cable splices and cable joints are permitted in a cable try provided they are _

Accessible

15
New cards

Cable tray system Definition

16
New cards

Cable trays must have _ strength and rigidity to provide adequate support for all contained wiring.

Suitable

17
New cards

Surface metal raceways shall not be used where the voltage is _ or more between conductors unless it has the thickness of not less than 0.040 in. nominal

300V

18
New cards

Surface metal raceway and associated fittings shall be _

Listed

19
New cards

Surface metal raceways shall not be used where subject to severe physical damage, unless otherwise _

Approved

20
New cards

Where covers and accessories of non-metallic materials are used on surface metal raceways, they shall be _ for such use

identified