Home
Explore
Exams
Login
Get started
Home
Day 36 — Temperature Gauge
Day 36 — Temperature Gauge
0.0
(0)
Rate it
Studied by 0 people
Call Kai
Learn
Practice Test
Spaced Repetition
Match
Flashcards
Knowt Play
Card Sorting
1/73
There's no tags or description
Looks like no tags are added yet.
74 Terms
View all (74)
Star these 74
1
New cards
2
New cards
3
New cards
4
New cards
What is the title of the Day 36 calibration infographic?
Temperature Gauge: How do we check a temperature gauge against a reference?[cite: 17
5
New cards
What learning journey series does this infographic belong to?
90-Day Calibration Learning Journey: Beginner to Calibration Specialist 2026[cite: 17
6
New cards
What page layout format is used for the Day 36 infographic?
Page 1/2 and Page 2/2[cite: 17
7
New cards
How is a temperature gauge defined in Section 1?
A temperature-measuring instrument that indicates temperature
8
New cards
How does the construction of a temperature gauge vary?
Its construction varies depending on the design and the manufacturer[cite: 17]
9
New cards
What specific type of dial gauge is illustrated as an example in Section 1?
A bimetallic dial gauge is shown as an example[cite: 17]
10
New cards
What is an indication defined as in the key terms table?
Displayed or pointed temperature[cite: 17]
11
New cards
What is a reference temperature defined as in the key terms table?
Value from a suitable calibrated reference[cite: 17]
12
New cards
How is error defined in the key terms table?
Indication minus reference[cite: 17]
13
New cards
How is correction defined in the key terms table?
Reference minus indication[cite: 17]
14
New cards
What is a scale interval defined as in the key terms table?
Difference between adjacent scale marks[cite: 17]
15
New cards
What is a tolerance or specification defined as in the key terms table?
Allowed limit set by the applicable requirement[cite: 17]
16
New cards
What are the common temperature gauge designs covered in Section 3?
Bimetallic dial thermometers
17
New cards
How does a bimetallic dial thermometer operate?
It uses the different expansion of bonded metals to move a pointer on a dial[cite: 17]
18
New cards
How does a filled-system thermometer operate?
It uses a temperature-dependent response of a filled system such as liquid or gas[cite: 17]
19
New cards
What components make up a remote-reading sensor-and-indicator system?
A temperature sensor like an RTD or thermocouple with a separate indicator[cite: 17]
20
New cards
What must a technician confirm before choosing a calibration method?
The actual construction and model[cite: 17]
21
New cards
What equipment setup is shown in Section 4 for a typical comparison?
A temperature source such as a stirred bath or suitable source
22
New cards
How should the sensing portions be positioned within the temperature source?
At suitable and comparable positions in the temperature source[cite: 17]
23
New cards
What does the suitability of a typical comparison setup depend on?
Its suitability depends on the specific model and applicable procedure[cite: 17]
24
New cards
What is the first step in the pre-calibration checks checklist?
Identify make
25
New cards
What physical components of the gauge must be inspected during pre-calibration?
The pointer
26
New cards
What documentation must be obtained prior to calibration?
Manufacturer specification and approved procedure[cite: 17]
27
New cards
What must be verified regarding the reference standard and temperature source?
Check the reference thermometer and source suitability[cite: 17]
28
New cards
What operational parameters must be planned ahead for the setup?
Plan test points and safe setup parameters including mounting
29
New cards
What warning is given when no specific gauge model is provided?
Do not assume a universal accuracy limit
30
New cards
What reference temperature value R is used in the illustrative worked example?
100.0 degrees Celsius[cite: 18]
31
New cards
What gauge indication value I is used in the worked example?
102.0 degrees Celsius[cite: 18]
32
New cards
How is the error calculated in Step 1 of the worked example?
Indication minus reference which equals +2.0 degrees Celsius[cite: 18]
33
New cards
How is the correction calculated in Step 2 of the worked example?
Reference minus indication which equals -2.0 degrees Celsius[cite: 18]
34
New cards
What is the technical interpretation of the worked example result?
The gauge indicates 2.0 degrees Celsius higher than the reference at this point[cite: 18]
35
New cards
What is the corresponding correction value for the worked example point?
The correction is -2.0 degrees Celsius[cite: 18]
36
New cards
Does a single calibration point establish overall acceptance or rejection?
No
37
New cards
What additional factors are required to make a conformity decision?
The applicable specification
38
New cards
What does measurement uncertainty depend on according to Section 7?
The instrument
39
New cards
What is the first common uncertainty contributor listed in Section 7?
Reference temperature calibration uncertainty[cite: 18]
40
New cards
What does reference temperature calibration uncertainty cover?
The accuracy and stability of the reference thermometer[cite: 18]
41
New cards
What is the second uncertainty contributor listed?
Temperature source stability and uniformity[cite: 18]
42
New cards
What does temperature source stability and uniformity involve?
Variation and gradients in the bath or source[cite: 18]
43
New cards
What is the third uncertainty contributor listed?
Gauge resolution or readability[cite: 18]
44
New cards
What does gauge resolution or readability represent?
The smallest scale division or dial resolution[cite: 18]
45
New cards
What is the fourth uncertainty contributor listed?
Repeatability[cite: 18]
46
New cards
What does repeatability account for in calibration?
Variation in repeated readings[cite: 18]
47
New cards
What is the fifth uncertainty contributor listed?
Installation or immersion effects[cite: 18]
48
New cards
What do installation and immersion effects involve?
Correct insertion depth
49
New cards
What is the sixth uncertainty contributor listed?
Hysteresis where relevant[cite: 18]
50
New cards
What does hysteresis describe in temperature gauges?
The difference between increasing and decreasing temperature[cite: 18]
51
New cards
How must these uncertainty factors be combined to obtain final uncertainty?
Use the combination of these factors with the GUM to obtain the measurement uncertainty[cite: 18]
52
New cards
What is the first common mistake listed in Section 8?
Using one method for all temperature gauges such as bimetallic
53
New cards
What is the second common mistake listed?
Wrong immersion depth or installation position[cite: 18]
54
New cards
What is the third common mistake listed?
Taking readings before stabilization[cite: 18]
55
New cards
What is the fourth common mistake listed?
Confusing error with correction[cite: 18]
56
New cards
What is the fifth common mistake listed?
Ignoring the manufacturer's specification or applicable procedure[cite: 18]
57
New cards
What is the sixth common mistake listed?
Assuming one passing point ensures the whole range is OK[cite: 18]
58
New cards
What is the seventh common mistake listed?
Calibrating only the display and not the actual sensing element[cite: 18]
59
New cards
What is the first item in the practical tips and checklist in Section 9?
Identify the gauge type
60
New cards
What is the second item in the practical checklist?
Inspect the dial
61
New cards
What is the third item in the practical checklist?
Use a suitable reference and temperature source[cite: 18]
62
New cards
What is the fourth item in the practical checklist?
Follow the correct insertion and immersion requirements[cite: 18]
63
New cards
What is the fifth item in the practical checklist?
Allow adequate stabilization time[cite: 18]
64
New cards
What is the sixth item in the practical checklist?
Record readings at specified points including increasing and decreasing if required[cite: 18]
65
New cards
What is the seventh item in the practical checklist?
Calculate error
66
New cards
What is the eighth item in the practical checklist?
Compare with applicable specification and decision rule[cite: 18]
67
New cards
What is the final item in the practical checklist?
Document results and any observations[cite: 18]
68
New cards
What is the technical question in the Your Turn Calibration Challenge?
If the reference temperature is 120.0 degrees Celsius and the gauge indicates 118.5 degrees Celsius
69
New cards
What is the correct answer to the technical challenge question?
The error is -1.5 degrees Celsius and the correction is +1.5 degrees Celsius[cite: 18]
70
New cards
What is the witty question presented in the calibration challenge?
Why did the temperature gauge break up with the thermometer?[cite: 18]
71
New cards
What is the witty answer provided in the challenge?
It felt like it was always getting compared[cite: 18]
72
New cards
What is the practical scenario question in the calibration challenge?
The gauge shows unstable readings during operation
73
New cards
what would you check first?[cite: 18]
74
New cards
What standards and references are listed at the bottom of the infographic?
ASME B40.200 Thermometers Direct Reading and Remote Reading