Lecture 5: Enhancing Patient Safety in Biomedical Engineering

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/24

flashcard set

Earn XP

Description and Tags

Vocabulary practice flashcards covering medical technology regulation, safety standards, risk management, and clinical engineering roles from Lecture 5: Enhancing Patient Safety.

25 Terms

1
New cards

Patient Safety (Clinical Engineering perspective)

The prevention of patient harm arising from the selection, use, maintenance, and management of healthcare technology throughout its entire lifecycle.

2
New cards

Health Technology Management (HTM)

The discipline that integrates medical technology, financial stewardship, and patient safety to ensure equipment safety, improve clinical outcomes, and optimize equipment management.

3
New cards

Regulation

A best practice identified by a group of experts that is generally required and enforceable by law.

4
New cards

Code

A detailed set of guidance recommendations that may be, and frequently are, adopted into law by legislative or governing bodies.

5
New cards

Standard

A documented agreement containing technical specifications, rules, guidelines, and definitions to ensure products, processes, and services are fit for purpose, whose compliance is generally voluntary unless cited in law.

6
New cards

Technical Information Report (TIR)

A review of technical issues relevant to a technology containing expert consensus opinions and guidelines rather than mandatory requirements, not subject to public review.

7
New cards

Medical Devices Directorate (MDD)

The national authority under Health Canada that evaluates and monitors the safety, effectiveness, and quality of diagnostic and therapeutic medical devices through pre-market reviews and post-market surveillance.

8
New cards

Class I Medical Device (Health Canada)

A medical device representing the lowest potential risk (such as a wheelchair), which does not require an individual device licence but is tracked through establishment licensing.

9
New cards

Class IV Medical Device (Health Canada)

A medical device presenting the greatest potential risk (such as an implantable cardiac pacemaker), requiring a full medical device licence before sale in Canada.

10
New cards
<p>Patient Care Environment</p>

Patient Care Environment

The closely regulated physical space around a patient bed extending 1.5 m1.5\,\text{m} horizontally from the bed perimeter and 2.3 m2.3\,\text{m} vertically above the floor, typically accommodating approximately 1212 to 1515 medical devices.

11
New cards

Tracer Methodology

An accreditation evaluation process where an auditor follows a high-risk patient from admission to discharge to examine care delivery and evaluate all interactions between the patient and medical technology.

12
New cards

Use Error

A medical device error related to device usability, user interface design, or systemic operating conditions, accounting for up to one-third of reported device errors rather than individual operator fault.

13
New cards

ISO/IEC 62366

The international standard defining the application of usability engineering to medical devices in order to identify and mitigate risks associated with use error.

14
New cards

Standards Council of Canada (SCC)

The federal crown corporation that oversees Canada's national standardisation network and designates official standards by prepending 'CAN' to standard identification codes.

15
New cards

CSA Z32

The Canadian standard on Electrical Safety and Essential Electrical Systems in Health Care Facilities, establishing shock current limits and classifying procedures into cardiac, body, and casual contact.

16
New cards

Cardiac Contact

A procedure classification under CSA Z32 that carries the greatest risk of electric shock because of direct electrical contact with the heart, requiring the most stringent leakage current limits.

17
New cards

Body Contact

A procedure classification under CSA Z32 representing a moderate risk of electrical shock to a patient.

18
New cards

Casual Contact

A procedure classification under CSA Z32 representing the least risk of electrical shock to a patient.

19
New cards

Required Organizational Practice (ROP) 10.5

An Accreditation Canada requirement mandating that healthcare leadership implement, document, and evaluate an effective preventive maintenance program for medical devices and technology.

20
New cards

Medical Device Recall (FDA)

A method of removing or correcting products violating laws administered by the Food and Drug Administration, classified by hazard severity as Class I (most serious), Class II, or Class III.

21
New cards

21 CFR 810

The specific federal regulation that grants the United States FDA the authority to issue a mandatory medical device recall order.

22
New cards

ECRI Alerts Tracker

A specialized healthcare technology management tool used by clinical engineering teams to receive, track, and manage hazard notices and medical device recalls.

23
New cards

Creativity

The production of original ideas that are considered valuable.

24
New cards

Innovation

The successful implementation and introduction of new, useful ideas into practice.

25
New cards

Divergent Thinking

A problem-solving strategy guided by four principles: deferring judgment, striving for quantity, making unusual connections, and seeking novelty.