1/17
Vocabulary practice flashcards covering properties, exposure limits, health effects, origins, and emergency treatments for the seven core gases described in the Hewan Mine documentation.
Atmospheric Air
A natural gas mixture composed of 78.09% N, 20.94% O, 0.94% argon, 0.03% CO2, and trace amounts of other gases that supplies the oxygen necessary for life.
Carbon Dioxide (CO2)
A non-flammable gas with a specific gravity of 1.53, an 8-hour TWA TLV of 5,000ppm, a 15-minute STEL of 30,000ppm, and an IDLH of 40,000ppm that may produce an acid taste at high concentrations.
Biological Oxidation
A natural rotting process of organic materials that generates carbon dioxide and can lead to an oxygen-deficient atmosphere.
"Jelly Legs"
A symptom of carbon dioxide exposure occurring at 10,000ppm, characterized by weakness in the knees, feeling hot and clammy, lack of attention to detail, fatigue, anxiety, and loss of energy.
Carbon Monoxide (CO)
A gas with a specific gravity of 0.97, an explosive range of 12.5–74%, an 8-hour TWA of 25ppm, a STEL of 190ppm, and an IDLH of 1,200ppm, generated by incomplete combustion of carbon-based materials.
Backdraft
An event occurring in confined, oxygen-starved mine fires for which high concentrations of carbon monoxide may be partially responsible.
Carbon Monoxide Physiological Action
The mechanism whereby carbon monoxide readily binds to blood hemoglobin, severely reducing the oxygen-carrying capacity of the blood.
Hydrogen Sulfide (H2S)
A flammable gas with a specific gravity of 1.19, an explosive range of 4.3–46%, a TWA of 10ppm, a STEL of 15ppm, and an IDLH of 100ppm, known for its distinct rotten-egg odour.
Cytotoxic Anoxia
A cellular pathology induced by hydrogen sulfide (H2S) exposure that blocks the body's cells from utilizing oxygen.
Olfactory Fatigue
The loss of the sense of smell occurring at 100ppm after 2 to 5minutes or at 100–150ppm of hydrogen sulfide, misleading workers into believing the hazardous gas has cleared.
Nitrogen Dioxide (NO2)
A non-flammable gas with a specific gravity of 1.59, appearing reddish-brown in pure form with a pungent, acrid, sweetish, or bleach-like odour detectable at 0.04 to 5ppm, formed by burning or detonating nitrate explosives.
Pulmonary Edema (NO2 Exposure)
A potentially fatal buildup of fluid in the lungs resulting from nitrogen dioxide inhalation, typically presenting after a latent period of 3 to 30hours post-exposure.
Permissible Oxygen (O2) Volume Range
The required mine atmospheric oxygen concentration, which must not fall below 19.5% or rise above 23% by volume.
Safety Lamp Flame Extinction
The historical threshold at which a candle flame or safety lamp flame is extinguished due to oxygen deficiency, occurring at approximately 16% oxygen.
Anoxia
Oxygen deficiency in the body, the first clinical signs of which appear when atmospheric oxygen levels decline to 16%.
Radon (Rn)
A non-flammable, chemically inert radioactive decay product of the uranium decay series with a specific gravity of 7.8, subject to exposure limits of 50mSv/yr and 100mSv over a 5-year period.
Radon Progeny
A collective series of radioactive decay isotopes produced by radon, chronic exposure to which is associated with lung cancer.
Radon Mine Ventilation
The primary and most effective engineering control used to prevent the dangerous buildup of radon and radon progeny entering through broken rock or radon-bearing water.