Big idea
HVAC systems maintain indoor comfort and air quality by controlling temperature, humidity, ventilation, and air movement. Interior designers must coordinate HVAC with furniture, ceilings, lighting, partitions, and room layouts.
HVAC
Stands for Heating, Ventilating, and Air Conditioning.
Heating adds heat to a space.
Ventilation brings in outdoor air and removes indoor air.
Air conditioning cools and may also control humidity.
Central HVAC system
A central system produces heating or cooling at a central location.
Air or water is distributed throughout the building.
Examples include central boilers, chillers, and air-handling systems.
Local HVAC system
A local system serves an individual room or a small area.
Examples include window air conditioners, PTAC units, and room heaters.
Local systems may allow occupants to control conditions independently.
Thermal zoning
Definition: Dividing a building into areas with separate temperature controls.
Each zone can respond to different occupancy, orientation, and heat-gain conditions.
Example: A sunny conference room may need more cooling than an interior storage room.
Heating load
The amount of heat required to maintain the desired indoor temperature.
Heat loss through walls, roofs, windows, floors, and air leakage affects heating load.
Cooling load
The amount of heat that must be removed to maintain the desired indoor temperature.
Solar gain, people, lights, equipment, and outdoor air affect cooling load.
Air handling unit (AHU)
A central unit that conditions and circulates air.
Common components include fans, filters, heating coils, cooling coils, and dampers.
It may mix outdoor air with return air before distributing conditioned air.
Fan coil unit (FCU)
A local unit that uses a fan to move air across a heating or cooling coil.
Often used in hotels, apartments, and other multi-room buildings.
May be part of a two-pipe or four-pipe system.
Packaged terminal air conditioner (PTAC)
A self-contained heating and cooling unit commonly installed through an exterior wall.
Often used in hotels and individual apartment rooms.
Provides local room control.
Constant air volume (CAV)
Supplies a relatively constant volume of air.
Temperature is adjusted to meet the heating or cooling demand.
Remember: CAV = constant airflow volume.
Variable air volume (VAV)
Changes the volume of conditioned air supplied to a space based on demand.
Often uses terminal boxes to control airflow.
Can improve energy efficiency when properly designed.
Remember: VAV = variable airflow volume.
Underfloor air distribution (UFAD)
Supplies conditioned air through a raised-floor plenum.
Air is delivered through floor diffusers near occupants.
Can support flexible office layouts.
Furniture and partitions must not block airflow.
Heat pump
Transfers heat from one location to another.
Can provide heating and cooling by reversing the refrigeration cycle.
It moves heat rather than generating all heat through electric resistance.
Evaporative cooling
Cools air by evaporating water.
Works best in hot, dry climates.
Adds moisture to the air.
Less effective in humid climates.
Absorption cooling
Uses heat energy to drive a refrigeration process.
May use natural gas, steam, or waste heat.
Differs from conventional vapor-compression cooling, which uses a mechanical compressor.
Refrigeration cycle
A process that moves heat from one area to another.
Main components include the evaporator, compressor, condenser, and expansion device.
The refrigerant absorbs heat at the evaporator and releases heat at the condenser.
Diffuser
A device that distributes conditioned air into a room.
Often located in the ceiling.
Its shape and throw pattern affect air movement and comfort.
Register
A grille that includes a damper or means of controlling airflow.
Can be used for supply or return air depending on the system.
Grille
An opening with bars or a framework that allows air to pass.
May be used for supply, return, or exhaust air.
Return air
Air drawn from the room back into the HVAC system.
It may be filtered and recirculated.
Supply air
Conditioned air delivered into the room.
Exhause air
Air removed from the building and discharged outdoors.
Outdoor air
Fresh air brought into the building for ventilation.
Ductwork
A network of ducts that carries supply, return, and exhaust air.
Duct size and routing must be coordinated with ceiling heights, beams, lights, and other services.
Ventilation
Provides outdoor air to dilute indoor pollutants and support indoor air quality.
Removes odors, moisture, and contaminants.
Heat recovery ventilator (HRV)
Transfers heat between outgoing exhaust air and incoming outdoor air.
Helps reduce energy loss while providing ventilation.
Generally transfers heat, not moisture.
Energy recovery ventilator (ERV)
Transfers heat and some moisture between outgoing and incoming air streams.
Can help manage both temperature and humidity loads.
Indoor air quality (IAQ)
Refers to the quality of air inside a building.
Affected by ventilation, filtration, moisture, materials, cleaning products, and occupant activities.
Commissioning
A process of checking and verifying that building systems are installed and operate as intended.
Helps identify problems before the building is fully occupied.
HVAC efficiency terms
EER: Energy Efficiency Ratio. Measures cooling output compared with electrical energy input under specified conditions. Higher generally means more efficient.
SEER: Seasonal Energy Efficiency Ratio. Measures cooling efficiency over a seasonal range of conditions. Higher generally means more efficient.
AFUE: Annual Fuel Utilization Efficiency. Measures how efficiently a furnace converts fuel energy into useful heat. Higher means more efficient.
COP: Coefficient of Performance. Ratio of useful heating or cooling energy moved to energy consumed. A higher COP means more heat moved per unit of energy used.
IPLV: Integrated Part Load Value. A chiller efficiency metric that considers operation at different loads. It is useful because chillers often operate below full capacity.
Codes, figures, and clearances
Commercial energy standard: ASHRAE 90.1.
Commercial ventilation: ASHRAE 62.1.
Residential ventilation: ASHRAE 62.2.
Residential heating design maximum in notes: 72°F.
Residential cooling design minimum in notes: 75°F.
Programmable thermostat heating preset in notes: 70°F or lower.
Programmable thermostat cooling preset in notes: 78°F or higher.
Bathroom heating reference: At least 68°F / 20°C.
HVAC floor area: 10–15% of building floor area.
Residential energy attributed to HVAC: 39%.
Commercial energy attributed to HVAC: 32%.
Duct drawing allowance in notes: Add 2 inches to inside duct dimensions for wall thickness/insulation.
Furniture/screens: Even items under 5 ft high can block air circulation.
UFAD ceiling height reference: At least 9 ft.
Room AC EER minimum cited: 11 (2023 DOE single-package room AC).
Central AC SEER minimum cited: 14 North / 15 South.
Wood stove and fireplace clearances
Open fireplace efficiency: About 10%.
With outside combustion air / doors: 20–30%.
Masonry heaters: May burn up to 99% cleanly, as stated in the notes.
Wood stove clearance from combustible wall: 36 inches minimum.
With noncombustible heat shield: 18 inches.
Uninsulated metal chimney to combustibles: 18 inches minimum.
Reflected ceiling plan (RCP) Coordination
Coordinate ducts, diffusers, lights, sprinklers, ceiling grids, and access panels.
Allow for duct insulation.
Keep supply diffusers away from tall partitions or furniture that blocks air throw.
Example: A tall storage unit placed in front of a diffuser can create a stagnant or uncomfortable area.
Hotels and multi-tenant buildings
Independent rooms may need independent heating/cooling control.
A 4-pipe FCU or PTAC arrangement can allow one room to heat while another cools, depending on the system design.
Modern workplaces
UFAD and VAV can support flexible layouts and individual air delivery.
Employees may adjust floor swirl diffusers at desks.
Raised floors can also support reconfigurable power/data distribution.