1/72
Looks like no tags are added yet.
What are the three traditional speech frequencies?
500 Hz, 1,000 Hz, and 2,000 Hz.
What does PTA stand for?
Pure-tone average.
How do you calculate the pure-tone average?
Add the hearing thresholds at 500, 1,000, and 2,000 Hz and divide by three.
What is the PTA if thresholds are 10, 10, and 40 dB HL?
20 dB HL.
What does SRT stand for?
Speech reception threshold.
What should the pure-tone average generally correspond with?
The speech reception threshold (SRT).
What is the relationship between PTA and SRT?
They should generally be in agreement.
Which three frequencies did the professor specifically emphasize for the exam?
500, 1,000, and 2,000 Hz.
What is the definition of dynamic range given by the professor?
The range of usable hearing between the softest detectable sound and the loudest tolerable sound.
What does a telecoil receive?
A non-acoustic electromagnetic signal.
What does non-acoustic mean?
Not a sound wave.
True or false: A telecoil picks up acoustic sound signals through the microphone.
False. It receives electromagnetic signals.
What is another way to describe an electromagnetic signal in the telecoil lecture?
A non-acoustic signal.
What hearing aid features did the professor say to review?
Directional microphones, data logging, telecoils, noise suppression, memories, and Bluetooth.
Which hearing aid feature uses microphones to emphasize sounds from particular directions?
Directional microphones.
What is data logging in a hearing aid?
A feature that records information about hearing aid use.
What is noise suppression in a hearing aid?
A feature designed to reduce unwanted background noise.
What are hearing aid memories?
Stored hearing aid settings or listening programs.
What is Bluetooth connectivity used for in hearing aids?
Wireless connection and audio streaming from compatible devices.
Which cochlear implant image did the professor say to know very well?
The cochlear implant diagram showing its components and electrodes.
What part of a cochlear implant electrically stimulates auditory nerve fibers?
The electrode array.
Where is the cochlear implant electrode array located?
Inside the cochlea.
What cochlear implant components should you be able to identify on a diagram?
Microphone, speech processor, transmitter coil, internal receiver-stimulator, electrode array, and auditory nerve.
What is prelingual hearing loss?
Hearing loss that occurs before language develops.
What is postlingual hearing loss?
Hearing loss that occurs after language develops.
Which auditory training theorist did the professor remind students to review?
Carhart.
Which types of hearing loss can have good speech discrimination?
Conductive hearing loss and mixed hearing loss with a small sensorineural component.
Why does conductive hearing loss generally preserve speech clarity?
It reduces sound transmission and loudness without necessarily damaging the cochlea.
Why can sensorineural hearing loss affect speech discrimination?
Damage involving the cochlea or auditory nerve can reduce speech clarity.
Can someone with mixed hearing loss have good speech discrimination?
Yes, especially if the sensorineural component is small.
Does mixed hearing loss always cause poor word understanding?
No. It depends partly on the severity of the sensorineural component.
What is an air-bone gap?
The difference between air conduction and bone conduction hearing thresholds.
What does an air-bone gap indicate?
A conductive component of hearing loss.
What is the pathway of air conduction?
Sound travels through the outer ear, middle ear, and inner ear.
What does bone conduction bypass?
The outer and middle ear.
How does bone conduction stimulate hearing?
It vibrates the skull and stimulates the cochlea.
What air-bone gap did the professor use as a significant example?
15 dB or more.
True or false: Pure sensorineural hearing loss must have an air-bone gap of 15 dB or more.
False. Pure sensorineural hearing loss does not have a significant air-bone gap.
What type of hearing loss has an air-bone gap with normal bone conduction?
Conductive hearing loss.
What type of hearing loss has an air-bone gap and elevated bone conduction thresholds?
Mixed hearing loss.
What type of hearing loss generally has elevated air and bone thresholds without a significant gap?
Sensorineural hearing loss.
What do O and X typically represent on an audiogram?
Unmasked right-ear and left-ear air conduction thresholds.
How is bone conduction tested?
Using a bone vibrator placed against the skull.
What does FM stand for?
Frequency modulation.
What is an FM wireless system?
A system that transmits a speaker's voice from a remote microphone directly to a listener's hearing device.
Why are FM systems useful in classrooms?
They improve speech understanding by reducing the effects of distance and background noise.
What does SNR stand for?
Signal-to-noise ratio.
What is the signal in a classroom SNR example?
The teacher's voice.
What is the noise in a classroom SNR example?
Unwanted background sounds.
What does a higher signal-to-noise ratio mean?
The desired speech signal is stronger relative to background noise.
Why is SNR often worse at the back of a classroom?
The teacher's voice becomes weaker with distance while background noise remains.
What is the main advantage of an FM system?
Improving the signal-to-noise ratio.
Why might students with hearing aids still need an FM system?
Hearing aids amplify sound but do not eliminate the effects of distance, noise, and reverberation.
What is reverberation?
Sound reflecting off surfaces and lingering in a room.
What is dynamic range?
The difference between the softest detectable sound and the loudest comfortably tolerable sound.
Why may someone with hearing loss have a reduced dynamic range?
Their hearing threshold may be elevated while their loudness discomfort level remains relatively high.
What approximate loudness level did the professor use in his pain-threshold example?
110 to 120 dB.
What is the difference between CROS and BiCROS?
CROS routes sound to a good ear; BiCROS routes sound to a better ear that also needs amplification.
Why does BiCROS require amplification in the better ear?
Because that ear also has hearing loss.
Does a traditional CROS system need to amplify sound for hearing loss in the better ear?
No. The better ear has normal or near-normal hearing.
What does a telecoil replace in the professor's example?
The hearing aid microphone as the active input.
What does a telecoil pick up?
An electromagnetic signal rather than an acoustic sound signal.
Why can a telecoil make phone calls easier in noise?
It can receive the phone's signal without relying on the hearing aid microphone to pick up room sounds.
What is a difference between a telecoil and an FM system?
A telecoil receives electromagnetic signals, while an FM system uses a remote microphone to transmit speech to a hearing device.
Can bone conduction stimulate both cochleae?
Yes.
How can a BAHA help someone with one unaidable ear?
It transmits sound through bone to the better-functioning cochlea.
What does binaural mean?
Both ears.
What does monaural mean?
One ear.
What are two advantages of binaural amplification?
Improved sound localization and better speech understanding in background noise.
What is sound localization?
The ability to identify where a sound is coming from.
Why can BTE hearing aids accommodate more severe hearing losses?
Their larger design can accommodate more powerful amplification.
Why may CIC hearing aids be unsuitable for profound hearing loss?
Their small size limits amplification power.
Which hearing aid can accommodate both mild and profound hearing loss?
BTE.