1/39
Forty vocabulary flashcards covering the principles, instrumentation, workflows, and applications of mass spectrometry and proteomics described in Chapter 9.
Mass Spectrometry
An analytical technique whose central purpose is to identify ions by mass-to-charge ratio (m/z), enabling mass and structural analysis.
Three Components of a Mass Spectrometer
Ionization source, mass analyzer, and detector.
Mass-to-Charge Ratio (m/z)
The ratio of mass to charge; multiplying m/z by charge magnitude approximately recovers the ion mass.
Role of Mass Spectrometry in Proteomics
Enables protein identification and the study of modifications, interactions, and networks.
Figure 9.1 (Textbook)
An illustration showing a yeast protein–protein interaction network with interconnected functional complexes.
Electron Ionization (EI)
A hard ionization technique where electron bombardment transfers high energy, often causing extensive fragmentation.
Limitation of Electron Ionization for Proteins
Large, nonvolatile, thermally fragile biomolecules cannot readily be analyzed intact.
Chemical Ionization (CI)
An ionization technique in which ionized reagent gas reacts with analyte, generally producing less fragmentation than electron ionization.
Fast Atom Bombardment (FAB)
An ionization method in which high-energy atoms strike analyte contained in a liquid matrix.
Soft Ionization
Ionization techniques, such as MALDI and ESI, that produce biomolecular ions with relatively little fragmentation.
Matrix-Assisted Laser Desorption/Ionization (MALDI)
A soft ionization method where a laser strikes matrix crystals, causing desorption and ionization of the analyte.
MALDI Matrix
A chemical matrix whose purpose is to absorb laser energy and assist analyte desorption and ionization.
Typical MALDI Ion Charge State
Singly charged ions, commonly [M+H]+ ions.
Droplet Breakup in Electrospray Ionization (ESI)
Evaporation increases charge density until electrostatic repulsion destabilizes droplets.
Analysis of Large Proteins by ESI
Multiple charging lowers the m/z into the measurable instrument range.
Practical Difference Between ESI and MALDI
ESI utilizes charged solution droplets, whereas MALDI utilizes laser irradiation of a matrix.
Time-of-Flight (TOF) Mass Analyzer
An analyzer that separates ions accelerated to equal kinetic energy by flight time, where ions with lower m/z arrive sooner.
TOF Flight Time Relationship
Flight time is proportional to m/z under equal acceleration conditions.
Reflectron
An ion mirror in TOF analysis that compensates for kinetic-energy differences and increases the effective flight path.
Quadrupole Mass Analyzer
A mass analyzer that uses RF and DC electric fields to allow selected m/z values to pass stably.
Ion Trap
A mass analyzer that stores ions and can eject or fragment them selectively.
Fourier Transform Ion Cyclotron Resonance (FT-ICR)
A mass analyzer operating on ion cyclotron motion in a magnetic field, where induced signals are Fourier-transformed.
Major Advantage of FT-ICR
Extremely high mass resolution and mass accuracy.
Combination of Ion Sources and Analyzers
The pairing of different sources and analyzers to optimize ionization, mass range, resolution, sensitivity, and fragmentation.
Intact Protein Mass Measurement
Measurement that reveals protein mass, clues to protein identity, and possible modifications or adducts.
Peptide Mass Fingerprinting (PMF)
Matching measured peptide masses from an enzymatic digest against predicted database digests.
Digestion Prior to Peptide Mapping
The generation of smaller peptides that provide measurable masses and sequence-specific identification evidence.
Trypsin Cleavage Specificity
Cleaves proteins after lysine (K) or arginine (R), generally except when followed by proline.
Tandem Mass Spectrometry (MS/MS)
A procedure where a precursor ion is selected, fragmented, and its product ions are analyzed.
b Ions and y Ions
Peptide fragment ions where b ions retain the N-terminus and y ions retain the C-terminus.
Peptide Sequencing by MS/MS
Identifying amino-acid residues from the mass differences between adjacent fragment ions.
Leucine and Isoleucine in Mass Spectrometry
Amino acids that are difficult to distinguish by MS because they share identical residue masses, preventing ordinary mass differences from distinguishing them.
Hydrogen–Deuterium Exchange MS (HDX-MS)
A technique used to investigate protein solvent accessibility and conformational dynamics.
Native Mass Spectrometry
Mass spectrometry aimed at studying intact noncovalent complexes and their stoichiometry.
Proteomics
The large-scale study of proteins, their expression, modifications, interactions, and functions.
Typical Proteomics Workflow
Extract proteins, separate, digest/analyze by MS, and identify using databases.
Two-Dimensional Gel Electrophoresis
A separation method that resolves proteins first by isoelectric point (pI), then by molecular mass.
LC-ESI-MS Coupling
Liquid chromatography coupled to electrospray ionization mass spectrometry, where LC separates complex mixtures and ESI continuously introduces eluting analytes into the MS.
Limitation of Gene Sequence Alone
A gene sequence suggests function but does not prove activity, regulation, or interactions.
Functional Genomics
A field that complements proteomics by linking genes to biological roles using expression, perturbation, and protein evidence.