Unit 3 Study Guide

0.0(0)
Studied by 4 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/44

encourage image

There's no tags or description

Looks like no tags are added yet.

45 Terms

1
New cards

Turbo factor is another name for

Echo train length (ETL)

2
New cards

What is the effect of increasing TR on image weighting?

It may change image weighting depending on other parameters

3
New cards

What defines a single-shot FSE sequence?

All k-space lines are acquired in one TR period

4
New cards

What type of pulse sequence uses a 180° rephasing pulse to generate an echo?

Spin-echo

5
New cards

What is the echo in MRI?

Signal detected at TE made of rephased magnetic moments

6
New cards

What is pathology weighting in MRI?

IR image with long TE showing bright pathology

7
New cards

The pulse sequence that uses multiple 180° RF rephasing pulses to fill multiple lines of k-space is

Fast spin echo (FSE)

8
New cards

What does phase reordering do in MRI?

Reorders gradient amplitudes and polarities for phase encoding

9
New cards

What effect does a higher echo train length (ETL) have on FSE images?

Increases T2 weighting

10
New cards

The long TR and long TE results in which type of image weighting?

T2

11
New cards

Which sequence is commonly used to suppress fat signal?

STIR

12
New cards

Compared to conventional spin echo sequences, fast spin echo (FSE) sequences

Always have short scan times

13
New cards

What regenerates the echo in a gradient-echo pulse sequence

Gradient reversal

14
New cards

What is the effective TE in a turbo spin echo?

The TE that best reflects image weighting

15
New cards

The time from the 180° RF inverting pulse to the 90° RF excitation pulse is called the

TI

16
New cards

Which sequence is typically used for brain imaging to see lesions adjacent to CSF?

FLAIR

17
New cards

in STIR sequences, "tau" refers to

Time between 90° and 180° pulses and from there to the echo

18
New cards

What is the primary purpose of FLAIR sequences in MRI?

Suppress cerebrospinal fluid (CSF) signal

19
New cards

The echo train length (ETL) is associated with which sequence?

Fast spin echo

20
New cards

What type of RF pulse is used to generate a spin echo?

180

21
New cards

What type of RF pulse does an inversion recovery sequence begin with?

180

22
New cards

The Larmor frequency is affected by the application of RF pulses.

False

23
New cards

A spin-echo is produced by

A 180° RF pulse following excitation

24
New cards

The point in time where there is no longitudinal magnetization of fat in STIR is called the __________

Null point

25
New cards

Inversion recovery sequences increase signal from

Contrast-enhanced structures

26
New cards

In Fast Inversion Recovery sequences, which tissue signal is often suppressed?

Fat

27
New cards

The scan time for a FSE sequence can be calculated as TR x NSA x (_________):

Number of phase encodings/ ETL

28
New cards

The time it takes for spins to dephase immediately after the 90° RF pulse is called:

Tau

29
New cards

What does TI represent in inversion recovery sequences?

Time from 180° inversion to 90° excitation

30
New cards

T2* decay is eliminated by the 180° RF pulse.

True

31
New cards

The effective TE in TSE sequences is used to determine _____________.

Image weighting

32
New cards

Which parameter affects the scan time of a sequence?

NSA (Number of Slices Acquired) , Number of phase encoding steps, TR (ALL OF THE ABOVE)

33
New cards

What is the purpose of a 180° RF rephasing pulse?

To rephase magnetic moments in the transverse plane

34
New cards

STIR sequences are particularly useful in musculoskeletal imaging because they:

Suppress fat signal effectively

35
New cards

What is the purpose of triple IR prep?

Null both fat and blood

36
New cards

In a Fast Spin Echo sequence, scan time is reduced by:

Increasing the number of phase encoding steps per TR

37
New cards

The method of filling k-space where all lines are filled at once is called:

Single shot turbo spin echo

38
New cards

What is an echo train in MRI?

Series of 180° pulses and echoes

39
New cards

T1-weighted images are typically produced using which combination of TR and TE?

Short TR and short TE

40
New cards

What is the benefit of using dual echo sequences?

Provide both PD and T2 weighted images

41
New cards

The phenomenon where fat remains bright on T2-weighting images due to reduced spin-spin interactions is called:

J coupling

42
New cards

A sequence that uses a 180-degree rephasing pulse to generate an echo is called a:

Spin echo

43
New cards

RARE is another name for:

Turbo spin-echo

44
New cards

Reducing ESP (echo spacing) in FSE sequences helps to minimize:

Image blurring

45
New cards

What is the primary function of a DRIVE sequence?

Achieve high signal from water with short TR