Comprehensive practice flashcards covering instrumentation (microtome mechanics, blade profiles, cryostats), tissue section preparation (water baths, slide adhesives, drying, mounting), and the chemical and physical theories of histological staining.

53 Terms

1
New cards

What is the primary function of microtomy and a microtome?

Microtomy is the process of preparing thin, transparent slices of biological tissue post-embedding for microscopic examination using an instrument called a microtome.

2
New cards

What are the three main structural components shared by all microtomes?

All microtomes consist of a base (body), a knife plus knife attachment/holder, and a tissue/block holder.

3
New cards

How does a rotary microtome operate, and what is the typical thickness range for paraffin sections?

The tissue block moves up and down while advancing a preset number of micrometers per wheel revolution. The typical paraffin section thickness is 3–6 μm3\text{--}6\,\mu\text{m} (frequently 4–5 μm4\text{--}5\,\mu\text{m} or one cell thick).

4
New cards

How does a sliding microtome function, and what specimen types is it designed to cut?

The tissue block remains stationary while the cutting blade moves horizontally across it; it is used primarily for celloidin and large paraffin blocks.

5
New cards

What section thicknesses and knife types are utilized on an ultramicrotome?

It cuts ultrathin sections of approximately 90 nm90\,\text{nm} for electron microscopy and approximately 0.5 μm0.5\,\mu\text{m} plastic sections for light microscopy using glass, diamond, or sapphire knives with an adjacent water bath.

6
New cards

What are the characteristics and principal disadvantages of a traditional freezing microtome?

It clamps to a benchtop, uses a bulky, hazardous CO2CO_2 cylinder to freeze tissue, cuts sections at approximately 10 μm10\,\mu\text{m}, and causes CO2CO_2 freezing that destroys antigens needed for immunohistochemistry (IHC).

7
New cards

What materials, coatings, and profiles are typical for disposable microtome blades?

They are made of austenitic stainless or carbon steel, often coated with chromium, platinum, or Teflon, and are manufactured in high-profile (more robust, used in cryostats) and low-profile formats.

8
New cards

What are the distinguishing shapes of knife Profiles A, B, C, and D?

Profile A is strongly planoconcave or biconcave (prone to vibration/chatter on tough tissues); Profile B is planoconcave; Profile C is wedge-shaped (robust and commonly used); and Profile D is plane-shaped.

9
New cards

What is the clearance angle on a microtome, and what are its standard settings?

The clearance angle (blade tilt) is the angle between the block face and the lower cutting facet of the knife; it is the only knife angle adjusted on the microtome and is typically set to 3∘–8∘3^\circ\text{--}8^\circ for paraffin sections and 5∘–8∘5^\circ\text{--}8^\circ for resin or frozen sections.

10
New cards

What are the standard measurements for the bevel angle and wedge angle of a microtome knife?

The bevel (cutting) angle formed by the upper and lower cutting facets is approximately 27∘–32∘27^\circ\text{--}32^\circ, while the wedge angle is approximately 15∘15^\circ prior to sharpening.

11
New cards

What are the angle of tilt, slant angle, and rake angle of a microtome knife?

The angle of tilt is approximately 25∘25^\circ (or ∼20∘\sim 20^\circ optimum in diagrams; ∼30∘\sim 30^\circ in cryostats) between the block face and the line bisecting the bevel angle; the slant angle is 10∘ to 14∘10^\circ\text{ to }14^\circ between the lower knife side and the block surface; and the rake angle is between the upper cutting facet and a line perpendicular to the block face.

12
New cards

What is the purpose of a knife back during manual sharpening?

A knife back maintains a constant bevel angle during manual sharpening.

13
New cards

What critical safety and cleaning rules must be observed when handling microtome knives?

Always clamp the tissue block before attaching or exposing the knife, lock the handwheel and engage the knife guard before touching the knife or changing blocks, clean accumulated wax with a soft brush or rough gauze (never use xylene, which leaves an oily residue that stops ribboning), and dispose of blades in puncture-proof sharps containers.

14
New cards

What is a cryostat, and what are its standard operating temperatures?

A cryostat is a stainless steel rotary microtome housed within a refrigerated cabinet maintained at approximately −20∘C to −25∘C-20^\circ\text{C}\text{ to }-25^\circ\text{C} for routine tissues, and approximately −10∘C-10^\circ\text{C} for softer or lipid-rich tissues such as liver, brain, spleen, and lymph nodes.

15
New cards

What are the major diagnostic indications and advantages of frozen sections?

Rapid STAT intraoperative diagnosis (∼15 min\sim 15\,\text{min}), preservation of fat/lipids that dissolve in routine paraffin processing solvents, demonstration of heat-labile enzymes, and retention of undenatured proteins for immunofluorescence and IHC.

16
New cards

What is OCT compound, and how should tissue frozen in it be prepared and stored?

OCT is a glycol-based Optimum Cutting Temperature embedding medium that supports tissue and prevents brittleness. Tissue must be frozen rapidly (using a heat extractor or isopentane in liquid nitrogen) to prevent ice crystal holes and stored wrapped at −70∘C-70^\circ\text{C} to avoid dehydration.

17
New cards

How is the cryostat anti-roll plate properly aligned, and what happens if its temperature or height is incorrect?

It must be aligned parallel to and slightly above the blade edge to stop curling. If it is too warm, sections stick to it; if too low, sections ride over the top; if too high, the block rubs against it; and if sections curl upon lifting the plate, warm air is entering the cabinet.

18
New cards

What biosafety precautions and routine maintenance must be practiced inside a cryostat?

Because frozen tissue is unfixed and potentially infectious, operators must wear gloves, clear debris frequently with alcohol-dampened gauze or a vacuum, wipe surfaces with 70%70\% alcohol prior to UV decontamination, and ensure sections are never left inside during automatic defrost cycles.

19
New cards

What causes thick/thin or skipped sections in microtomy, and how is it corrected?

It is caused by a clearance angle that is too slight (causing the block to compress and expand) or too great, or by loose screws/chuck clamps. It is corrected by adjusting the clearance angle, tightening all chuck and knife clamps, or servicing worn parts.

20
New cards

What causes chatter, washboarding, or curling during sectioning, and how is it resolved?

It is caused by an excessively steep clearance angle, a dull knife edge, or hard/over-dehydrated tissue. The quick fix is to reduce the clearance angle, move to a fresh blade area or replace the blade, and hydrate/cool the tissue or cut at a slower pace.

21
New cards

What causes a curved or crooked paraffin ribbon, and what is the corrective action?

It occurs when the top and bottom edges of the block are not parallel, or when there is an uneven temperature or a dull spot on the blade. The fix is trimming the block edges parallel, eliminating drafts/heat sources, and moving the blade to a sharp spot.

22
New cards

What causes scratches or vertical splits in microtomy sections?

They are caused by a nick or debris on the blade edge, or by hard calcifications or bone inside the block. If the scratch moves after shifting the blade, replace the blade; if the scratch remains in the exact same tissue location, the block contains hard material.

23
New cards

What causes static electricity or flying sections during microtomy, and how can it be managed?

It is caused by low ambient humidity. It can be mitigated by gently breathing warm, moist air onto the block face and knife edge and cutting at a steady rate.

24
New cards

How does the mechanical advancement system of a rotary microtome work?

It advances via a screw feed or computerized motor using a ratchet wheel featuring 1,0001\text{,}000 grooves (each notch representing 1 μm1\,\mu\text{m} or 0.001 mm0.001\,\text{mm}) engaged by a metal pin called a pawl.

25
New cards

What is the structural difference between semi-automated and fully automated rotary microtomes?

Semi-automated microtomes feature one motor (automated coarse feed with manual fine wheel, or vice versa), whereas fully automated microtomes utilize two independent motors driving both fine and coarse handwheels, often operated by a foot pedal to free both hands.

26
New cards

How should a paraffin tissue block be oriented, faced, and cooled prior to microtome sectioning?

Orient the block so the edge with the least resistance contacts the knife edge first. Coarse-cut (face) the block at 10–15 μm10\text{--}15\,\mu\text{m} (facing does not require prior chilling), then chill on a cold plate or ice water for ∼1–2 min\sim 1\text{--}2\,\text{min} up to 10–15 min10\text{--}15\,\text{min}.

27
New cards

What is the ideal microtomy cutting pace, and what optical defect occurs if sections exceed 4–5 μm4\text{--}5\,\mu\text{m}?

The ideal cutting pace is approximately 1 rotation per second1\text{ rotation per second}. Sections thicker than 4–5 μm4\text{--}5\,\mu\text{m} display nuclei positioned across multiple focal planes rather than a single focal plane.

28
New cards

What histological processing faults cause the 'Venetian blind' effect, mushy sections, and localized shrinkage?

The 'Venetian blind' effect is caused by a dull knife; mushy sections indicate poor or incomplete dehydration; and hard, shrunken areas stem from excessive heat during paraffin infiltration.

29
New cards

What is the procedural difference between serial sections and step levels?

Serial sectioning retains every sequential ribbon section without interruption (e.g., in embryo research), whereas cutting levels samples distinct depths by collecting sections from consecutive ribbons every 8–10 sections8\text{--}10\text{ sections}.

30
New cards

What temperature should a tissue flotation bath be maintained at, and how is it prepared?

The water bath is maintained at 5–10∘C5\text{--}10^\circ\text{C} below the melting point of the embedding paraffin (typically around ∼45–46∘C\sim 45\text{--}46^\circ\text{C} for paraffin melting at 55–58∘C55\text{--}58^\circ\text{C}), filled with deionized water, and skimmed with lint-free tissue between blocks.

31
New cards

What is the correct technique for floating paraffin ribbons on a water bath, and what happens if left too long?

Float sections shiny side down, touching the trailing edge first to remove wrinkles and air bubbles within approximately 30 seconds30\text{ seconds}. Over-soaking or overheating causes tissue separation and produces a 'parched earth' artifact in delicate structures like brain or renal glomeruli.

32
New cards

How should glass slides be manipulated when picking up tissue from the water bath?

Slides should be submerged and brought up vertically from beneath the floating section so the tissue adheres smoothly and water drains away as it is lifted; slides must never be laid flat while wet.

33
New cards

What physical and chemical forces mediate the adhesion of tissue sections to glass slides?

Adhesion relies on van der Waals forces, hydrogen bonding, and ionic interactions (which represent the strongest adhesive bond).

34
New cards

What are positively charged slides, and why are they considered the routine laboratory standard?

Positively charged slides are glass slides treated to create an electrostatically positive surface that securely binds negatively charged tissue sections, providing superior tissue retention and minimal background staining in routine histology and IHC.

35
New cards

What are the characteristics and limitations of gelatin, Mayer's egg albumin, and celloidin as section adhesives?

Gelatin (0.5–5%0.5\text{--}5\% in water) can support microbial growth and cause acid-fast contamination in water baths; Mayer's egg albumin requires heat-fixing at ∼70∘C/30 min\sim 70^\circ\text{C} / 30\,\text{min} and produces background staining if applied heavily; and celloidin serves as an entrapment medium but poses a flammable ether risk.

36
New cards

What are the recommended parameters for slide drying, and what artifact is caused by excessive heat?

Slides are drained upright and dried around ∼60∘C\sim 60^\circ\text{C} (∼7–15 min\sim 7\text{--}15\,\text{min} forced air or ∼1 hr\sim 1\,\text{hr} oven), or kept below <60∘C< 60^\circ\text{C} (40–50∘C40\text{--}50^\circ\text{C} or room temperature) for IHC. Excessive heat causes 'nuclear bubbling' (trapped water boils and cooks nuclei).

37
New cards

What artifact occurs if wet, incompletely dried slides are placed directly into clearing solvents like xylene?

Water prevents xylene from deparaffinizing the tissue, producing intensely staining 'white spots' across the section.

38
New cards

What is the standard sequence of chemical reagents used in deparaffinization prior to staining?

Xylene (or a clearing agent) removes paraffin wax, followed by descending graded alcohols to remove xylene, and finally water to rehydrate the tissue for aqueous dyes.

39
New cards

What are resinous and aqueous mounting media, and what is the ideal refractive index for mounting?

The ideal refractive index is approximately ∼1.54\sim 1.54. Resinous media (e.g., DPX, Permount) require dehydration/clearing and offer optical clarity and permanent storage. Aqueous media are used when dehydration/clearing solvents would dissolve stains, such as in fat/lipid stains, immunofluorescence, and enzyme histochemistry.

40
New cards

What causes a cloudy appearance under a resinous mountant, and what causes a drying artifact?

A cloudy appearance under a resinous coverslip is caused by residual water remaining in the tissue (since water does not mix with xylene or resin). A drying artifact causes brownish discoloration and glossy nuclei that mimic pyknotic cancer cells.

41
New cards

How do heterochromatin and euchromatin differ in structure and staining affinity?

Heterochromatin is condensed, genetically inactive, and intensely basophilic (e.g., in resting lymphocytes), whereas euchromatin is uncoiled, transcriptionally active, and stains lightly or appears pale/clear.

42
New cards

What are the four physical staining mechanisms described in histology?

Capillary attraction (dye drawn into minute tissue pores), adsorption (surface attraction of dye particles), selective solubility (dye dissolves preferentially in tissue targets over solvents, as in lipid staining), and permeability/porosity (dye diffusion dictated by protein meshwork pore size relative to dye molecule size).

43
New cards

What chemical bond types participate in dye-tissue interactions, and which is predominant in routine histology?

Ionic (electrostatic or 'salt linkage') bonds are the most common in routine histology; covalent bonds are strong electron-sharing bonds seen in PAS and fluorescent antibody staining; and hydrogen and hydrophobic bonds mediate weaker, selective attractions.

44
New cards

What are chromophores, chromogens, and auxochromes in dye chemistry?

A chromophore is a color-bearing chemical configuration (e.g., azo, nitro, quinoid ring); a chromogen is an aromatic compound containing a chromophore that is colored but lacks tissue affinity; and an auxochrome is an ionizing group (e.g., −NH2-NH_2, −COOH-COOH, −SO3H-SO_3H, −OH-OH) that confers tissue-binding capacity, turning a chromogen into a dye.

45
New cards

Why is trinitrobenzene classified as a chromogen rather than a dye, and how does it become picric acid?

Trinitrobenzene is yellow due to its nitro chromophores, but it cannot bind tissue because it lacks an ionizing group. Adding a hydroxyl (−OH-OH) auxochrome converts it into trinitrophenol (picric acid), which is a true dye.

46
New cards

What defines basic (cationic) versus acid (anionic) dyes, and what tissue structures do they target?

They are named according to the charge of their colored dye ion, not solution pH. Basic (cationic) dyes carry positive colored ions and bind anionic tissue targets like nucleic acids (basophilic structures); acid (anionic) dyes carry negative colored ions and bind cationic targets like proteins (acidophilic structures like cytoplasm and collagen).

47
New cards

What is the 'dye charge/pH trap' regarding basic dyes?

Basic dyes are salts derived from colored bases (frequently containing amino −NH2-NH_2 auxochromes), but their working solutions can have an acidic pH below 7.07.0; they are classified as 'basic' due to their cationic colored ion, not an alkaline solution pH.

48
New cards

What are the roles of a mordant, an accentuator, and ripening in histological staining?

A mordant is a polyvalent metal ion that bridges dye to tissue to form an insoluble dye lake; an accentuator boosts staining intensity or efficiency without forming a dye lake (e.g., phenol in carbol fuchsin or KOH in methylene blue); and ripening is the chemical or atmospheric oxidation of hematoxylin into active hematein.

49
New cards

What is the difference between progressive and regressive staining?

Progressive staining applies dye incrementally until the target color intensity is achieved and then stops. Regressive staining deliberately over-stains tissue and subsequently removes excess dye using a differentiating agent.

50
New cards

What are four distinct methods of differentiation used in regressive staining?

Acid differentiation (dilute HClHCl, H2SO4H_2SO_4, or CH3COOHCH_3COOH to break dye-metal-tissue bonds), mordant differentiation (excess weak mordant like FeCl2FeCl_2 pulling dye from tissue), solvent differentiation (graded alcohols stripping dye to generate shades), and oxidizing differentiation (bleaching dyes with agents like potassium permanganate or dichromate).

51
New cards

What are the differences among argyrophilic, argentaffin, and aldehyde reduction silver methods?

Argyrophilic tissues bind silver ions but require an external reducing agent (e.g., hydroquinone or formalin) to produce black metallic silver; argentaffin tissues possess endogenous reducing properties (e.g., melanin) to reduce silver directly; and aldehyde reduction relies on oxidized carbohydrates generating aldehydes that reduce silver complexes.

52
New cards

What are the origins and primary histological applications of carmine, hematoxylin, orcein, and saffron?

Carmine is derived from the female cochineal insect (used with mordants); hematoxylin is extracted from the heartwood of the logwood tree (Hematoxylum campechianum); orcein is obtained from lichens and selectively stains elastic fibers; and saffron is harvested from dried Crocus stigmata for specialized connective tissue trichromes.

53
New cards

How do formalin, potassium dichromate, and picric acid fixatives affect subsequent tissue staining?

Formalin can diminish eosin uptake; potassium dichromate decreases hematoxylin staining while increasing eosin binding; picric acid enhances the binding of acidic (anionic) dyes; and prolonged over-fixation diminishes nuclear basophilia.