Drafting from a static water source requires the D/O to understand:
Basic principles of lift
For each 1000ft (300m) of altitude gain, atmospheric pressure drops by:
0.5 psi (7 kPa)
While drafting, a reading at or close to ___ on the compound gauge indicates the pump as reached supply capacity
22 in Hg (-75 kPa)
The theoretical lift for a fire pumper drafting from a static source at sea level is:
33.8 ft (10 m)
In the fire service, ___ means the greatest height at which any amount of water may be raised through an intake hose to the pump
Maximum lift
The height of a column of water being lifted to provide a reliable fire flow is known as:
Dependable lift
When working with a dry hydrant, pumpers may:
Maintain a safer distance from the water’s edge
In order to use static water supplies located a modest distance from the apparatus, some jurisdictions employ:
An eductor
A safe and efficient manner for fire department tender shuttles to arrive, stage, fill, and depart is a route that:
Is circular
The minimum water depth when drafting with a barrel-type strainer is generally considered to be:
2ft (600 m)
If the D/O cannot establish an adequate draft due to clogging at the strainer, ___ with tank water may dislodge the debris
Back flushing
When using both portable and nonportable water sources, the D/O must avoid:
Cross-connections
When using a swimming pool as a static water source, consideration must be given for:
Access for the fire apparatus
Calculate the volume of a swimming pool that is 40ft (12m) wide, 100ft (30m) long, and has an average depth of 6ft (2m)
C = 1000 x L x W x D
180 000 gal (720 000 L)
Calculate the volume capacity of a swimming pool with a diameter of 24ft (8m) and an average depth of 4ft (1.3m)
C = 1000 × 3.14 x R2 x D
13 565 gal (65 312 L)
Cavitation in a pump can be described as water:
Being discharged faster than it comes into the pump
To avoid pump cavitation, keep discharged rates lower than the:
Intake pressure
An appliance of choice when using a portable tank or swimming pool for drafting is the:
Low-level strainer
The ability of the pump to reach capacity is affected if the water temperature is below:
35oF (1.7oC)
The ability of the pump to reach capacity is affect if the water temperature is above:
90oF (32oC)
While priming the pump for drafting, the master intake gauge should indicate the following for each 1ft (300mm) of lift:
1 in Hg (-3.5 kPa)
When drafting, vacuum measurements come from the difference of pressure at the surface of the water and the:
Eye of the pump’s impeller
NFPA 1900 allows priming of the fire pumps up to 1250 gpm (5000 L/min) to accomplish a draft in up to:
30 seconds
If the D/O notices a gradual increase in vacuum with no change in flow during drafting, this indicates:
A developing blockage