Expiration date determination
it is the time in terms of month and year calculated from shelf-life + date of the last processing stage prior to packaging
Zone IVB
The general conditions for long term stability testing in the ASEAN region are the ‘blank’ conditions (30°C/75% RH)
Zone I - temperate
21°C/45% RH
Zone II - subtropical
25°C/60% RH
Zone III - hot and dry
30°C/35% RH
Zone IVA - Hot and humid climate
30°C/65% RH
Zone IVB - Hot and very humid climate
30°C/75% RH
30°C ± 2°C / 75% ± 5% RH
Long-term (for products in primary containers semi permeable to water vapour)
Min. time period covered by data at submission: 12 months
30°C ± 2°C / RH not specified
Long-term (for products in primary container impermeable to water vapour)
40°C ± 2°C / 75% ± 5% RH or at more stressful conditions
Accelerated
Min. time period covered by data at submission: 6 months
Stress testing
_____ is necessary for analytical method validation, pharmaceutical formulation, identifying, and monitoring potential degradants during stability testing.
30°C, 70% RH (Climatic Zone IV)
Normal storage condition in the Philippines