Limiting Patient Exposure to Ionizing Radiation
Radiographers must limit the patient’s exposure to ionizing radiation by
Employing appropriate radiation reduction techniques
Using protective devices that minimize radiation exposure
Patient exposure can be substantially reduced by using
Proper body or part immobilization
Motion reduction techniques
Appropriate beam limitation devices
Adequate filtration of the x ray beam
Gonadal or other specific area shielding
Suitable technical exposure factor in conjunction with either high speed film screen combinations or computer generated digital images
Correct radiographic film processing techniques or appropriate digital image processing
The elimination of repeat radiographic exposures can also contribute significantly to limiting patient exposure
Patient Protection
Effective Communication
Provide explanation of procedure in clear precise but simple terms
Provide instruction that clearly will avoid motion
Inform patient of any discomfort or paint
Answer question Re: benefits vs. risk of radiation and dose
Patient protections during a diagnostic x-ray procedure should begin with clear concise instructions
Ability of patient to cooperate
Consequences when procedures are not explained for the patient
Benefit of explaining procedure to the patient in simple terms
Giving the patient the opportunity to ask questions
Listening attentively and answering patient questions truthfully in accordance with ethical guidelines
Creating a sense of trust between the patient and radiographer
Consequences of Repeat Images
Additional exposure increases patient dose
Double dose to patient’s skin and possibly the gonads
Repeats resulting from carelessness or poor judgement on the part of the radiographer must be eliminated
Repeat exposure (an additional image) is permissible when recommended by the radiologist for the purpose of obtaining additional diagnostic information
Benefits of a Repeat analysis program
By determining the number of repeats and the reasons for producing unacceptable radiographic images, existing problems and conditions in an imaging dept will be identified
Retake analysis is particularly important in CR and DR
Readjustment of images by computer
Measurement of radiation exposure techniques by a qualified medical physicist
Necessity to develop a policy whereby retaken image files can be recovered for analysis
Other Ways to Avoid Repeat Exposures
Use of immobilization devices
For use with pediatric, geriatric, or incapacitated patients
Requirements for restraining patients
Use mechanical devices as a first resort
Use devices such as: Compression bands, tape, sandbags, sheets, towels, sponges, commercial devices, pigg o stat
Holding patients:
Use human restraint as a last resort
Choose family members friends or other hosp personnel, older individuals are preferred; no one individual should hold routinely
RT should never hold pts
Provide shielding devices to individual holding
Position individual to avoid being exposed to the primary beam
Pregnant women or pts < 18 are not allowed to hold
Use short exposure times
Protective Shielding
Purpose: Required when gonads are in or within close proximity (5cm) to the collimated beam; used when shield does not obscure clinical area of interest
Types
Contact shield:
Flat contact shield; used for PA or AP proj in recumbent positions, decreases exposure by
1mm lead flat contact shield from the female reduces exposure by about 50%
1mm lead contact shield for the male pt reduces exposure 90-95%
Shaped contact shields; Used in recumbent, non recumbent, AP, Oblique, Lateral projections. Decreases exposure by 90-95% Ex: male and female gonads, breast, and lens
Shadow shields: Used effectively in a sterile field or when examining an incapacitated pt
Clear Lead Shield: Replaces conventional gonadal shields; Ex: gonad and breast, made of transparent lead plastic material impregnated with approx 30% lead by weight
Pt Protection
Exposure Factors
Use high kVp (fixed or optimum) and low mAs
Higher energy; more penetrating beam
Gives a smaller absorbed dose
Use positions that will reduce pt dose
Ex: perform skull, facial bones, stenyers projections in prone position to reduce exposure to the eyes by 95%
Ex: extremity, forearm - dose increases when pt is seated facing table
Position accurately when using AEC device to avoid repeats
Air Gap Technique
Reduction of scattered radiation
An alternative procedure to the use of a radiographic grid for reducing scattered radiation during certain exams
Procedure to perform air gap technique
Uses for air gap technique
Removed scatter raditiaon by using an increased OID, improves image contrast
Comparison to grid ration
Pt dose higher than non grid technique
Pt dose about the same as mid ratio grid
High kVp radiography
Over 90 kVp air gap techniques are for the most part ineffective
For chest radiography using 120-140 kVp, air gap techniques may be successful
At less than 90 kVp air gap techniques are more efficient
Post Processing and Quality Control Programs
Use the manufacturers recommendation
Report Malfunctions
Quality control program is essential
Includes regular monitoring and maintenance of all processing and imaging display equipment in the facility
Maximizes the likelihood of producing optimal-quality images
Unnecessary Radiologic Procedures
Nonessential radiologic examinations
Chest x-ray examination on scheduled admission to the hospital
Chest x-ray as part of a pre-employment physical
Lumbar spine examination as part of a pre-employment physical
Chest x-ray or other unjustified examination as part of a routine health checkup
Chest x-ray examination for mass screening for tuberculosis (TB)
Whole-body multi-slice spiral computed tomography (CT) screening
Marked areas in Radiology
Radiation areas are Limited Access Areas:
Unrestricted Area:
Area where radiation level is same as background level
No monitoring, posting or control requirements, no signs
Cannot exceed 2 mrem/hr
These are hallways, waiting rooms, stairwells
Restricted Areas:
Must protect from radiation
Posting Categories:
Radiation Area - radiation warning signs should be posted where radiation level could result in an individuals receiving 5 mrem/hr (or 100 mR in any 5 consecutive days) but 100 mrem in any one hour;
requirement: Controlled Access - “Caution Radiation Area” Sign must be used (3-blade radiation symbol)
High Radiation Area - signs shall be posted at the entrance to any area wherein a person could receive an exposure of 100 mrem or more in one hour
requirement: entrances must have an access control feature such as door interlocks
Very High Radiation Area - where radiation could result in an individual receiving in excess of an absorbed dose of 500 mrem in one hour (applicable to research, not diagnostic radiology)
Radiation Protection - Pregnant Patients
Fetus is most sensitive from the 10th day - 10th week after conception
10-Day Rule – Obsolete by ACR & ICRP (also Bushong recommendation)
Patient Questionnaire/Posting of Signs or Posters/Ask if patient is pregnant
Shield patient when it does not interfere with exam; collimate; use high kVp
Elective Booking - Scheduling of Elective Exams
Considerations for Rad. Exams in Abdominal Region
Limit number of projections
If pregnant patient escapes detection and is irradiated Radiologist/Physicist must:
1st - Calculation/estimation of Fetal Dose by Radiologist
Fetal dose is usually less than 1 rad following a conventional x-ray exam.
2nd - Determine gestational time when exposures occurred
Alternatives - Pregnant Pts
Alternatives:
Continue Pregnancy
Terminate Pregnancy
10-25 rad rule
Below 10 rad a therapeutic abortion is not indicated
Above 25 the risk of latent injury may justify therapeutic abortions
Between 10-25 rad, precise time of irradiation, emotional state of pt and other socio and economic factors contribute to decision
Risk is negligible at 5 rad or less; doses above 15 rad risk of malformations.
Therefore exposure from diagnostic procedures would rarely be the cause for terminating the pregnancy.
Irradiation During an Unknown Pregnancy
If irradiation of an unknown pregnancy occurs, the first step is to list the particulars of the x-ray examination in as much detail as possible.
Irradiating a Pregnant Patient
If the physician feels it is in the best interest of a pregnant or potentially pregnant patient to undergo a radiologic examination, the examination should be performed without delay.
Special effort should be made to minimize the dose of radiation the patient receives to her lower abdomen and pelvic region.
Can be accomplished by
Selecting exposure factors that are appropriate for the examination.
Precisely collimating the radiographic beam to include only the anatomic area of interest.
When the lower abdomen and pelvic region do not need to be included in the area to be irradiated, they should be protected with a lead apron or other suitable protective contact shield so that a developing embryo-fetus does not receive unnecessary radiation exposure.
Pediatric Considerations During Conventional X Ray Imaging
Vulnerability of Children to Radiation Exposure
Children are much more vulnerable to both the late somatic effects and genetic effects of radiation than are adults.
Children require special consideration when undergoing diagnostic x-ray studies.
Appropriate radiation protection methods must be used for each procedure
Children Require Smaller Radiation Doses than Adults Do
Patient Motion and Motion Reduction Methods
Use very short exposure times (select high mA station)
Use effective immobilization
Gaining Cooperation During the Procedure
Use specially designed rooms for pediatric examinations containing suitable entertainment devices and distraction devices
Gonadal Shielding and Gonadal Dose
Concept of internal scatter
Appropriate shielding
When not to shield
Morbid Obesity
Obese patients have an effect on the functionality of imaging equipment
The increased body size have a negative impact on image quality and create technical challenges
Equipment have weight limits
Fluoroscopy towers have a maximum diameter and cannot fit under the tower
Centering on table is important incase you can’t feel land marks. Consider that bony skeleton and most organs are not larger and do not change position.
Larger IR are not always needed for obese patients. Collimator should never be set bigger than IR
Modified exposure techniques need to be used
Need for adequate penetration of the body part
Using a grid can minimize scattering
Keeping repeat images to a minimum