BME 711 cardiovascular SYSTEM

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/41

encourage image

There's no tags or description

Looks like no tags are added yet.

42 Terms

1
New cards

materials transported in the cardiovascular system (materials entering the body)

Oxygen , nutrients, and water

2
New cards

materials transported in the cardiovascular system (materials moved from cell to cell)

wastes, immune cells, antibodies, clotting proteins, hormones, stored nutrients

3
New cards

materials transported in the cardiovascular system (materials leaving the body)

metabolic waste, heat, carbon dioxide

4
New cards

True or false: Each side of the heart functions as an independent pump.

True

5
New cards

what are the site of variable resistance ?

the arterioles

6
New cards

where does the exchange between blood and cells take place?

capillaries

7
New cards

the elastic systemic arteries are described as a pressure reservoir what does this mean?

they maintain blood flow during ventricular relaxation

8
New cards

What serves as an expandable volume reservoir?

systemic veins

9
New cards

Ventricular contraction

pushes blood into the elastic arteries, causing them to stretch

10
New cards

ventricular relaxation

elastic recoil in the arteries maintains driving pressure during ventricular diastole

11
New cards

Arteriole diameter is controlled by tonic release of norepinephrine

moderate signal rate results in a blood vessel of intermediate diameter

12
New cards

what happens as norepinephrine release onto an alpha receptor increases?


blood vessel constricts

13
New cards

what happens as norepinephrine release onto an alpha receptor decreases?

the blood vessel dilates

14
New cards

blood flows because liquid moves from ____ to ____ pressure regions

high low

15
New cards

as blood moves through the vessels, pressure is lost, why?

the friction: resistance

16
New cards

true or false: fluid flows only if their is no pressure gradient

false: positive pressure gradient

17
New cards

does flow depend on the pressure gradient (delta P) or the absolute pressure (P)?

pressure gradient

18
New cards

as the radius of a tube ____, the resistance to flow increases

decreases

19
New cards

how does the body use blood vessel radius to control flow?

by controlling the diameter of vessels, changing resistance

20
New cards

The intrinsic rate of the heartbeat is modulated by sympathetic and parasympathetic neurons. What division controls the blood vessel diameter?

sympathetic

21
New cards

endothelial injury:

the inner lining of the artery(the endothelium) becomes damaged due to factors like high blood pressure, high cholesterol, smoking, or inflammation

22
New cards

lipid accumulation:

low density lipoprotein(LDL, “bad cholesterol”) particles enter the damaged area and become oxidized

23
New cards

the steps of atherosclerosis

endothelial injury, lipid accumulation, inflammatory response, plaque formation, progression and complications

24
New cards

inflammatory response

the body’s immune cells (especially macrophages) move un to clear the oxidized lipids, forming foam cells, which accumulate and create fatty streaks on the arterial wall.

25
New cards

plaque formation

smooth muscle cells migrate and produce extracellular matrix, forming a fibrous cap over the lipid core; this is the atherosclerotic plaque. this results in a self-reinforcing cycle.

26
New cards

progression and complcateions

over time the plaque can enlarge and narrow he artery (causing ischemia, or the cap can rupture, triggering blood clot formation (thrombosis) that can completely block blood flow and result in myocardial infraction (MI)

27
New cards

what happens upon myocardial infraction ?

injury, inflammation and repair, structural changes, functional consequences

28
New cards

after MI injury

part of the heart muscle dies due to a lack of blood flow (the hear muscle is highly dependent on oxygen and nutrients)

29
New cards

inflammation and repair after an MI

the surveying myocardium compensates for the lost function by stretching the vertical calls thin; leading to dilation (enlargement) and altered geometry (from an oval to a more spherical shape)

30
New cards

functional consequences after an MI

these changes increase wall stress, reduce pumping efficiency, and can ultimately cause heart failure or arrhythmia

31
New cards

predicting and preventing heart failure Digital Twins

uses a 3-dimensional computational fluid dynamics of the pulmonary arteries to noninvasively predict hemodynamic markers associated with worsening right heart failure.

32
New cards

predicting and preventing electronic vascular conduit

a flexible triboelectric sensor with a small diameter vascular graft to enable real time in situ monitoring of blood flow. The device was successfully tested in small animals and nonhuman primates, demonstrating stable biocompatibility, wireless data transmission, and early identification of vascular blockages.

33
New cards

Problems with drug eluting stents (DES)

Mechanical mismatch, neointimal hyperplasia, delayed re-endothelization , impaired vascular function

34
New cards

mechanical mismatch (DES)

the stiffness of metal can irritate the vessel wall

35
New cards

neointimal hyperplasia (DES)

excessive growth pf sooth muscle cells causes the artery to narrow again (restenosis).

36
New cards

delayed re-endothelization (DES)

the drugs that prevent restenosis also slow the growth of healthy endothelial cells, delaying vessel healing

37
New cards

Impaired vascular function

the vessel wall loses some ability to respond to normal physiological signals (e.g. dilation)

38
New cards

treatment: stents

bioengineers engineered vascular stents coated with mesenchymal stem-cell derived exosomes that are released in response to reactive oxygen species, and they demonstrated in animal models that these exosomes-eluting stents accelerate re-endothelization, reduce neointimal hyperplasia and attenuate local and systemic inflammation compared with traditional drug-eluting or bare-metal stents. they further show that exosomes-stent approach prompted macrophage polarization toward a pre-healing phenotype and enhanced downstream tissue repair beyond just the vessel wall

39
New cards

treatment cardiac patch

3D printing of personalized thick and perfusable cardiac patches and hearts. they demonstrated perfusable vascular networks and viable cardiomyocytes.

40
New cards

Is it risky to remove and replace cardiac tissue? Yes or No

Yes, there is specific structure, shape, and connection of the cardiac tissue.

41
New cards

Treatments cardiac cell-integrated microneedle patch for treating myocardial infraction

the microneedles create direct micro-channels into the injured myocardium . allowing paracrine factors from the Cardiac stromal cells, to be efficiently transferred resulting in enhancing angiomyogenesis, reduced scar formation, and improved cardiac function compared to conventional cell delivery.

42
New cards

E-cardiac patch for synchronous mechanophysiological monitoring and electrocoupling therapy

a polyaniline based hydrogel patch that can adhere spatiotemporally to the epicardial surface, enabling conformal integration self-healing, and high electrochemical performance . continuous in vivo monitoring