1/108
Looks like no tags are added yet.
Who appoints the CFM?
AF/A3O.
Which FM position monitors the health and manning of their career field, within their command, and elevates concerns?
MFM.
Which FM position reports manning information to the MFM for an accurate portrayal of base staffing?
BFM.
Manpower reflects what skill-levels are needed to accomplish the required workload?
The minimum essential level.
Who is the approval authority for all manpower standards applicable to Air National Guard units?
NGB/J1/OM.
What does the AF consider as the primary indicator of experience and/or effectiveness required for assigning enlisted personnel?
Enlisted skill level.
State four products utilized to administer manpower at the unit level.
(1) UMD. (2) UPMR. (3) PEC. (4) ACR.
Why are manpower studies conducted?
To establish or change existing manning within a MAJCOM, base, or work center.
What is the purpose of the AF OA program?
To equip senior leaders and managers of AF personnel and training programs with objective and factual information about AF occupations and civilian occupational series.
What does the airfield operations flight provide to the OSS?
Airfield management and air traffic operations services to the base flying wing, transient, and civil users to include control tower, RAWS, and base operations functions.
Name the OSS flight that coordinates wing combat mission planning and sortie allocation.
OSO.
During contingencies, which squadrons provide the theater AF commander a rapid reaction mobile air control system and a control and reporting center?
Air control squadrons.
What entity creates procedures and applies criteria to worldwide airfield operations throughout the AF?
AFFSA.
What three systems form a complete airfield package?
The AN/TPN-19, together with the AN/MSN-7, and the TACAN.
Who provides in-theater wartime and emergency peacetime restoration of communications and information systems?
The 85 EIS.
What ability does the GTACS provide to the deployable mission?
The ability to rapidly detect and identify airborne targets with minimal or no support.
Who is responsible for developing the MTP?
Supervisors, assisted by the UTM.
What is the backbone of the training plan?
MTL.
Who ensures that trainers are providing a quality OJT product?
Supervisors.
What type of feedback describes what a trainee is doing correctly?
Positive feedback.
Who is able to perform evaluations in the work center?
A MSgt, work center supervisor, or 7-level technician as long as the evaluator is not the individual's trainer.
Who is responsible for overseeing the application of MICT?
Work center NCOIC.
What is a contract index?
A list or spreadsheet that contains all your contracts and important information for each.
As a minimum, what should the contract index contain?
(a) Contract number. (b) POC. (c) Assigned quality assurance evaluator. (d) Brief description of services being supplied. (e) Dollar limitations.
What is the purpose of a change clause?
Authorizes the government to make modifications to the contract.
Why should you use a supplemental agreement instead of a change order?
It lessens the chance of dispute with the contractor.
What is a modification?
Changes to hardware or software to meet increased mission requirements.
List the four steps in the modification proposal process?
(1) Request for actions and organizational validation. (2) Lead and Using command validation. (3) The PM reviews and approves the technical requirements and solution. (4) Lead command certification and approval.
For what length of time are modification documents maintained?
Throughout the modified assets life cycle.
What is ETIMS?
The AF system of record, a secure Web, GCSS-AF application accessible via the AF Portal with the TO catalog ordering and TODO account management functions.
How do you obtain access to ETIMS?
Prospective users must first obtain a CAC or an ECA with a minimum of a favorable NACI to establish access to the AF Portal. Once logged on to the AF Portal home page, ETIMS is accessed from the "Applications A-Z listing."
How are COTS manuals acquired?
COTS manuals are acquired using the USAF TMCR (TM 86-01) for centrally procured and managed (NSNs assigned) equipment, no matter the format, and will be evaluated for effectiveness and content IAW MIL-PRF-32216, Evaluation of Commercial Off-The-Shelf (COTS) Manuals and Preparation of Supplemental Data.
Describe the services the ADX site provides.
The ADX site is the primary site for maintenance and repair information for the DASR and STARS. It is the storehouse that maintains all the TOs and updated adaptation files. It also provides data and collaboration services.
What is your primary mission as a 7-skill level technician?
To ensure that your equipment is able to perform as expected.
What is the purpose of an equipment evaluation?
EEs give an overall view of the quality of RAWS maintenance.
How many AFMQCC MICT checklists should you use when performing an EE?
As many checklists as are applicable to the equipment being evaluated.
How are core EEs different from other EEs?
Regular EEs can be performed on any base equipment item. Core EEs are performed on items listed as "mission essential."
What is the purpose of the equipment status?
The status is a way of letting leadership know if the equipment is operating normally, partially, or is not operating at all.
Which status defines equipment as impaired but usable?
Amber.
Which information system is useful to help managers identify trends and clear up problems?
REMIS.
What reporting system provides the work center with the ability to track equipment inventories, open and close jobs, schedule and document preventive maintenance, and document ancillary training?
IMDS.
What is the purpose of external reporting?
To up-channel the status of assigned resources to leadership.
What is a SITREP?
SITREPs are narrative reports that keep recipients informed of significant outages, events, and/or status and enable higher levels of command to prepare for potential effects of ongoing situations.
Where there is conflicting safety guidance, which guidance should be used?
The guidance that provides the most protection.
When must AFOSH guidance be followed?
At all times.
Who has the authority to grant exemptions to OSHA standards?
Only the DOL.
What is the key to preventing injuries at work?
Understanding what the hazards are and how to deal with them.
What factors determine the severity of electrical shock?
The amount of current flowing through the body, the time of exposure, and the body's physical condition.
What injuries may occur as a result of arcing?
Serious burns to the body and temporary or permanent blindness.
Why is arcing extremely dangerous?
Because you don't actually have to come in contact with the source of electricity.
What safety precautions should you take when working on energized equipment?
(1) Do not wear rings, watches, or other conductive objects. (2) Do not use or carry in pockets metallic objects. (3) Always have a safety observer. (4) Electrical circuits should always be de-energized and locked/tagged out. (5) All workers will know emergency cut-off procedures. (6) Interlocks shall not be permanently bypassed. (7) Grounded railing, barriers, or enclosures shall be used to protect workers from shock.
Define high-voltage?
600 volts or greater.
Who performs health risk assessments for all EMF transmitters owned and operated by communications facilities?
BE.
How do administrative and physical controls prevent EMF exposure to workers?
They provide access restrictions or physical barriers to keep workers out of the exposure area.
What is the difference between a flammable liquid and combustible liquid?
Flammable liquids have a closed cup flashpoint below 100° F; Combustible liquids have a closed cup flashpoint at or above 100° F.
Why is it important to maintain a clean and neat work area?
Messy areas can lead to accidents, which can not only injure personnel but also have a detrimental effect on the work center.
Why should shields be installed on fluorescent light fixtures?
To prevent tubes from falling out or being accidentally damaged.
Who is responsible for maintaining good housekeeping in the work area?
Supervisors and workers.
What four pillars function as a framework for structuring the AF mishap prevention program and activities used to minimize risk of injuries?
(1) Policy & Leadership. (2) Risk Management. (3) Assurance. (4) Promotion & Education.
The pre-departure safety briefing is especially targeted for personnel of what age?
Under the age of 26.
Who plays the largest role in the workcenter safety program?
The workcenter supervisor.
What are three main reasons for grounding?
(1) Personnel safety. (2) Equipment protection. (3) Noise reduction.
What components can be used for lightning protection in a facility ground system?
(a) Air terminals (lightning rods), or overhead ground wires, to protect structures from direct strikes. (b) Down conductors to provide a low impedance path from air terminals to the earth electrode subsystem. (c) Surge arresters to protect the facility from transient voltages propagated along power and communications lines.
What kind of system are the vast majority of signal reference subsystems categorized as in modern facilities.
Multipoint systems.
Define bonding.
Establishing a low-impedance path between two metal surfaces.
What type of metals should hardware be made of when used in the lightning protection subsystem? Why?
Zinc, copper, cadmium, aluminum, and bronze. Because they do not corrode easily.
What is the only type of bond where soft solder is permitted?
Signal reference bonds.
What are the two basic functions of shielding?
Preventing interference between multiple emanating systems (electrical/communications) and minimizing compromising emanations.
Although power leaked by a cable may be a very small percentage of transmitted power, what could it cause?
It could cause significant interference to sensitive circuits.
Why is evaluating all conductive paths for the escape of compromising emanations difficult?
Because there are so many.
Explain triboelectricity.
The process by which electrical charges are developed results from "friction." The resultant charge is called "triboelectricity" (commonly referred to as "static electricity").
List five ways static electricity can be generated in common day-to-day activities.
(1) Walking across the carpet. (2) Walking on a vinyl floor. (3) Working at a bench. (4) Opening vinyl envelopes. (5) Picking up a common poly bag from a bench.
How long will static electricity hold its charge?
Until there is either a slow current discharge flow or a rapid discharge from an electrical spark discharging the electricity.
What are the three different ESD classes and what are their sensitivity to the voltage of the electrostatic charges?
Class 1 (0-999 volts), Class II (1,000-3,999 volts), Class III (4,000-14,999 volts).
Where is the most effective place to work on ESDS items?
A protected workstation.
What are two ways you can reduce ESD while working at a workbench?
Wear a conductive wrist strap and use an ionizing air blower.
What is the maximum surface roughness height for Area "A" of the localizer?
Must not exceed ±0.5 feet.
What must the area surrounding the localizer be free of within a 500-foot radius of the center of the course array?
It must be free of reflecting objects such as buildings, power lines, wire-mesh fences, trees, or parked aircraft.
What can you do to avoid "screening" when siting radar equipment?
Avoid placing the radar in depressions and valleys.
List five things you should consider when siting radio equipment.
(1) The antenna needs to be high above any obstructions. (2) You must rely on the amount of power produced and the siting of the antenna to push the signal farther out into space to the visible receiving end. (3) Antenna matching to the frequency and impedance of the transmitting radio. (4) The horizontal difference and vertical distances between antennas. (5) Ensure you get the frequency allocations from the base frequency manager before transmitting.
When is a FMQ-19 midfield sensor group normally installed?
Where the runway is longer than 8,000 feet, or at a location that must meet Category II criteria.
If help from your base cable and antenna maintenance work center is necessary to accomplish antenna PMIs, what documentation is necessary to outline the duties to be performed?
Coordinate MOA/MOU to outline specific duties if another party is necessary to help maintain the system in any way.
As a good practice, what other general items can be inspected in maintenance facilities and on remote equipment during PMIs?
Check corrosion, equipment racks, the generator/UPS, animals and insects, dust, environmental controls working properly, ice on systems, and frozen water in ground wells or junction boxes.
What do aircrews do when a navigation system's identification is not received, or the identification code is set to "TEST"?
Consider the navigation signal unreliable.
If a system requires certification, under which tab of the facility records would you file the certification paperwork?
Tab 2, PMI.
Name the five basic types of flight inspections.
(1) Site evaluation. (2) Commissioning. (3) Periodic. (4) Special. (5) Surveillance.
What flight check is the only inspection completed on a recurring basis?
Periodic inspection.
What is the basic scheduled interval, in days, that is required for an ASR system periodic flight check?
540 days.
Newly commissioned precision facilities are initially inspected at what intervals before maintaining an established periodic schedule?
At 90, 180, and 270-day intervals.
Name the three key principles that the AEF is founded.
(1) Predictability. (2) Equitability. (3) Transparency.
What AEF principle is essentially describing a "fair share" for taskings?
Equitability.
What are the four key elements of the AEF structure?
(1) Readily available force. (2) Demand force teams. (3) In-place support. (4) Institutional force.
What key element of the AEF structure consists of unique assets that are considered LS/HD?
Demand force teams.
What AEF element are individuals considered deployable even though their organization does not posture UTCs in the AEF capability library?
Institutional force.
Who makes strategic policy decisions that provide the basis for all military planning and programming?
The National Security Council, chaired by the president.
Define deployment planning.
A continuous, iterative, and highly structured process that allows for an orderly transition from peace to war and then to post-hostilities operations.
What type of plan is driven by current events in real time and normally occurs in emergencies and in the context of time-sensitive situations?
Crisis action planning.
What reference details deployment execution responsibilities and procedures for crisis action and deliberate plans, as well as executing the deployment and reception of equipment and personnel?
AFI 10-403.
In the development phase of the deployment sourcing process, who initiates a request for forces?
CCDRs.
What name is given to a tasking when a non-standard sourcing solution is required?
JET.