What is Nonorganic Hearing Loss?
an apparent loss of hearing without any organic disorder or with insufficient pathological evidence to explain the extent of the loss
nonorganic losses can manifest in patients of any gender, age, or socioeconomic background
Reasons why one may display nonorganic hearing loss
monetary compensation — lawsuit from accident, workers’ compensation
desire for affection/attention — especially for children
psychological disorder
to avoid undesirable task
stenger test
widely used for unilateral hearing losses
highly reliable and able to be done using a two channel audiometer
based on principle: if two tones of the same frequency are introduced at the same time in both ears, only the louder sound will be heard
identify presence of nonorganic hearing loss and approx. true hearing thresholds
introduce tone 10 dB above the threshold in the ‘better’ ear and a tone at 10 dB below the admitted threshold in the ‘poorer’ ear simultaneously
postive stenger test
tells clinician that test results are inaccurate and patient is displaying nonorganic loss
tone in ‘poorer’ ear is masking
negative stenger test
patient responds to tone in the ‘better’ ear
tells clinician that the patient was admitting true behavioral thresholds
speech stenger test
known as modified stenger
done in the same manner as pure tone stenger using spondaic words
will identify the presence of a nonorganic loss and can approximate the true threshold of hearing
managing patients with nonorganic losses
approach patient about inconsistent results may help patient to start responding cooperatively (better to blame equipment or stated instructions than blame the patient)
one of biggest problems when working with patients is to determine what the true thresholds are
with children, it is not rooted in potential financial gain — audiologists should strive to determine the root cause of the child’s exaggerated responses possibly through referral to school psychologist
avoid vague judgements
do not assume the role of psychiatrist — while nonorganic cases and theri root cause can incite curiosity, it is not the role of the audiologist to delve into the psychological root
do not assume the role of the prosecutor — no matter how much evidence is present to suggest malingering, it is not the role of the audiologist to accuse the patient of malingering
malingering can only be identified without question if the patient admits to it
electroacoustic characteristics
measured and graphed over a frequency range of 125 to 10,000 Hz using a test box with a sound treated enclosure containing space for the hearing aid, frequency oscillator, and loudspeaker (responses compared to standardized norms)
standardized system for comparing hearing aids uses 2 cm3 coupler to connect a hearing aid to a measuring microphone (does not provide data relative to performance in the patient’s ear)
primary measures include: output sound pressure level (OSPL), acoustic gain, frequency response, distortion
output sound pressure level (OSPL)
the greatest sound pressure that can be made by a hearing aid regardless of the input level
also known as the saturation sound pressure level (SSPL) and maximum power output (MPO)
measured with the hearing aid volume full on and with an input signal of 90 dB SPL
acoustic gain
difference, in DB, between the input and output signals
gain (volume) control of the hearing aid is adjusted to a test reference level and 50 or 60 dB SPL is presented to the microphone
high frequency average (HFA): average gain at 1000, 1600, and 2500 Hz
frequency response
range of frequencies that a sound system can transmit and amplify is determined primarily by the limitations of the microphone, receiver, and earmold configuration
determined by measuring the reference test fain over a wide frequency range
a line is drawn parallel to the baseline that is 20 dB below a level showing the average gain at 1000, 1600, and 2500 Hz
— points of intersection are the frequency range
distortion
frequency: sound leaving the hearing aid differs in its frequency spectrum from the input signal
amplitude: differences in the relationships of the amplitudes of the input and output signals
harmonic: the percentage of distortion of the input signal
behind the ear hearing aids (BTEs)
suitable for mild to profound hearing losses
roughly 15% of the hearing aids dispensed
can be fit with custom earmolds
routinely used with children because the earmodls are easy to replace as their ears grow
receiver in the canal hearing aids (RICs)
much smaller than traditional BTEs comprising 70% of the hearing aids fit today
can be fit with an earmold or a flexible dome tip
suitable for mild to moderate losses — chance of acoustic feedback increases with greater loss
feedback: whistling sound caused by a cycle created by amplified sounds leaving the receiver and being re-amplified
in the ear hearing aids
hearing aid sits in the concha and external auditory canal with circuitry built directly into earmold
suitable for mild to severe losses
in the canal hearing aids
limited in power due to the size of the aids
may be suitable for mild to severe losses with modern feedback suppression circuits
completely in the canal hearing aids (CICs)
recessed within the external auditory canal
suitable for mild to moderate hearing losses
often the cosmetic advantages are not as great as the RIC
small size of the hearing aid means smaller batteries and reduced ability to couple to cell phones and assistive listening devices which may contribute to its lower market share
invisible in the canal hearing aids (IICs)
smallest style that can only be fit if the patient’s ear canal is large enough to accommodate the device electronics
same advantages and disadvantages as CICs
light driven hearing aids
non acoustic approach to sound amplification that uses light to transmit acoustic info to a transducer on the TM
digitally processed sound is projected as pulsed light onto a transducer that translates the signal into mechanical vibrations which directly vibrate the TM
suitable for mild to moderate losses
allows for greater frequency response, greater gain before feedback, and an unoccluded ear canal
appearance is the same as the RIC hearing aid
CROS hearing aids
contralateral routing of offside signal systems are used for patients with an unaidable hearing loss in one ear
microphone is mounted on the side with the hearing loss and the signal is wirelessly transmitted to a receiver worn on the other era
sounds from the ‘bad’ ear are sent to the ‘good’ ear
canal of the normal hearing ear is left as unoccluded as possible to allow unaided sounds to travel through normal sound transmission
BiCROS hearing aid
works in the same way as a CROS system except the ‘better’ ear has an aidable hearing loss
‘better’ ear also recipes amplification
bone conduction hearing aids
used for patients with conductive hearing losses and otological conditions that prevent the use of air conduction and amplification systems
otological conditions may include persistent or recurrent ear drainage or ear canal abnormalities
vibrating receiver transducer is placed against the mastoid bone stimulating both cochleae and as a result, tru binaural hearing loss is not possible although bilateral BC hearing aids are beneficial
implantable hearing devices
used when nonsurgical options do not provide benefit for the type or degree of hearing loss that a patient has
implantable bone conduction devices
used for patients with conductive hearing losses that cannot use more traditional air conduction amplification due to ear drainage or malformation
snap or magnetic plate attachment is surgically mounted in the mastoid bone
once the incision heals, a bone conduction vibrator snaps on the attachment or magnetically connects over the mastoid
bone conduction stimulation routes sounds to both cochleae
provides good sound quality and elimination of feedback
FDA approved for individuals 5 years old and up
middle ear implants
received FDA clearance in 2000 for individuals 18 years of age or older
eliminates occlusion and acoustic feedback but comes with high costs and potential surgical risks and no significant cosmetic advantage given some of the smaller more traditional hearing instruments
three component
external audio processor: transmits sound across the skin
implanted receiver: transmits the converted electrical signal to a transducer
transducer: mounted on the ossicular chain
cochlear implants
allows for direct stimulation of auditory nerve in absence of viable hair cell function
internal receiver under skin behind pinna contains wire electrodes that are placed in scala tympani within the cochlea
microphone picks up sound and feed electrical impulses to speech processor and sends impulses to implanted electrode array
for pediatric candidates, FDA recommends implanting not done before 12 months of age
degree of success hinges on variety of personal and support factors, but generally adults with post linguistic deafness of shorter duration and children implanted before 2 years of age attain the highest levels of success
pediatric team may include otologic surgeon, the child’s pediatrician, psychologist, audiologist, SLP and auditory rehab therapist
auditory brain stem implants
bypasses the cochlea and first order neurons to directly stimulate the cochlear nuclei
done for patients with no cochlear nerve to stimulate such as in cases of bilateral acoustic neuromas
can be fit on children as young as 18 months of age
implanted electrode is coupled through a transcutaneous magnetic connector to an external sound processor
Carhart’s Goals for Hearing Aid Selection
provide restoration of adequate sensitivity for speech and environmental sounds too faint to hear without hearing aids
provide a restoration, retention, or acquisition of the clarity of speech and other sounds within ordinary, relatively quiet environments
achieve the same when these sounds occur in noisier environments
ensure that higher intensity sounds are not amplified to an intolerable level
verification of hearing aid performance for adults
measuring how well the hearing aids are working in comparison to prescribed fitting specifications
prove microphone measures reflect the acoustic characteristics of the hearing aid and the natural individual resonance of the ear itself and interactions among these effects
assess audibility and hearing aid maximum output to prevent over amplification
sound field speech recognition measures provide insight as to how well the individual is processing incoming sounds
validation of hearing aid performance for adults
measures the patient’s perception of benefits of hearing aid
can be done through questionnaires or other self assessment measures
verification of hearing aid performance for children
children often will not sit through all desired probe microphone measures
if a single aided probe microphone measure can be attained, the difference between its measure and that obtained from a 2 cm3 hearing aid analyzer (the real ear/coupler difference) can be determined to give insight into the expected aided performance
complaints associated with balance disorders
vertigo (spinning sensation)
lightheadedness
disorientation
imbalance
gait disturbances
decreased gaze stability
nystagmus
rapid, oscillatory eye movement, usually side to side
tests that elicit nystagmus can shed light on the origins of a patient’s dizziness complaints
Caloric Testing
stimulates the labyrinth of the inner ear by flushing warm or cold water or air against the TM
cold water/air: normal vestibular function — fast nystagmus away from stimulated ear and slow eye movement back
warm water/air: normal vestibular function — fast nystagmus towards the stimulated ear and slow eye movement back
COWS acronym: cold — opposite; warm — same
Electronystagmography (ENG)
uses strategically placed electrodes around the eyes
measures the electrically potential changes in eye movement during caloric testing
replaced with videonystagmography
Videonystagmography (VNG)
uses infrared video system with tiny cameras within a set of goggles to track eye movement during vestibular testing
goggles are dark which makes the infrared light invisible
responses are recorded and can be viewed later
allows for greater objectivity when measuring nystagmus
Video Head Impulse Test (vHIT)
uses infrared video goggles to provide measure of the vestibulo-ocular reflex in response to head movement
the vHIT system’s accelerometer quickly measures head movement while the camera records eye movement
Rotary Chair Testing
originally done as a subjective test but can now be performed objectively using computers
patient sits in a chair that mechanically rotates
infrared goggles measure the oscillatory movements of nystagmus after the chair is rotated
determines if the balance dysfunction is caused by deficits in the vestibular or neurological system
Computerized Dynamic Posturography (CDP)
assesses the ability to coordinate movement by measuring vestibulospinal reflexes
measures patient’s postural compensation while patient stands on a platform that shifts from various angles
quantitative assessment of upright balance
different test protocols can provide various insights
information on the patient’s ability to complete a range of daily life tasks
localizing the cause of the balance disorder
vestibular evoked myogenic potential (VEMP)
sound evoked muscle reflex that is thought to be generated from acoustic stimulation of the saccule (one of the vestibular end organs that sense linear acceleration)
the reflex may help to stabilize the head in response to unpredictable movements
Goals of Vestibular Treatment
to decrease the frequency, intensity, and duration of dizziness episodes
to improve an individual’s functional balance
to decrease the severity of related symptoms of nausea, headache, and lightheadedness
to improve the individual’s performance of daily activities
to develop compensation strategies for coping with disequilibrium, dizziness, and accompanying anxiety
Vestibular Rehabilitation
audiologists and physical therapists can provide vestibular rehabilitations
forms:
habituation/adaptation exercises
canalith repositioning
balance retraining
habituation/adaptation exercises
the brain is capable of retraining its response to sudden movements
patients perform specific instructed movements or assume specific positions to provoke dizziness and are instructed to repeat these movements until the brain is accustomed to the response
canalith repositioning
the patient’s head is moved in a sequence of positions to reposition the otoconia within the semicircular canals
effective treatment for many individuals suffering from benign positional vertigo
BPPV
otolith organs: saccule and utricle
otoconia: small crystals of calcium carbonate that are normally located in the utricle (aka canaliths or otoliths)
dix-hallpike maneuver diagnoses (it is nystagmus present or not, which side)
epley maneuver treats it (repositions the crystals)
balance retraining
improves the coordination of muscle responses
enhances the integration of sensory information from the eyes, ears, and muscle receptors controlling proprioception
tinnitus
may be described as ringing, roaring, hissing, whistling, chirping, rustling, clicking, buzzing, or another similar descriptor
around 20 million people deal with burdensome tinnitus on a routine basis
30% of people with tinnitus report it as a significant problem in their lives
approx. 90 million people may experience occasional tinnitus with no other ear disease or active pathology
subjective tinnitus
only the individual reporting tinnitus can hear it
more frequently seen
objective tinnitus (somatosound)
due to sounds generated by blood vessels or muscles near the ear
audible to individuals other than the person reporting tinnitus (i.e. on examination when listening with a stethoscope)
less common form of tinnitus
managing tinnitus
includes consultation with other professionals
a symptom of any number of pathologies (correction of medically treatable hearing pathology will cure it)
hearing aids bring normal sounds of life into ear at an appropriate level to decrease tinnitus
no cure for tinnitus
wearable tinnitus masking units — worn like hearing aid, masker creates a band of noise that surrounds the frequency of tinnitus; marginal success
tinnitus habituation — reduce (not mask) the perceived intensity of tinnitus along with detailed education and counseling to help reduce negative emotional reactions to tinnitus are frequency successful
hyperacusis
reduced tolerance to loud sounds
threshold of discomfort may be as low as 20 to 25 dB SPL for low frequency sounds decreasing to little as 5 dB SL for sounds greater than 10,000 Hz
negative reactions are dependent upon the spectrum and intensity of the sound not on the sound’s meaning or context of occurrence
many with tinnitus also have hyperacusis and consider it equally or more disturbing than the tinnitus
rehabilitation may be successful through a series of desensitization exercises over a protracted time
misophonia (aka soft sound sensitivity syndrome)
negative reactions are unrelated to the sound’s intensity but rather to sounds with specific patterns or meaning
trigger sounds are most often created by another person or animal and are frequently oral or eating related sounds, but can also be repetitive sounds such as keyboard typing, clicking of a pen, finger tapping, etc.
eitology is unknown and hearing is most often normal
treatment may include masking of the offending sound, avoiding known trigger situations when possible, or avoiding persons who trigger negative responses when not tested