what is data drop?

when parts of the anatomy are so overexposed that they don’t show up on the final image

2
New cards

what is detector saturation?

data drop that involves specific areas or regions of the detector

3
New cards

what is electronic masking?

also known as “cropping,” a post-processing function that removes undesirable information from a data set to improve image quality; has no effect on resolution

4
New cards

what is electronic annotation?

post-processing function that labels the image conditions; pt position, pt info, etc

5
New cards

what is dose creep?

when radiologists overtime gradually increase exposure techniques to decrease image noise

6
New cards

what is the variable kVp formula?

(2*Part cm) + 30 kVp= new kVp

7
New cards

what is diagnostic yield?

the amount of clinically significant information produced

8
New cards

what is diagnostic efficacy?

the faithful representation of the patient on a medical radiograph; also called image fidelity

9
New cards

what are LCR artifacts?

things that can be seen on images such as clothing artifacts, bandaged, tattoos, etc

10
New cards

list examples of digital artifacts

phantom images, scratches/tears, light spots, white line, dropout artifacts, fogging, quantam mottle, laser film transport artifacts, histogram analysis error, non-parallel collimation, poor grid alignment, random electronic artifacts

11
New cards

what causes detector saturation and data drop?

extreme overexposure

12
New cards

what is optimal kVp?

used by fixed kVp systems, the max kVp level that will produce images with appropriate contrast consistently in acceptance limits

13
New cards

what is the fixed kVp system?

double or half the mAs for every 5cm of subject thickness; kVp remains the same; better for digital IRs

14
New cards

what is the only step of the process of establishing a technique system that you need to know?

test exposure are first done using a phantom

15
New cards

what does a DI value of +2 mean?

exposure was 50% above recommended target

16
New cards

what does a DI value of -2 mean?

exposure was 50% below recommended target

17
New cards

what are DI values of +3 or greater considered?

an ALARA violation

18
New cards

what is photon starvation?

underexposure to the detector

19
New cards

what are the 6 tenets of radiologic images?

  1. legal document

  2. pictorial record

  3. single moment in patient’s medical timeline

  4. accurate and optimal techniques used

  5. department routines and procedures are followed

  6. ALARA compliant


20
New cards

how can you correct data drop?

post-processing and pixel recovery, collimation, tissue bolusing, compensating filtration

21
New cards

what is distortion?

the misrepresentation of the size and/or shape of the anatomical part being imaged

22
New cards

what is size distortion?

magnification; minification is impossible due to the divergent properties of x-ray photons

23
New cards

what is the most important thing to remember in regards to setting kVp for digital systems?

when higher kVp is used, width of the acquired date becomes narrower, which is desirable because it displays more anatomical data while reducing patient dose

24
New cards

what causes distortion?

it’s always present due to the divergent x-ray photons

25
New cards

how does SID affect magnification?

they’re indirectly proportional to each other

26
New cards

how does OID affect magnification?

they are directly proportional to each other

27
New cards

what’s the most effective way to control magnification?

maximize SID and minimize OID

28
New cards

how do you calculate magnification?

M= SID/SOD

29
New cards

SID = ?

SOD + OID

30
New cards

how do you find the object size?

O= I/M

31
New cards

what is shape distortion?

the misrepresentation by unequal magnification across the dimension of the object

32
New cards

what are the two types of shape distortion?

elongation and foreshortening

33
New cards

what is elongation?

when the object projects to be longer than it really is

34
New cards

what is foreshortening?

when the object projects to be shorter than it really is

35
New cards

what causes elongation?

when the tube or IR is improperly aligned

36
New cards

what causes foreshortening

when the part is improperly aligned

37
New cards

what does tube angulation cause?

elongation

38
New cards

why does shape distortion occur?

because structures lie normally at different levels within the body and because of the divergence of the x ray beam

39
New cards

what is informatics?

organizational theory all motivated by the need for new solutions to enhance the quality and safety of patient care

40
New cards

what does BMI stand for?

biomedical informatics

41
New cards

what is BMI?

an interdisciplinary field of platforms used for medical purposes such as patient care and clinical research

42
New cards

name the 5 subspecialities of BMI

  1. translational

  2. clinical research

  3. clinical

  4. consumer health

  5. public health


43
New cards

name the 4 BMI platforms

  1. PACS

  2. HIS

  3. RIS

  4. EMR/EHR


44
New cards

what does PACS stand for?

picture archiving and communication system

45
New cards

what is PACS?

a networked group of computers, servers, and archives to manage digital images that are configured in a manner that facilitates storing, retrieving, and distributing medical images

46
New cards

what is clinical informatics?

utilizes data and information technology to deliver healthcare services

47
New cards

what does HIS and RIS stand for?

hospital/radiology information systems

48
New cards

what is HIS?

database containing all patient medical record information except for radiology

49
New cards

what is RIS?

radiology specific database

50
New cards

what does EHR/EMR stand for?

electronic health/medical record

51
New cards

what is EMR/EHR?

an electronic version of an individual patient’s collection of medical documents; took place of paper medical chart

52
New cards

what does DICOM stand for?

digital imaging and communication in medicine

53
New cards

what is dicom?

standard format for communicating imaging files around the world

54
New cards

what are the main components of informatics platforms and applications?

hardware and software

55
New cards

what is hardware?

mainframe, CPU, memory, input devices, output devices, and the bus (connects motherboard components and CPU/allows for data transfer)

56
New cards

what is software?

computer programs, applications, and operating systems

57
New cards

what is LAN?

network common for serving computers in small geographical areas

58
New cards

what is WAN?

2 or mORE LANs serving a large geographical network

59
New cards

what is intranet?

connections inside of an organization/controlled by a single authority (ex. inside of a specific hospital)

60
New cards

what is extranet?

private network controlled by organization that creates connections outside of it (ex. hospital supply manufacturers, laundry, etc.)

61
New cards

what is cloud computing?

allows for virtual access of shared resources/storage while maintaining location and device independence

62
New cards

how many bits=1 byte?

8

63
New cards

what is the formula for determining image file size?

XY (B/8)

64
New cards

what is a hardcopy display?

images on film, produced using laser printers and dry processors

65
New cards

what is a softcopy display?

flat screen monitors

66
New cards

how long are images typically archived for?

5-7yrs; pediatric and litigation stored indefinitely

67
New cards

what is a typical storage requirement?

terabyte storage; 1Tb=10,000Gb=10,000,000Mb

68
New cards

what is the relationship between image resolution and data size?

directly proportional

69
New cards

what is lossless compression?

it allows all of the original information in the image to be retained the loss of any information

70
New cards

what is lossy compression?

it loses data once the image is compressed and the uncompressed, which can cause a loss of resolution (bad)

71
New cards

what are examples of short term storage?

local hard drive, PACS server and redundant display of independent discs (RAID)

72
New cards

what are examples of long term storage?

jukebox of discs or tapes

73
New cards

what are examples of short term storage?

jukebox of discs or tapes

74
New cards

what does HIPPA stand for?

health insurance portability and accountability act of 1996

75
New cards

what is a network?

allows computer to exchange data and share resources

76
New cards

what is bandwidth?

describes how much data can be moved, measured in bps