1/27
Vocabulary practice flashcards covering structural analysis, prestressed concrete mechanics, steel beam and column design formulas, and conceptual framing principles for the ARC311 Test 3.
Simply Supported Beam Maximum Moment (Uniform Load)
The peak bending moment occurring at midspan under a uniform load w, calculated as +8wl2.
Simply Supported Beam Maximum Deflection (Uniform Load)
The maximum downward deflection under a uniform load w, equal to 384EI5wl4.
Fixed-Fixed Beam Maximum Moments (Uniform Load)
The extreme bending moments under a uniform load w, resulting in −12wl2 at the ends and +24wl2 at midspan.
Fixed-Fixed Beam Maximum Deflection (Uniform Load)
The maximum downward deflection occurring under a uniform load w, calculated as 384EIwl4, which is 5 times smaller than that of an equivalent simply supported beam.
Transfer Stress Limits (Prestressed Concrete)
Allowable stress thresholds right after tendon release when concrete is young: compression is limited to 0.6fci′ and tension is limited to 3\root\relax\blank\blank{f'_{ci}} (with f′ in psi, converted to ksi by dividing by 1000).
Service Stress Limits (Prestressed Concrete)
Allowable long-term stress thresholds under full loading: compression is limited to 0.45fc′ and tension is limited to 7.5\root\relax\blank\blank{f'_c} (with f′ in psi, converted to ksi by dividing by 1000).
Transfer Condition
The initial design state in prestressed concrete occurring immediately after tendons are released, characterized by young concrete strength (fci′), initial prestress force before losses (Pi), and self-weight only (no live load).
Service Condition
The long-term operating state of prestressed concrete under full service load (self-weight + dead load + live load), utilizing full concrete strength (fc′) and effective prestress force after creep, shrinkage, and relaxation losses (Pc).
Prestress Bending Stress
The bending stress produced by tendon eccentricity, calculated as f=IP⋅e⋅y, which produces tension at the top fiber and compression at the bottom fiber (opposing the load-induced bending).
Prestress Axial Stress
The uniform compressive stress generated along a prestressed concrete cross-section, calculated as f=−AP.
Balanced Load Design
A design method where tendon profile and force are chosen to counteract the bending moment induced by a specified portion of gravity loads (self + dead + a percentage of live), solving for required post-loss prestress force as Pc=eM.
Plastic Section Modulus (Zx)
The cross-sectional property representing a steel beam's fully yielded moment resistance, used in LRFD sizing such that Zreq=FallowMu.
Euler Buckling Equation
The fundamental formula predicting the critical compressive buckling load of an elastic column: Pcr=(KL)2π2EI, which increases with stiffness/moment of inertia (I) and decreases with the square of the effective length (KL).
Effective Length Factor (K)
A coefficient modifying actual column length L based on support fixity: theoretical (design) values are 0.5 (0.65) for fixed-fixed, 0.7 (0.80) for fixed-pinned, 1.0 (1.0) for pinned-pinned, and 2.0 (2.1) for fixed-free (cantilever).
Short Columns vs. Long Columns
Short columns fail primarily by crushing where compressive capacity is directly proportional to cross-sectional area (P∝Area), whereas long columns fail by buckling where capacity is governed by length (P∝L21).
Double-Height Atrium Effect
The architectural scenario where eliminating an intermediate floor unbraced length doubles (2L), causing a column's Euler buckling capacity to decrease by approximately 4× unless braced at mid-height or sized significantly larger.
Dead Load (D)
The permanent, stationary weight of the building structure itself along with fixed architectural, mechanical, and non-structural elements.
Live Load (L)
Temporary or movable gravity loads imposed on a structure during occupancy, including people, furnishings, and equipment.
Reinforced Concrete Depth Rule of Thumb
An empirical sizing guideline for reinforced concrete beams estimating depth as approximately d≈20L.
Pre-tensioned Concrete
Prestressed concrete where internal high-strength tendons are stressed against external bulkheads before concrete is placed around them.
Post-tensioned Concrete
Prestressed concrete where tendons are placed inside ducts and tensioned against the member after the concrete has hardened and cured.
Draped Tendons
Tendons placed in a curved or draped profile across a span to ensure the prestress moment diagram mimics the applied load moment diagram, eliminating adverse tensile stresses at top fibers near the supports.
Beam Web Openings
Penetrations for mechanical ducts that should be located at beam midspan near mid-depth, where shear is lowest (approaching zero) and flanges carry nearly all the bending moment.
Transfer Girder
A large structural beam utilized when upper-floor columns are discontinued or do not align vertically with lower framing, rerouting their concentrated loads into adjacent support columns.
Steel Carbon Content
The proportion of carbon alloyed into iron to produce structural steel, typically ranging from 0.02% to 1.7%.
Castellated Beam
A steel beam fabricated by cutting a standard wide-flange section along a zig-zag pattern and welding it offset, creating openings to increase overall depth and moment of inertia (I) without adding weight.
Lateral-Torsional Buckling
An instability failure mode where an unbraced beam twists and deflects laterally under bending loads before reaching its full plastic capacity (Mp); prevented by providing continuous lateral bracing.
Web Stiffeners
Plates welded vertically to the web of steel beams or plate girders to prevent localized web buckling and handle high shear forces or concentrated point loads.