ARC311 Test 3 Study Outline

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/27

flashcard set

Earn XP

Description and Tags

Vocabulary practice flashcards covering structural analysis, prestressed concrete mechanics, steel beam and column design formulas, and conceptual framing principles for the ARC311 Test 3.

28 Terms

1
New cards

Simply Supported Beam Maximum Moment (Uniform Load)

The peak bending moment occurring at midspan under a uniform load ww, calculated as +wl28+\frac{wl^2}{8}.

2
New cards

Simply Supported Beam Maximum Deflection (Uniform Load)

The maximum downward deflection under a uniform load ww, equal to 5wl4384EI\frac{5wl^4}{384EI}.

3
New cards

Fixed-Fixed Beam Maximum Moments (Uniform Load)

The extreme bending moments under a uniform load ww, resulting in −wl212-\frac{wl^2}{12} at the ends and +wl224+\frac{wl^2}{24} at midspan.

4
New cards

Fixed-Fixed Beam Maximum Deflection (Uniform Load)

The maximum downward deflection occurring under a uniform load ww, calculated as wl4384EI\frac{wl^4}{384EI}, which is 5 times smaller than that of an equivalent simply supported beam.

5
New cards

Transfer Stress Limits (Prestressed Concrete)

Allowable stress thresholds right after tendon release when concrete is young: compression is limited to 0.6fci′0.6 f'_{ci} and tension is limited to 3\root\relax\blank\blank{f'_{ci}} (with f′f' in psi\text{psi}, converted to ksi\text{ksi} by dividing by 10001000).

6
New cards

Service Stress Limits (Prestressed Concrete)

Allowable long-term stress thresholds under full loading: compression is limited to 0.45fc′0.45 f'_c and tension is limited to 7.5\root\relax\blank\blank{f'_c} (with f′f' in psi\text{psi}, converted to ksi\text{ksi} by dividing by 10001000).

7
New cards

Transfer Condition

The initial design state in prestressed concrete occurring immediately after tendons are released, characterized by young concrete strength (fci′f'_{ci}), initial prestress force before losses (PiP_i), and self-weight only (no live load).

8
New cards

Service Condition

The long-term operating state of prestressed concrete under full service load (self-weight + dead load + live load), utilizing full concrete strength (fc′f'_c) and effective prestress force after creep, shrinkage, and relaxation losses (PcP_c).

9
New cards

Prestress Bending Stress

The bending stress produced by tendon eccentricity, calculated as f=P⋅e⋅yIf = \frac{P \cdot e \cdot y}{I}, which produces tension at the top fiber and compression at the bottom fiber (opposing the load-induced bending).

10
New cards

Prestress Axial Stress

The uniform compressive stress generated along a prestressed concrete cross-section, calculated as f=−PAf = -\frac{P}{A}.

11
New cards

Balanced Load Design

A design method where tendon profile and force are chosen to counteract the bending moment induced by a specified portion of gravity loads (self + dead + a percentage of live), solving for required post-loss prestress force as Pc=MeP_c = \frac{M}{e}.

12
New cards

Plastic Section Modulus (ZxZ_x)

The cross-sectional property representing a steel beam's fully yielded moment resistance, used in LRFD sizing such that Zreq=MuFallowZ_{\text{req}} = \frac{M_u}{F_{\text{allow}}}.

13
New cards

Euler Buckling Equation

The fundamental formula predicting the critical compressive buckling load of an elastic column: Pcr=π2EI(KL)2P_{cr} = \frac{\pi^2 EI}{(KL)^2}, which increases with stiffness/moment of inertia (II) and decreases with the square of the effective length (KLKL).

14
New cards

Effective Length Factor (KK)

A coefficient modifying actual column length LL based on support fixity: theoretical (design) values are 0.50.5 (0.650.65) for fixed-fixed, 0.70.7 (0.800.80) for fixed-pinned, 1.01.0 (1.01.0) for pinned-pinned, and 2.02.0 (2.12.1) for fixed-free (cantilever).

15
New cards

Short Columns vs. Long Columns

Short columns fail primarily by crushing where compressive capacity is directly proportional to cross-sectional area (P∝AreaP \propto \text{Area}), whereas long columns fail by buckling where capacity is governed by length (P∝1L2P \propto \frac{1}{L^2}).

16
New cards

Double-Height Atrium Effect

The architectural scenario where eliminating an intermediate floor unbraced length doubles (2L2L), causing a column's Euler buckling capacity to decrease by approximately 4×4\times unless braced at mid-height or sized significantly larger.

17
New cards

Dead Load (DD)

The permanent, stationary weight of the building structure itself along with fixed architectural, mechanical, and non-structural elements.

18
New cards

Live Load (LL)

Temporary or movable gravity loads imposed on a structure during occupancy, including people, furnishings, and equipment.

19
New cards

Reinforced Concrete Depth Rule of Thumb

An empirical sizing guideline for reinforced concrete beams estimating depth as approximately d≈L20d \approx \frac{L}{20}.

20
New cards

Pre-tensioned Concrete

Prestressed concrete where internal high-strength tendons are stressed against external bulkheads before concrete is placed around them.

21
New cards

Post-tensioned Concrete

Prestressed concrete where tendons are placed inside ducts and tensioned against the member after the concrete has hardened and cured.

22
New cards

Draped Tendons

Tendons placed in a curved or draped profile across a span to ensure the prestress moment diagram mimics the applied load moment diagram, eliminating adverse tensile stresses at top fibers near the supports.

23
New cards

Beam Web Openings

Penetrations for mechanical ducts that should be located at beam midspan near mid-depth, where shear is lowest (approaching zero) and flanges carry nearly all the bending moment.

24
New cards

Transfer Girder

A large structural beam utilized when upper-floor columns are discontinued or do not align vertically with lower framing, rerouting their concentrated loads into adjacent support columns.

25
New cards

Steel Carbon Content

The proportion of carbon alloyed into iron to produce structural steel, typically ranging from 0.02%0.02\% to 1.7%1.7\%.

26
New cards

Castellated Beam

A steel beam fabricated by cutting a standard wide-flange section along a zig-zag pattern and welding it offset, creating openings to increase overall depth and moment of inertia (II) without adding weight.

27
New cards

Lateral-Torsional Buckling

An instability failure mode where an unbraced beam twists and deflects laterally under bending loads before reaching its full plastic capacity (MpM_p); prevented by providing continuous lateral bracing.

28
New cards

Web Stiffeners

Plates welded vertically to the web of steel beams or plate girders to prevent localized web buckling and handle high shear forces or concentrated point loads.