digital radiography

0.0(0)
Studied by 13 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/78

encourage image

There's no tags or description

Looks like no tags are added yet.

79 Terms

1
New cards

what is the basic sequence of direct conversion?

x-rays → electronic signal → digital

2
New cards

what is the basic sequence of indirect conversion?

x-rays → light → electronic signal → digital

3
New cards

between direct conversion and indirect conversion, which system is used more commonly?

indirect conversion

4
New cards

between direct conversion and indirect conversion, which system uses a scintillator?

indirect conversion

5
New cards

what is the main function of scintillation?

converts x-rays into light

6
New cards

what are the two types of systems used for indirect conversion?

charge-coupled device (CCD) and thin film transistor (TFT)

7
New cards

which layer(s) consist of the charge-coupled device (CCD)?

scintillation

8
New cards

which layer(s) consist of the thin film transistor (TFT)?

scintillation and photodiode

9
New cards

what is the thin film transistor (TFT) most commonly used for?

angiography and fluoroscopy

10
New cards

what are two advantages of using indirect conversion?

cost-effective and easier to repair and replace parts

11
New cards

what is a disadvantage of using indirect conversion?

extra conversion reduces spatial resolution

12
New cards

what material is a charge-coupled device (CCD) made of?

silicon

13
New cards

what are the 3 characteristics of a charge-coupled device (CCD)?

  • very sensitive to light (from scintillator)

  • wide dynamic range (many shades of gray)

  • small size


14
New cards

what is fill factor?

percentage of the actual pixel size that is sensitive to the x-rays

15
New cards

as fill factor gets larger, resolution increases or decreases?

increases

16
New cards

the higher the fill factor, the _________ the resolution

higher

17
New cards

what is the main function of a storage capacitor?

temporarily holds the charge

18
New cards

which imaging procedures is the direct method most commonly used in?

mammography and angiography

19
New cards

which layer(s) are included in the direct method?

photoconductor (amorphous selenium), thin film transistor (TFT), analog-to-digital converter

20
New cards

what are two advantages of using direct conversion?

higher spatial resolution and less steps

21
New cards

what are digital images?

a matrix of pixel values

22
New cards

what produces a small signal and appears white on a radiograph?

bone

23
New cards

what produces a medium signal and appears grey on a radiograph?

soft tissue

24
New cards

what produces a large signal and appears black on a radiograph?

air

25
New cards

is bone radiopaque or radiolucent?

radiopaque

26
New cards

is air radiopaque or radiolucent?

radiolucent

27
New cards

what is a pixel?

smallest visible unit of a digital image that determines spatial detail of an x-ray image

28
New cards

what is a bit?

  • smallest unit of digital data

  • how many brightness values each pixel can have

  • how many shades of gray it can take on


29
New cards

what is bit depth?

pixel’s range of possible shades of gray

30
New cards

as bit depth increases, contrast resolution…

increases

31
New cards

high contrast resolution means more or less shades of gray?

more

32
New cards

as pixels increase, matrix…

increases

33
New cards

what is resolution?

detail of structure on the image

34
New cards

as pixels increases, resolution…

increases

35
New cards

true or false: no DR imaging system can resolve an object smaller than the pixel size

true

36
New cards

what is an image matrix?

layout of rows and columns of pixels

37
New cards

as matrix size increases, spatial resolution…

increases

38
New cards

what is spatial frequency?

describes how often image details repeat per unit distance in an image

39
New cards

what is spatial frequency measured in?

line pairs per mm

40
New cards

when imaging larger structures, would we want an increase or decrease in spatial frequency?

decrease

41
New cards

when imaging smaller structures, would we want an increase or decrease in spatial frequency?

increase

42
New cards

what does a modulation transfer function help describe?

how well an imaging system preserves detail or contrast at different spatial frequencies

43
New cards

what does a modulation transfer function allow an imaging system to display?

objects of different sizes onto an image

44
New cards

what does a modulation transfer function (MTF) of 0 indicate?

no information is transferred

45
New cards

what does a modulation transfer function (MTF) of 1 indicate?

faithful representation of the object

46
New cards

what is a dynamic range?

range of values over which a system can respond

47
New cards

what is a dynamic range also known as?

gray scale range or number of shades of gray

48
New cards

does an abdomen have a lower or higher dynamic range?

higher

49
New cards

higher dynamic range → [less/more] shades of gray → [low/high] contrast → [less/more] contrast resolution → [narrow/wide] latitude

more, low, more, wide

50
New cards

do extremities have a lower or higher dynamic range?

lower

51
New cards

smaller dynamic range → [less/more] shades of gray → [low/high] contrast → [less/more] contrast resolution → [narrow/wide] latitude

less, high, less, narrow

52
New cards

what is contrast resolution?

an imaging system’s ability to distinguish between similar tissues

53
New cards

list the 6 image quality factors

brightness, contrast, resolution, distortion, exposure index, noise

54
New cards

what is brightness?

intensity of light that represents the individual pixels in the image on the monitor

55
New cards

brightness replaces…

density

56
New cards

is the term ‘density’ used in relation to film or digital?

film

57
New cards

is the term ‘brightness’ used in relation to film or digital?

digital

58
New cards

what is contrast?

difference in brightness between light and dark areas of an image

59
New cards

what are the three methods used to control scatter radiation?

  • close collimation

  • usage of grids

  • optimal kV


60
New cards

in film imaging, what determines spatial resolution?

focal spot size

61
New cards

in digital radiography imaging, what determines spatial resolution?

pixel size

62
New cards

what is noise?

a random disturbance that obscures or reduces clarity of the image

63
New cards

what is clarity?

visibility of detail

64
New cards

what is the signal to noise ratio (SNR)?

the ratio of useful x-ray signal to unwanted noise in an image

65
New cards

the number of x-ray photons that strike the detector is considered the…

mAs

66
New cards

besides noise, what is another factor that affects the final image?

signal

67
New cards

as noise increases, contrast resolution…

decreases

68
New cards

would a low or high signal to noise ratio (SNR) be more desirable?

high

69
New cards

what does a low signal to noise ratio (SNR) demonstrate on a radiograph?

a grainy image

70
New cards

as mAs is increased, the signal to noise ratio (SNR) is…

increased

71
New cards

what two things does low signal to noise ratio (SNR) cause?

scatter radiation and electronic noise

72
New cards

what is electronic noise?

inherent noise in the electronic system, power fluctuations, and non-uniformity of the detector

73
New cards

can we control electronic noise?

no

74
New cards

with direct digital radiography (DDR), what is the patient dose reduction percentage range?

20-50%

75
New cards

with indirect digital radiography (DDR) from film, what is the patient dose reduction percentage range?

30-50%

76
New cards

what is detective quantum efficiency (DQE)?

the ability of a material to absorb x-ray energy

77
New cards

as detective quantum efficiency (DQE) increases, patient dose…

decreases

78
New cards

which electronic conductor has the highest detective quantum efficiency (DQE)?

selenium

79
New cards

what is the minimum percentage of the imaging plate that should be exposed to x-rays to ensure an accurate exposure indicator reading?

30%