What is the fire-risk classification of N and CO2?

nonflammable

2
New cards

T/F, O2 is flammable

False

3
New cards

By what means is oxygen for medical use in a hospital most commonly produced?

Fractional distalation

4
New cards

What is the U.S. Food and Drug Administration (FDA) purity standard for O2?

99%

5
New cards

Which of the following methods of producing O2 is commonly used in the home care setting?

physical separation (sieve)

6
New cards

Large hospital air compressor systems must be capable of maintaining 50 pounds per square inch gauge (psig) at what flows?

100L/min

7
New cards

T/F, helium is heavier than air

False

8
New cards

What key property of He makes it useful as a therapeutic gas?

Low density

9
New cards

Which of the following gases is used to treat conditions causing hypoxic respiratory failure?

NO

10
New cards

Compressed gas cylinders are manufactured from which of the following?

Seamless steel

11
New cards

Department of Transportation (DOT) regulations require compressed gas cylinders to be hydrostatically tested for leaks and expansion every how often?

5-10 years

12
New cards

During inspection of the shoulder of a compressed gas cylinder, you note a plus sign (+) next to the test date. This indicates what about the cylinder?

It can be filled to 10% above its service pressure.

13
New cards

According to the U.S. Department of Commerce, a gas cylinder that is color coded blue should contain what gas

N2O

14
New cards

According to the National Institute of Standards and Technology of the U.S. Department of Commerce, a gas cylinder that is color-coded brown and green should contain what gas

O2-He mixture

15
New cards

In clinical practice, how is a positive identification made of the contents of a medical gas cylinder?

Reading the cylinder label

16
New cards

Which of the following mechanisms do all compressed gas cylinders use to avoid excessively high buildup of cylinder pressure?

pressure-relief mechanism on the valve stem

17
New cards

Cylinders of liquid gases are filled according to what specification?

filling density

18
New cards

The measured pressure in a liquid-filled cylinder is equivalent to what

the pressure of the surface vapor at any given temperature

19
New cards

When full, a gas cylinder registers a pressure of 2200 psig. After a few hours of use, the pressure gauge reads 550 psig. The cylinder is now how full?

One fourth

20
New cards

What is the usual method of monitoring the remaining contents in a gas-filled cylinder?

read the pressure gauge

21
New cards

To accurately determine the remaining contents of a liquid-filled CO2 cylinder, what would you do?

weigh the contents of the cylinder

22
New cards

One cubic foot of any gas is equivalent to how many liters of gas?

28.30

23
New cards

What cylinder factor is used to compute the duration of flow for a 244 cu/ft (H/K) O2 or air cylinder?

3.14

24
New cards

What cylinder factor is used to compute the duration of flow for a 22 cu/ft O2 or air E cylinder?

0.28

25
New cards

The gauge on an H cylinder of O2 reads 2000 psig. About how long would the contents of this cylinder last, until completely empty, at a flow of 6 L/min?

17 hours 30 minutes

26
New cards

The gauge on an E cylinder of O2 reads 800 psig. About how long would the contents of this cylinder last, until completely empty, at a flow of 3 L/min?

1 hour 15 minutes

27
New cards

ou are planning a patient transport that will take about 1 hours. The patient requires manual ventilation with 10 L/min of O2. What is the minimum number of full E cylinders you would take with you?

2

28
New cards

Structural requirements for the central piping systems that are used in hospitals to distribute gases are established by whom?

National Fire Protection Association (NFPA)

29
New cards

The pressure of O2 or air in a bulk supply system is reduced to what standard working pressure?

50 psig

30
New cards

What is the primary purpose of indexed connector systems?

to prevent inadvertent misconnections between equipment

31
New cards

What is the indexed safety system for threaded high-pressure connections between large compressed gas cylinders and their attachments?

American Standard Safety System (ASSS)

32
New cards

Which of the following is false about ASSS standards?

They provide a separate connector for all gases.

33
New cards

Which of the following statements is FALSE about PISS standards?

The exact positions of pins and pinholes do not vary for each gas.

34
New cards

What is the PISS index hole position for O2?

2 and 5

35
New cards

What safety system is designed to prevent accidental interchanging among low-pressure (less than 200 psig) connectors such as those found on flowmeters and ventilators?

DISS

36
New cards

What device is used to reduce the pressure and control the flow of a compressed medical gas?

regulator

37
New cards

if you had to power a ventilator from a large cylinder of compressed gas, which of the following devices would be required?

reducing valve

38
New cards

If you have to deliver medical gas to a patient from a compressed gas cylinder, which of the following devices would you select to control gas flow?

flowmeter

39
New cards

To clean a cylinder valve outlet of foreign material, what should you do?

Quickly open, then close, the valve.

40
New cards

What is the point in the respiratory track where inspired gas reaches body temperature, ambient pressure, saturated (BTPS) conditions?

isothermic saturation boundary

41
New cards

Which of the following is FALSE about the isothermic saturation boundary (ISB)?

Above the ISB, temperature and humidity increase during exhalation.

42
New cards

What is the primary goal of humidity therapy?

maintain normal physiologic conditions

43
New cards

Indications for warming inspired gases include all of the following except:

reducing upper airway inflammation or swelling

44
New cards

Which of the following inspired conditions should be maintained when delivering medical gases directly into the trachea through an endotracheal tube or a tracheotomy tube?

100% RH at 32° to 35° C

45
New cards

What device adds molecular water to gas?

humidifier

46
New cards

Factors affecting a humidifier's performance include all of the following except:

outlet size

47
New cards

What is the most important factor determining a humidifier's performance?

temperature

48
New cards

The greater the temperature of the gas, the:

more water vapor it can hold

49
New cards

All of the following are true about humidification and contact time except:

Low flows decrease and high flows increase relative humidity output.

50
New cards

Simple unheated bubble humidifiers are commonly used to humidify gases with what type of systems?

oronasal oxygen delivery

51
New cards

What is the goal of using an unheated bubble humidifier with oronasal oxygen delivery systems?

Raise the humidity of the gas to ambient levels.

52
New cards

What is the typical water vapor output of an unheated bubble humidifier?

15 to 20 mg/L

53
New cards

Increasing the flow through an unheated bubble humidifier has which of the following effects?

decreasing the water vapor content

54
New cards

To protect against obstructed or kinked tubing, simple bubble humidifiers incorporate which of the following?

pressure relief valve

55
New cards

A design that increases surface area and enhances evaporation by incorporating an absorbent material partially submerged in a water reservoir that is surrounded by a heating element best describes what type of humidifier?

wick

56
New cards

Advantages of passover humidifiers include all of the following except:

They do not require heating to maintain body temperature, ambient pressure, saturated (BTPS) conditions.

57
New cards

Which type of humidifier "traps" the patient's body heat and expired water vapor to raise the humidity of inspired gas?

heat-moisture exchanger

58
New cards

heat-moisture exchangers (HMEs) are mainly used to do what?

warm and humidify gases delivered to the trachea via ventilator circuits

59
New cards

An ideal heat-moisture exchanger (HME) should have an efficiency rating of at least which of the following?

70%

60
New cards

Which of the following best defines an aerosol?

suspension of liquid or solid particles in a gas

61
New cards

The mass of aerosol particles produced by a nebulizer in a given unit time best describes which quality of the aerosol?

output

62
New cards

Which of the following describes the mass of drug leaving the mouthpiece of a nebulizer as aerosol?

emitted dose

63
New cards

Which of the following is a common method to measure aerosol particle size?

cascade impaction

64
New cards

What measure is used to identify the particle diameter, which corresponds to the most typical settling behavior of an aerosol?

mean mass aerodynamic diameter (MMAD)

65
New cards

What measure is used to describe the variability of particle diameters in an aerosol?

GSD

66
New cards

Most nebulizers used in respiratory care produce which type of aerosol suspension?

heterodisperse

67
New cards

What is the retention of aerosol particles resulting from contact with the respiratory tract mucosa called?

deposition

68
New cards

What is the primary mechanism for deposition of large, high-mass particles (greater than 5 μm) in the respiratory tract?

inertial impaction

69
New cards

Where do most aerosol particles in the 5- to 10-μm range deposit?

upper airways

70
New cards

What is the primary mechanism for central airway deposition of particles in the 1- to 5-μm range?

sedimentation

71
New cards

Where do most aerosol particles in the 1- to 5-μm range deposit?

central airways

72
New cards

Which of the following techniques will increase aerosol deposition by sedimentation in the lungs?

10-second breath-hold

73
New cards

What term describes the primary mechanism for deposition of small particles?

Brownian diffusion

74
New cards

What is the primary fate of inhaled aerosol particles that are between 1 and 0.5 μm?

Most are cleared during exhalation.

75
New cards

All of the following drugs or drug categories have been associated with increased airway resistance and bronchospasm during aerosol administration except:

albuterol

76
New cards

Immediately after firing, the aerosol particles produced by most metered-dose inhalers are about how large?

35 μm

77
New cards

Most of the spray generated by the majority of metered-dose inhalers consists of which of the following?

propellant

78
New cards

When fired inside the mouth, what percentage of the drug dose delivered by a simple metered-dose inhaler (MDI) deposits in the oropharynx?

about 80%

79
New cards

A patient with an acute exacerbation of asthma is not responding to the standard dose and frequency of an aerosolized bronchodilator and is now receiving small-volume jet nebulizer (SVN) therapy every 30 minutes. Which of the following would you recommend to the patient's physician at this time?

Consider continuous nebulization of the drug.