1/31
Looks like no tags are added yet.
Controls
Bleed Air | Supplies hot, pressurized air |
Air Conditioning | Controls cabin & flight deck temperature |
Pressurization | Controls cabin altitude |
Cabin Differential Pressure Limits
Maximum cabin differential pressure (relief valves) | 9.1 PSI |
Takeoff & Landing (placard) | 0.125 PSI |
AFM equivalent | 236 ft below airport pressure altitude |
Air Conditioning Pack – HIGH Restrictions
❌ T/O, Approach, Landing — except Fire/Smoke checklists
Systems Using Bleed Air (7)
Aspirated TAT (Total Air Temperature) probe
Hydraulic reservoir pressurization
Engine starting
Water tank pressurization
Air conditioning / pressurization
Wing & engine thermal anti-icing
NGS (Nitrogen Generation System) — uses bleed air to produce nitrogen-enriched air.
Bleed users = 7: TAT | Hydraulics | Start | Water | AC/Pressurization | Anti-ice | NGS.
Bleed Air Pressure Sources
5th-stage: Low-pressure compressor.
9th-stage: High-pressure compressor.
Bleed sources: 5th = Low | 9th = High.
APU / Engine Bleed Interaction
With APU + Engine Bleed Air valves OPEN and engines at IDLE:
APU bleed may back-pressure the 9th-stage modulating & shutoff valve.
This causes the 9th-stage valve to CLOSE ❌.
APU + Engine bleed OPEN at IDLE: 9th-stage valve may CLOSE.
Minimum Air Pressure
Engine Crossbleed (X-Bleed) Start | 30 PSI |
External Air Cart | 20 PSI duct pressure |
X-Bleed start: 30 PSI | Air Cart: 20 PSI.
External Air Cart Use
APU → Left Pack | Air Cart → Right Pack
Ground Conditioned Air ⚠
Before connecting Ground Conditioned Air:
PACK switches must be OFF ❌.
Operating packs while ground conditioned air is connected can damage them.
Bleed Air – Controls & Indicators
1. DUAL BLEED 🟠
Illuminates when:
APU Bleed Valve OPEN ✅, and
ENG 1 BLEED ON ✅, or
ENG 2 BLEED ON ✅ + Isolation Valve OPEN ✅.
Action: Thrust limited to IDLE while illuminated.
2. WING–BODY OVERHEAT 🔴
Indicates overheat from a bleed-air duct leak.
LEFT light (5) | RIGHT light (3) |
|---|---|
Left Inboard Wing LE | Right Inboard Wing LE |
Keel Beam | Right Engine Strut |
Left Engine Strut | Right Air Conditioning Bay |
Left Air Conditioning Bay | |
APU Bleed Air Duct |
3. BLEED TRIP OFF 🟠
Excessive engine bleed-air temperature or pressure.
Related Engine Bleed Air Valve closes automatically ❌.
Requires TRIP RESET after fault is corrected.
4. TRIP RESET Switch
Push (only if fault condition is corrected):
Resets BLEED TRIP OFF, PACK, or ZONE TEMP lights.
Reopens the related:
Engine Bleed Air Valve, or
Pack Valve, or
Trim Air Modulating Valve.
Lights remain illuminated until reset.
5. ISOLATION VALVE Switch ⚡ (AC)
3 positions: CLOSE – AUTO – OPEN
Monitors switch position, NOT actual valve position.
Position | Operation |
|---|---|
CLOSE ❌ | Closes Isolation Valve. |
AUTO 🔄 | Closes when both Engine BLEED switches are ON and both PACK switches are AUTO or HIGH. |
Opens automatically if either Engine BLEED switch or either PACK switch is OFF. | |
OPEN ✅ | Opens Isolation Valve. |
Quick Memory 🧠
DUAL BLEED: APU + Engine bleed → IDLE thrust.
WING–BODY: Left = 5 zones; Right = 3 zones.
BLEED TRIP OFF: High temp/pressure → valve closes → correct fault → TRIP RESET.
TRIP RESET: Resets lights + reopens related valve.
ISOLATION: CLOSE = closed | AUTO = automatic logic | OPEN = open.
AUTO closes: Both ENG BLEED ON + both PACK AUTO/HIGH.
AUTO opens: Either ENG BLEED OFF or either PACK OFF.
Supplementary – Bleed Air Operations
1. Isolated Pack Operation During Engine Start
- Used to improve cabin air quality between starting the 1st and 2nd engines.
2. Unpressurized Takeoff & Landing – “No APU”
- No Engine Bleed takeoff or landing when:
APU is inoperative, or
APU is operative but not supplying bleed air.
3. No Engine Bleed Takeoff & Landing – “APU Operating”
No Engine Bleed takeoff or landing with APU operating.
Purpose: More engine power → better performance.
Before T/O – “C” Pattern
R PACK → AUTO
Isolation Valve → CLOSE ❌
L PACK → AUTO
ENG 1 BLEED → OFF ❌
APU BLEED → ON ✅
ENG 2 BLEED → OFF ❌
After T/O – Reverse “C” Pattern
ENG 2 BLEED → ON ✅
APU BLEED → OFF ❌
ENG 1 BLEED → ON ✅
L PACK → AUTO
Isolation Valve → AUTO
R PACK → AUTO
Notes:
If Anti-Ice is required during taxi → configure for No Engine Bleed T/O just before takeoff.
If Anti-Ice is NOT required during taxi → configure just after engine start.
4. Hot Weather Operation
- Ground operation when OAT (Outside Air Temperature) > +40°C.
Quick Memory 🧠
Isolated Pack: Better cabin air between engine starts.
No APU: APU unavailable / not supplying bleed.
APU Operating: No Engine Bleed T/O → more engine power.
Before T/O: C pattern = R Pack → Isolation → L Pack → ENG 1 → APU → ENG 2.
After T/O: Reverse C = ENG 2 → APU → ENG 1 → L Pack → Isolation → R Pack.
Anti-Ice taxi: Required → configure just before T/O; not required → just after engine start.
Hot weather: Ground OAT above +40°C.
Conditioned Air Distribution
1. Conditioned Air Distribution
Area | Air supply |
|---|---|
Flight Deck | Left Pack |
Passenger Cabin | Right Pack + excess air from Left Pack + recirculated air |
- All air combines in the Mix Manifold.
2. Pack Air Distribution
Left Pack: Supplies Flight Deck; excess air goes to Mix Manifold.
Right Pack: Normally supplies Mix Manifold only.
3. Temperature Control Zones
Three independent zones:
Flight Deck (CONT CAB)
Forward Cabin (FWD CAB)
Aft Cabin (AFT CAB)
- AC Zone Temperature Selector range: 18°C–30°C.
4. Pack Supply Capability
Air source | Pack supply |
|---|---|
APU | 2 Packs on ground / 1 Pack in flight |
External Air Cart | 2 Packs |
One Engine | Do NOT operate more than 1 Pack |
5. Ground Conditioned Air ⚠
Before connecting Ground Conditioned Air:
- PACK switches → OFF ❌.
Quick Memory 🧠
Left Pack → Flight Deck + excess to Mix Manifold.
Right Pack → Mix Manifold → Passenger Cabin.
3 zones: CONT CAB / FWD CAB / AFT CAB.
Temperature: 18–30°C.
APU: 2 Packs ground / 1 inflight.
Air Cart: 2 Packs.
1 Engine: Maximum 1 Pack.
Ground conditioned air: Packs OFF before connection.
Air Conditioning – Cooling Cycle & ACM
1. Cooling Cycle Operation
Bleed Air → Heat Exchanger → ACM → Water Separator → Mix Manifold
Heat Exchanger: Cools bleed air using Ram Air.
Air Cycle Machine (ACM): Refrigerates air.
Cold air combines with hot air bypassing the ACM.
High-Pressure Water Separator: Removes moisture.
Conditioned air flows to the Mix Manifold and distribution system.
2. Air Cycle Machine (ACM)
Function: Decreases air temperature by expanding air through a turbine.
3 components connected by a common shaft (high-speed rotating assembly):
Turbine
Compressor
Impeller Fan
3. Zone Temperature Control
- Trim Air quantity is regulated by 3 individual Trim Air Modulating Valves.
Quick Memory 🧠
Cooling sequence: Heat Exchanger (Ram Air) → ACM (Turbine expansion) → Hot/Cold mixing → Water Separator → Mix Manifold.
ACM: Turbine + Compressor + Impeller Fan (common shaft).
Zone control: 3 Trim Air Modulating Valve
Packs
1. Location
- Lower fuselage, between the wings.
2. Function
Deliver pressurized and conditioned air to the cabin.
Convert hot, high-pressure engine compressor air into cool, low-pressure cabin air.
3. Main Components
Ram Air Inlet
Heat Exchangers
Air Cycle Machine (ACM)
4. Pack Control Failure
- If a primary pack controller fails, the affected pack is controlled by the standby pack control in the opposite controller.
Quick Memory 🧠
Location: Lower fuselage / between wings.
Function: Hot + high pressure → Cool + low pressure cabin air.
Components: Ram Air → Heat Exchangers → ACM.
Primary controller failure: Opposite controller’s standby takes over.
RAM Air System
Provides cooling air to the Heat Exchangers.
Automatically controlled by the Packs through Ram Air Inlet Doors.
2. Ram Air Inlet Doors – Operation
Flight condition | Door position |
|---|---|
Ground / Slow Flight (Flaps Extended) | Fully OPEN ✅ for maximum cooling |
Cruise | Modulate between OPEN and CLOSED |
Inflight (Flaps Retracted) | CLOSED ❌ |
Quick Memory 🧠
RAM Air = Heat Exchanger cooling.
Ground / Slow + Flaps Extended: FULL OPEN.
Cruise: Modulating.
Inflight + Flaps Retracted: CLOSED.
Deflector Doors
Function
- Prevent slush ingestion:
Before takeoff (prior to liftoff).
After landing (after touchdown).
Operation
- Extend automatically when electrically activated by the Air/Ground (A/G) Safety Sensor.
Quick Memory 🧠
Deflector Doors = Slush protection.
Before liftoff + after touchdown.
Electrically activated by A/G Safety Sensor.
Recirculation Fans (AC Motors)
. Function
Reduce Pack load and Engine Bleed Air demand.
Draw air from Passenger Cabin + E&E Bay.
Air passes around the FWD Cargo Bay, is filtered, then recirculated to the Mix Manifold.
2. Fan Shutdown Logic – AUTO
Aircraft status | Left Fan shuts down | Right Fan shuts down |
|---|---|---|
Ground | Both Packs in HIGH | Never |
Inflight | Either Pack in HIGH | Both Packs in HIGH |
Quick Memory 🧠
Purpose: Reduce Pack load + Bleed demand.
Airflow: Cabin + E&E → Filter → Mix Manifold.
Ground: Left shuts down with both HIGH; Right never shuts down.
Inflight: Left shuts down with either HIGH; Right with both HIGH.
Electronic Controllers
1. Pack Control
Function | L Pack Controller | R Pack Controller |
|---|---|---|
Primary Pack Control | L Pack | R Pack |
RAM Air Control | L RAM Air | R RAM Air |
Standby Pack Control | R Standby | L Standby |
Cross-backup
Each controller provides standby pack control for the opposite pack.
2. Zone Control
Function | L Pack Controller | R Pack Controller |
|---|---|---|
Zone Control | AFT CABIN | FWD CABIN |
Backup | CONT CAB | Primary CONT CAB |
Quick Memory 🧠
Pack control: Own pack = Primary; opposite pack = Standby.
Zone control: L controller → AFT CABIN; R controller → FWD CABIN.
CONT CAB: L = Backup; R = Primary.