1/35
Vocabulary practice flashcards covering Kentucky plumbing statutes, administrative regulations, definitions, formulas, and technical diagrams from KRS 318 and 815 KAR Chapter 20.
Master Plumber
A person who assumes responsible charge, supervision, or direction of journeyman plumbers, apprentices, and other persons in the construction, installation, or alteration of plumbing, or who contracts, designs, plans, or superintends plumbing work.
Journeyman Plumber
A person who engages or offers to engage in the construction, installation, alteration, maintenance, repair, remodeling, removal, or replacement of plumbing under the supervision, direction, and responsibility of a master plumber.
Plumbing (KRS 318.010)
The art of installing in buildings the pipes for distributing the water supply, fixtures for using water, and drainage pipes for removing wastewater and sewage, together with fittings, appurtenances, and appliances within or adjacent to the building.
Farmstead
A farm dwelling together with other farm buildings and structures incident to the operation and maintenance of a farm situated on ten (10) acres or more of land located outside the corporate limits of a municipality.
General Liability Insurance Requirement (KRS 318.030)
Commercial general liability insurance in an amount not less than $250,000 required for any person, firm, or corporation to engage in plumbing or the trade of plumbing in Kentucky.
Air Break
A piping arrangement for a drainage system in which a drain from a fixture, appliance, or device discharges indirectly into another fixture, receptacle, or interceptor at a point below the flood level rim.
Air Gap (Drainage System)
The unobstructed vertical distance through the free atmosphere between the outlet of a waste pipe and the flood level rim of the receptacle into which it discharges.
Air Gap (Water Distribution System)
The unobstructed vertical distance through the free atmosphere between the lowest opening of any pipe or faucet supplying water to a tank, fixture, or device and the flood level rim of the receptacle.
Backflow
The flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable supply of water from any source other than its intended source, including back-siphonage and backpressure.
Back-Siphonage
The flowing back of used, contaminated, or polluted water from a plumbing fixture, vessel, or other source into a potable water supply pipe due to negative pressure in the pipe.
Critical Level (CL)
The level to which a vacuum breaker can be submerged before backflow occurs; if the marking is not displayed on the device, the bottom of the device is considered the critical level.
Dead End
A branch leading from a soil, waste, or vent pipe, building drain, or building sewer that terminates at a developed length of two (2) feet or more by means of a plug, cap, or other closed fitting.
Developed Length
The length of a pipeline measured along the center line of the pipe and its fittings.
Drainage Fixture Unit (d.f.u.)
A measure of the probable discharge into the drainage system by various types of plumbing fixtures, depending on the volume rate of discharge, operation duration, and intervals between operations (approximating 1cu ft/min on small systems).
Supply Fixture Unit (s.f.u.)
A measure of the probable hydraulic demand on the water supply by various types of plumbing fixtures, determined by volume rate of supply, operation duration, and intervals between operations.
Building Drain
The part of the lowest piping of a drainage system that receives the discharge from soil, waste, or other drainage pipes inside the walls and conveys it to the building sewer beginning two (2) feet outside the building wall.
Building Sewer
The part of the drainage system extending from the end of the building drain that conveys discharge to a public sewer, private sewer, individual sewage disposal system, or other point of disposal.
Circuit Vent
A branch vent that serves two (2) or more traps and extends from the downstream side of the highest fixture connection of a horizontal branch to the vent stack.
Loop Vent
A circuit vent that loops back to connect with a stack vent instead of connecting to a vent stack.
Common Vent
A vent connecting at the junction of two (2) fixture drains that serves as a vent for both fixture drains; also termed a dual vent.
Continuous Vent
A vertical vent that is a direct continuation of the drain to which it connects.
Durham System
A soil or waste system in which all piping consists of threaded pipe, tube, or other rigid construction using recessed drainage fittings corresponding to the piping types.
Lead (Kentucky Code Standard)
Solders and flux containing more than two-tenths (0.2%) percent lead, and wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures containing more than a weighted average of one-fourth (0.25%) percent lead.
Trap Seal
The vertical distance between the crown weir and the top of the dip of a plumbing trap.
Trap Primer
A device or piping system designed to maintain a water seal in a trap, typically installed where infrequent use would cause evaporation of the seal, such as in floor drains.
Yoke Vent
A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the stack.
Wet Vent
A vent that receives the discharge of wastes other than from water closets.
Water Heating Device
Any pressure vessel that heats, stores, and supplies potable water for domestic or commercial purposes other than for space heating.
Water Column Pressure Constant
The value of 0.434psi/ft used to calculate hydrostatic pressure at the base of a column of water (Pressure=Height in feet×0.434).
45-Degree Offset Constant
The multiplier constant of 1.414 applied to the distance between two parallel lines of pipe to calculate the center-to-center travel length of a 45∘ offset.

3-4-5 Method (Method of Making a Square)
A method to square layout lines by measuring 3ft along one board from a corner, 4ft along the perpendicular board, and verifying a hypotenuse diagonal of exactly 5ft.

Fixtures Back to Back in Battery
An arrangement of soil/waste piping where water closets and lavatories are placed on opposite sides of a partition or wall and vented into common vents leading to a vent stack.

Island Fixture Vent (Loop / Return Vent System)
A venting arrangement for island sinks consisting of a return vent looping at 45∘ angles above the flood level rim, connecting down to a horizontal foot vent and cleanout below the floor.

Grease Interceptor Venting System
A commercial fixture drainage arrangement featuring a fixture vent, a flow control fitting with a dedicated air intake vent, and an independent grease interceptor vent.

Travel Trailer Dump Station
A recreational vehicle waste disposal facility featuring a pitched concrete pad, foot-operated drain cap connected to a 4-inch sewer, washdown water tower with an atmospheric vacuum breaker, and a minimum 5ft separation to the water supply riser.

Garage Cesspool Oil Separator
A 24”×24” masonry or concrete pit separator where an un-trapped floor drain enters, featuring a 3-inch vent, an overflow/draw pipe for separated oil, and a trapped 4-inch water drain to the sewer.