New cards

What is Electrophoresis

technique used to separate macromolecules such as DNA or protein

2
New cards

what type of gels are used in gel electrophoresis

agarose

polyacrylamide Gels

3
New cards

What do the gels in electrophoresis act as

molecular sieve

4
New cards

how does electrophoresis separate charged particles

positive and negative charges

5
New cards

positively charged molecules migrate toward what

negative electrode

6
New cards

negatively charged molecules migrate toward what

positive electrode

7
New cards

Inside the electrophoresis chamber: gel

held in casting tray

contains pores that allow the particles to move very slowly toward the oppositely charged side of the chamber

8
New cards

Inside the electrophoresis chamber: comb

put in before the gel is poured in

comb removed after gel hardens

9
New cards

what do the wells of electrophoresis provide

a place to load samples

10
New cards

what is a buffer

a solution that conducts electricity

11
New cards

how do we force proteins to migrate through a gel

applying an electric field that pulls on the charged proteins

12
New cards

positively charged molecules go where

toward the cathode

13
New cards

negatively charged molecules go where

toward the anode

14
New cards

functions of proteins

enzyme catalysis

metabolic regulation

binding and transport of small molecules

gene regulation

immunological defense

cell structure

15
New cards

protein example of gene regulation

transcription factors

16
New cards

protein example of immunological defense

antibodies

17
New cards

protein example of cell structure

structural proteins in cell walls

18
New cards

what are proteins made out of

amino acids

19
New cards

what does an amino acid contain

central carbon

amino group

carboxylic acid group

R group

20
New cards

how many amino acids are there (standard)

20

21
New cards

what is responsible for a proteins negative charge at physiological pH

Glutamic acid and aspartic acid

22
New cards

what is responsible for a proteins positive charge at physiological pH

Lysine and arginine

23
New cards

what is isoelectric point

pH at which a protein has no net charge

24
New cards

will a protein migrate when its at their isoelectric point

no

25
New cards

how can the direction and extent of a proteins migration in an electric field be altered

using an acidic, neutral or alkaline buffer system during electrophoresis

26
New cards

what proteins will travel faster

proteins with more charge than others (when they are the same shape)

27
New cards

The shape of a protein is critical to what

biological function

28
New cards

will a tightly folded protein or a looser protein move faster in a gel

tightly folded

29
New cards

what are native proteins

proteins in their normal, biologically active forms

30
New cards

what can cause a protein do become denatured

detergents

extremes in pH

organic solvents

31
New cards

the molecular weight of a protein is a function of what

number and type of amino acids in the polypeptide chain

32
New cards

can a protein have more than a single polypeptide

yes- can have a single polypeptide chain or several polypeptides

33
New cards

what can effect the electrophoretic migration rates of proteins

amount and sign of charge

size and shape of native protein

34
New cards

the most abundant protein in human serum

albumin

35
New cards

what protein has one of the fastest migration rates

albumin

36
New cards

what protein has one of the slowest migration rates

Gamma Globulins

37
New cards

what do electrophoretic patterns of human serum proteins aid

the diagnosis of certain diseases

38
New cards

SDS PAGE protein electrophoresis separates proteins by what

molecular weight

39
New cards

What does SDS do in the electrophoresis process

unfolds the protein and coats it with negative charge

40
New cards

what is BME

reducing agent, breaks disulfides bonds of the protein

41
New cards

what makes the charge of a protein proportional to its molecular weight

SDS + BME

42
New cards

pH of stacking gel

6.8

43
New cards

pH of resolving gel

8.8

44
New cards

what does discontinuous mean in relation to a buffer system

the buffer in the tank is a different pH than the buffer used to make the gel

45
New cards

factors that will affect separation of protein bands

speed that the protein migrates

sensitivity to pH

voltage

ionic concentration

46
New cards

increasing the voltage with electrophoresis will cause what

proteins to migrate faster

47
New cards

increasing the ionic concentration of the buffer will do what do electrophoresis

decrease the speed of migration

48
New cards

what is chromatography

separation method

separates a number of components in a mixture

49
New cards

what is chromatography separation based on

the degrees to which the substances interact with 2 separates phases

50
New cards

what can chromatography determine

components in a mixture

51
New cards

best way to classify chromatography

according to the nature of the interaction of the mixture components with the 2 phases

52
New cards

the two phases of chromatography

mobile

stationary

53
New cards

what is the mobile phase in GC

inert gas (usually helium)

54
New cards

what pushes the mobile phase in GC

regulated pressure from a compressed gas cylinder

55
New cards

what is gas flow controlled by

software

56
New cards

mixtures in GC are usually what

organic liquids

57
New cards

what phase must mixtures be in GC

must be in the gas phase, and must be rapidly evaporated immediately upon injection

58
New cards

since the gas must rapidly evaporate in GC, what must the injection port, column, and the detector be

heated

59
New cards

GC separation of components depend on what

depend on how well the mixture components dissolve in the liquid stationary phase and the tendency of the mixture components to evaporate

60
New cards

quality of GC separation depends on what

solubility and vapor pressure

61
New cards

what is vapor pressure

substances tendency to be in the gas phase at a given temperature

62
New cards

what will happen to substances with higher vapor pressure

substances will stay in the gas phase and move through the column faster than substances with a lower vapor pressure

63
New cards

what will happen with substances of higher solubility

stay in the stationary phase (dissolve on the column) and move through the column slower than substances with low solubility

64
New cards

when should a rubber septum be changed

around every 100 injections

65
New cards

why must instrument columns be kept at an elevated temperature

to precent condensation of the sample

66
New cards

what can changing column length result in

result in better resolution due to more interaction of the sample with the stationary phase

67
New cards

what column is used the most

open tubular

68
New cards

most GC separations are what type, and what does it mean

partition type

they utilize a liquid stationary phase

69
New cards

what are the liquid phases of partition ty[es bonded to

bonded to inside wall of capillary tube

70
New cards

most capillary tubes are made of what

fused silica - a highly pure synthetic quartz material

71
New cards

outside capillary tubing is coated with what

polyimide material that gives the column an amber tint

72
New cards

how is the inside surface of stationary phase treated

silylation process that activates the surface of the column by exposing silanol groups

73
New cards

what does the stationary phase bond to

silicon of the silanol group

74
New cards

in a packed column, the liquid stationary phase is bonded to what

to the surface of a solid substrate called diatomaceous earth

75
New cards

why is it important to control temperature of GC

separation depends on vapor pressure and solubility

76
New cards

for simple separations, what temperature method is acceptable

isothermal

77
New cards

peaks are proportionate to what

proportionate to the amount of analyte present

78
New cards

FID is sensitive to what

hydrocarbons, organic compounds

79
New cards

what gas is needed to fuel FID

H gas

80
New cards

what is the universal detector

thermal conductivity detector

81
New cards

what does thermal conductivity detect

any component other than the carrier gas

82
New cards

what is referred to as the mobile phase

carrier gas

83
New cards

response factor

size of peak/ quantity of pure sample injected

84
New cards

quantity of analyte

size of peak=response factor

85
New cards

% of analyte

quantity of analyte/total quantity injected

86
New cards

what does an internal standard serve as

reference for peak size measurements

87
New cards

what is fronting or tailing peak due to

poor injections

88
New cards

changes in the carrier gas flow rate

leaks in injection port

low pressure from an empty or almost empty gas tank

faulty gas pressure

89
New cards

changes in temp

faulty temp controller

improperly set temp program

too short cool down

column overload

90
New cards

causes or irregular spikes

detector contamination

interference from electrical equipment

91
New cards

solution to unexpected peaks

do a bake out

92
New cards

factors that affect sample separation

boiling point

polarity

temp

affinity of sample for column

carrier gas flow rate

length of column

93
New cards

is there sample interaction with mobile phase of GC

no

94
New cards

is there sample interaction with mobile phase with HPLC

yes

95
New cards

which chromatography design has a septum

GC

96
New cards

GC - heated or no

heated

97
New cards

HPLC temp

room temp

98
New cards

what can make up the mobile phase HPLC

acetonitrile

methanol

water

99
New cards

what is the HPLC mobile phase contained in

glass bottle w vented cap

100
New cards

how is the mobile phase pumped in HPLC

vacuum