1/123
Looks like no tags are added yet.
What is Electrophoresis
technique used to separate macromolecules such as DNA or protein
what type of gels are used in gel electrophoresis
agarose
polyacrylamide Gels
What do the gels in electrophoresis act as
molecular sieve
how does electrophoresis separate charged particles
positive and negative charges
positively charged molecules migrate toward what
negative electrode
negatively charged molecules migrate toward what
positive electrode
Inside the electrophoresis chamber: gel
held in casting tray
contains pores that allow the particles to move very slowly toward the oppositely charged side of the chamber
Inside the electrophoresis chamber: comb
put in before the gel is poured in
comb removed after gel hardens
what do the wells of electrophoresis provide
a place to load samples
what is a buffer
a solution that conducts electricity
how do we force proteins to migrate through a gel
applying an electric field that pulls on the charged proteins
positively charged molecules go where
toward the cathode
negatively charged molecules go where
toward the anode
functions of proteins
enzyme catalysis
metabolic regulation
binding and transport of small molecules
gene regulation
immunological defense
cell structure
protein example of gene regulation
transcription factors
protein example of immunological defense
antibodies
protein example of cell structure
structural proteins in cell walls
what are proteins made out of
amino acids
what does an amino acid contain
central carbon
amino group
carboxylic acid group
R group
how many amino acids are there (standard)
20
what is responsible for a proteins negative charge at physiological pH
Glutamic acid and aspartic acid
what is responsible for a proteins positive charge at physiological pH
Lysine and arginine
what is isoelectric point
pH at which a protein has no net charge
will a protein migrate when its at their isoelectric point
no
how can the direction and extent of a proteins migration in an electric field be altered
using an acidic, neutral or alkaline buffer system during electrophoresis
what proteins will travel faster
proteins with more charge than others (when they are the same shape)
The shape of a protein is critical to what
biological function
will a tightly folded protein or a looser protein move faster in a gel
tightly folded
what are native proteins
proteins in their normal, biologically active forms
what can cause a protein do become denatured
detergents
extremes in pH
organic solvents
the molecular weight of a protein is a function of what
number and type of amino acids in the polypeptide chain
can a protein have more than a single polypeptide
yes- can have a single polypeptide chain or several polypeptides
what can effect the electrophoretic migration rates of proteins
amount and sign of charge
size and shape of native protein
the most abundant protein in human serum
albumin
what protein has one of the fastest migration rates
albumin
what protein has one of the slowest migration rates
Gamma Globulins
what do electrophoretic patterns of human serum proteins aid
the diagnosis of certain diseases
SDS PAGE protein electrophoresis separates proteins by what
molecular weight
What does SDS do in the electrophoresis process
unfolds the protein and coats it with negative charge
what is BME
reducing agent, breaks disulfides bonds of the protein
what makes the charge of a protein proportional to its molecular weight
SDS + BME
pH of stacking gel
6.8
pH of resolving gel
8.8
what does discontinuous mean in relation to a buffer system
the buffer in the tank is a different pH than the buffer used to make the gel
factors that will affect separation of protein bands
speed that the protein migrates
sensitivity to pH
voltage
ionic concentration
increasing the voltage with electrophoresis will cause what
proteins to migrate faster
increasing the ionic concentration of the buffer will do what do electrophoresis
decrease the speed of migration
what is chromatography
separation method
separates a number of components in a mixture
what is chromatography separation based on
the degrees to which the substances interact with 2 separates phases
what can chromatography determine
components in a mixture
best way to classify chromatography
according to the nature of the interaction of the mixture components with the 2 phases
the two phases of chromatography
mobile
stationary
what is the mobile phase in GC
inert gas (usually helium)
what pushes the mobile phase in GC
regulated pressure from a compressed gas cylinder
what is gas flow controlled by
software
mixtures in GC are usually what
organic liquids
what phase must mixtures be in GC
must be in the gas phase, and must be rapidly evaporated immediately upon injection
since the gas must rapidly evaporate in GC, what must the injection port, column, and the detector be
heated
GC separation of components depend on what
depend on how well the mixture components dissolve in the liquid stationary phase and the tendency of the mixture components to evaporate
quality of GC separation depends on what
solubility and vapor pressure
what is vapor pressure
substances tendency to be in the gas phase at a given temperature
what will happen to substances with higher vapor pressure
substances will stay in the gas phase and move through the column faster than substances with a lower vapor pressure
what will happen with substances of higher solubility
stay in the stationary phase (dissolve on the column) and move through the column slower than substances with low solubility
when should a rubber septum be changed
around every 100 injections
why must instrument columns be kept at an elevated temperature
to precent condensation of the sample
what can changing column length result in
result in better resolution due to more interaction of the sample with the stationary phase
what column is used the most
open tubular
most GC separations are what type, and what does it mean
partition type
they utilize a liquid stationary phase
what are the liquid phases of partition ty[es bonded to
bonded to inside wall of capillary tube
most capillary tubes are made of what
fused silica - a highly pure synthetic quartz material
outside capillary tubing is coated with what
polyimide material that gives the column an amber tint
how is the inside surface of stationary phase treated
silylation process that activates the surface of the column by exposing silanol groups
what does the stationary phase bond to
silicon of the silanol group
in a packed column, the liquid stationary phase is bonded to what
to the surface of a solid substrate called diatomaceous earth
why is it important to control temperature of GC
separation depends on vapor pressure and solubility
for simple separations, what temperature method is acceptable
isothermal
peaks are proportionate to what
proportionate to the amount of analyte present
FID is sensitive to what
hydrocarbons, organic compounds
what gas is needed to fuel FID
H gas
what is the universal detector
thermal conductivity detector
what does thermal conductivity detect
any component other than the carrier gas
what is referred to as the mobile phase
carrier gas
response factor
size of peak/ quantity of pure sample injected
quantity of analyte
size of peak=response factor
% of analyte
quantity of analyte/total quantity injected
what does an internal standard serve as
reference for peak size measurements
what is fronting or tailing peak due to
poor injections
changes in the carrier gas flow rate
leaks in injection port
low pressure from an empty or almost empty gas tank
faulty gas pressure
changes in temp
faulty temp controller
improperly set temp program
too short cool down
column overload
causes or irregular spikes
detector contamination
interference from electrical equipment
solution to unexpected peaks
do a bake out
factors that affect sample separation
boiling point
polarity
temp
affinity of sample for column
carrier gas flow rate
length of column
is there sample interaction with mobile phase of GC
no
is there sample interaction with mobile phase with HPLC
yes
which chromatography design has a septum
GC
GC - heated or no
heated
HPLC temp
room temp
what can make up the mobile phase HPLC
acetonitrile
methanol
water
what is the HPLC mobile phase contained in
glass bottle w vented cap
how is the mobile phase pumped in HPLC
vacuum