1
New cards

Which statement best describes the difference between inspection by attributes and inspection by variables?

Attributes provide go/no-go decisions; variables provide actual measured values

2
New cards

According to the Rule of 10, a measuring device should be:

Ten times more precise than tolerance

3
New cards

Whiche grade of gage block is primarlity used as a reference standard in calibration?

Grade 0.5

4
New cards

A process that repeatedly produces nearlt identical dimensions but consistently misses the target dimension is considered:

Precise but not accurate

5
New cards

Which ANSI fit class represents the tightest fot that can still be assembled by hand?

Class 4 Snug Fit

6
New cards

Standard measuring temperture for precision inspection is:

68F (20C)

7
New cards

Which istrument is specifically designed for highly accurate three-dimensional measurements?

Coordinate Measuring Machine (CMM)

8
New cards

Which inspection system is generally indpendent of ambient lighting conditions?

Laser Scanning System

9
New cards

(True or False) Standardization is important primarily because it reduces manufacturing costs and allows interchangeable parts

True

10
New cards

(True or False) The least material condition (LMC) represents a shaft at its largest permitted diameter

False

11
New cards

(True or False) Gage blocks are commonly calibrated using light-beam interferometry

True

12
New cards

(True or False) A no-go plug gage should freely enter a properly sized hole

False

13
New cards

(True or False) Laser scanning is a contact measurement method

False

14
New cards

The intentional difference between the diamensions of mating parts is called the…

Allowance

15
New cards

The ability of a measuring device to maintain calibration over time is known as… or …

Stability, drift

16
New cards

The smallest change detectable by a measuring instrument is its…

Resolution

17
New cards

In a normal distribustion, approximately ….% of all observations fall within +- 3 standard deviations

99.73