1/21
What do aerobic treatment units do?
Treat wastewater by mechanically bringing it into direct contact with air
Where does pretreatment occur for an ATU?
a single compartment septic tank
What must an ATU possess to notify the owner of failure?
an audible/visible alarm on separate circuits
How far away must you be able to hear and see the alarm for an ATU?
50 feet
ATUs must have what with information about the unit?
2 data plates
Where should the data plates on an ATU be located?
front of the electrical control box
tank, aeration equipment assembly, or riser that is often accessed for maintenance
What information should be on the ATU’s data plates?
manufacturer name/address
model number
serial number
daily hydraulic capacity
system classification
Instructions for unit service of an ATU must be located where?
near the failure signal
The owner of an ATU system must have an initial service policy of how long?
3 years/6 inspections
After the initial service policy, what must the owner of the ATU system do?
obtain an extended service policy or insure that equivalent maintenance and repair service is provided for the life of the system
Drip emitter systems are preceded by what?
an ATU
The dosing chamber for a drip emitter system must have what?
an audible/visible alarm
Drip emitter systems must be equipped to detect what?
10% change in flow rate
force main break
emitter clogging
field line leaks
flush valve failure
When are drain backs required for a drip emitter system?
when slopes exceed 5%
How far apart are emitter lines, typically?
1-2 feet
On slopes exceeding 20%, how far apart are the emitter lines?
3 feet
The filtration system a drip emitter system must be what?
self-cleaning with a backwash line to the treatment unit
Individual emitter lines may have a variance of what?
6 inches
Where should emitter lines be installed?
root zone
8-12 inches from ground surface
How often should the distribution lines be automatically flushed?
bi-monthly
What is the minimum distance between the drip irrigation system and the water table/impervious layer?
12 inches
For a drip irrigation system, what is the maximum grease content allowed in the waste stream?
25 mg/L