1/14
Looks like no tags are added yet.
Effect on steam pipe heat conduction when the two insulating layers are interchanged
Increases. Swapping the layers lowers the total thermal resistance of the composite insulation, so heat conduction through the pipe rises.
HFC refrigerant R-134a is a long-term replacement for which refrigerant?
R-12, a CFC refrigerant that R-134a was developed to replace as a non-ozone-depleting alternative with similar properties.
Part of a combined cycle plant that usually governs ramp rate
HRSG (Heat Recovery Steam Generator), because its thick metal components and large steam and water inventory slow its thermal response.
Heat exchanger with concentric tubes and one fluid inside and one outside
Double-pipe heat exchanger, which has one fluid in the inner pipe and another in the annular space between the concentric pipes.
ASME code that covers welding qualifications for piping
ASME Section IX, which governs the qualification of welding procedures and welders.
Component that regulates steam flow to the turbine
Governor valve, which modulates the quantity of steam entering the turbine to control power output or speed.
Desirable properties of a refrigerant
Large latent heat of vaporization and low operating pressures, which reduce circulation rates, compressor size, material requirements, and energy use.
Dimensionless number that indicates the significance of internal conduction resistance
Biot number, the ratio of conductive thermal resistance inside a solid to convective thermal resistance at its surface.
Variable load in a power plant
Fluctuation in electrical demand over time, meaning the continuous changes in electricity drawn from the grid that power plants must follow.
Primary purpose of a liquid-to-suction heat exchanger in a vapor compression system
Subcool the liquid refrigerant leaving the condenser, reducing flash gas and increasing the net refrigeration effect.
Dimensionless number representing the ratio of buoyancy to viscous forces
Grashof number, the dimensionless group comparing buoyancy forces to viscous forces in natural convection.
Fan type best for handling large volumes of clean air at low pressure
Propeller fan, which moves large volumes of air efficiently against low resistance, ideal for ventilation and cooling with minimal ducting.
Effect of increasing compression ratio in SI engines
Efficiency increases. For an Otto cycle, η=1−rγ−11, so higher compression ratio r raises thermal efficiency until knock or material limits apply.
Law governing convection heat transfer
Newton's law of cooling, which states that convective heat transfer is Q=hAΔT.
Factor that increases when duct length and roughness increase
Pressure loss, which rises with longer duct length and greater roughness due to increased friction, as described by the Darcy-Weisbach equation.